Physics / Fizik
Permanent URI for this collectionhttps://hdl.handle.net/11147/6
Browse
9 results
Search Results
Other Erratum To: Mbe-Grown Cdte Layers on Gaas With In-Assisted Thermal Deoxidation(Springer Verlag, 2016) Arı, Ozan; Bilgilisoy, Elif; Özçeri, Elif; Selamet, YusufArticle Citation - WoS: 6Citation - Scopus: 5Mbe-Grown Cdte Layers on Gaas With In-Assisted Thermal Deoxidation(Springer Verlag, 2016) Arı, Ozan; Bilgilisoy, Elif; Özçeri, Elif; Selamet, YusufMolecular beam epitaxy (MBE) growth of thin (∼2 μm) CdTe layers characterized by high crystal quality and low defect density on lattice mismatched substrates, such as GaAs and Si, has thus far been difficult to achieve. In this work, we report the effects of in situ thermal deoxidation under In and As4 overpressure prior to the CdTe growth on epiready GaAs(211)B wafers, aiming to enhance CdTe crystal quality. Thermally deoxidized GaAs samples were analyzed using in situ reflection high energy electron diffraction, along with ex situ x-ray photo-electron spectroscopy (XPS) and atomic force microscopy. MBE-grown CdTe layers were characterized using x-ray diffraction (XRD) and Everson-type wet chemical defect decoration etching. We found that In-assisted desorption allowed for easier surface preparation and resulted in a smoother surface compared to As-assisted surface preparation. By applying In-assisted thermal deoxidation to GaAs substrates prior to the CdTe growth, we have obtained single crystal CdTe films with a CdTe(422) XRD rocking curve with a full-width half-maximum value of 130.8 arc-s and etch pit density of 4 × 106 cm−2 for 2.54 μm thickness. We confirmed, by XPS analysis, no In contamination on the thermally deoxidized surface.Conference Object Citation - WoS: 33Citation - Scopus: 35Effects of Physical Growth Conditions on the Structural and Optical Properties of Sputtered Grown Thin Hfo2 Films(Elsevier Ltd., 2011) Aygün, Gülnur; Cantaş, Ayten; Şimşek, Yılmaz; Turan, RaşitHfO2 thin films were prepared by reactive DC magnetron sputtering technique on (100) p-Si substrate. The effects of O2/Ar ratio, substrate temperature, sputtering power on the structural properties of HfO2 grown films were studied by Spectroscopic Ellipsometer (SE), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectrum, and X-ray photoelectron spectroscopy (XPS) depth profiling techniques. The results show that the formation of a SiOx suboxide layer at the HfO2/Si interface is unavoidable. The HfO2 thickness and suboxide formation are highly affected by the growth parameters such as sputtering power, O 2/Ar gas ratio during sputtering, and substrate temperature. XRD spectra show that the deposited films have (111) monoclinic phase of HfO 2, which is also supported by FTIR spectra. XPS depth profiling spectra shows that highly reactive sputtered Hf atoms consume some of the oxygen atoms from the underlying SiO2 to form HfO2, leaving Si-Si bonds behind. © 2010 Elsevier B.V. All rights reserved.Article Citation - WoS: 10Citation - Scopus: 11The Effects of Sb Substitution on Structural Properties in Yba 2cu 3o 7 Superconductors(Springer Verlag, 2011) Akyüz, Gönül B.; Kocabaş, Kemal; Yıldız, Aylin; Özyüzer, Lütfi; Çiftçioglu, MuhsinIn this study, the effects of partial Sb 3+ ion substitutions for the Y sites and the Cu sites on the superconducting properties of YBa 2Cu 3O y (Y123) ceramic superconductors were investigated. The samples were prepared by the conventional solid-state reaction method and the properties of the samples were investigated by means of X-ray diffraction, AC magnetic susceptibility measurements, scanning electron microscope, and energy dispersive X-ray analysis. The critical temperatures were determined to be in the range of 80-92 K for both Systems I and II. It was found that Sb-addition leads to the formation of the non-superconducting YBa 2SbO 6 phase, which has a negative effect on the critical temperature, since the highest critical temperature was measured for pure Y123. However, the increasing substitution level has a negligible effect on the X-ray diffraction analysis peak intensities of the superconducting phases. In addition, SEM images showed that Sb substitution decreases the grain size and modifies the microstructure development, which makes the samples denser.Article Citation - WoS: 82Citation - Scopus: 92Metal Ion Release From Nitrogen Ion Implanted Cocrmo Orthopedic Implant Material(Elsevier Ltd., 2006) Öztürk, Orhan; Türkan, Uğur; Eroğlu, Ahmet EminCoCrMo alloys are used as orthopedic implant materials because of their excellent mechanical and corrosion properties. However, when placed in vivo, these alloys release Co, Cr, Mo ions to host tissues, which may give rise to significant health concerns over time. Nitrogen ion implantation can be used to form protective layers on the surface of CoCrMo orthopedic alloys by modifying the near surface layers of these materials. In this study, medical grade CoCrMo alloy (IS0 5832-12) was ion implanted with 60 keV nitrogen ions to a high dose of 1.9 × 10 18 ions/cm 2 at substrate temperatures of 100, 200 and 400 °C. The N implanted layer microstructures, implanted layer phases, and thicknesses were studied by a combination of Bragg-Brentano (θ/2θ) and grazing incidence (Seeman-Bohlin) X-ray diffraction (XRD and GIXRD) and cross-sectional scanning electron microscopy (SEM). Atomic force microscopy (AFM) was used for roughness analysis of N implanted as well as as-polished surfaces. Static immersion tests were performed to investigate metal ion release into simulated body fluid (SBF) by electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma optical emission spectrometry (ICP-OES). XRD and SEM analyses indicated that the N implanted layers were ∼ 150-450 nm thick and composed of the (Co,Cr,Mo) 2+xN nitride phase and a high N concentration Co-based FCC phase, γ N depending on the substrate temperature. ETAAS analysis results showed that in vitro exposure of the N implanted surfaces resulted in higher levels of cobalt ion release into the simulated body fluid compared to the untreated, polished alloy. The higher Co release from the N implanted specimens is attributed to the nature of the implanted layer phases as well as to the rougher surfaces associated with the N implanted specimens compared to the relatively smooth surface of the untreated material. SEM analysis of N implanted and untreated specimens after immersion tests clearly indicated calcium phosphate formation on the as-polished CoCrMo alloy, indicating a degree of bioactivity of the untreated metal surface which is absent in the N implanted specimens.Article Citation - WoS: 89Citation - Scopus: 94Effects of Li Substitution in Bi-2223 Superconductors(Springer Verlag, 2008) Bilgili, Özlem; Selamet, Yusuf; Kocabaş, KemalThe effects of Li substitution on the properties of high temperature superconductor Bi 17Pb 0.3Sr 2C 2Cu 3-x Li x O y were investigated. The samples were prepared by substituting Li (x=0.00-0.20) with changing ratios by a solid state reaction method. The samples were characterized by X-ray diffraction, DC electrical resistivity, AC magnetic susceptibility, and scanning electronic microscopy (SEM). The X-ray diffraction studies were done at room temperature and the lattice constants of the material were determined by indexing all the peaks observed. This study shows that there are two coexisting phases; high-T c (2223) phase and low-T c (2212) phase. The lattice structure of the material belongs to the orthorhombic unit cell. The volume fraction was estimated from the intensities of Bi-(2223) and Bi-(2212) phases. The sample with 20 wt% of added Li showed the higher volume fraction of Bi-(2223) phase formed (81%) compared to the other samples. The DC electrical resistivity of all the samples decreased as the wt% of Li increased. Both the onset critical temperatures T c (onset) and zero electrical resistivity critical temperatures T c (R=0) of the samples were determined from the DC electrical resistivity measurements. The observed value of the onset critical T c (onset) temperature was 110 K agreeing well with the magnetic susceptibility measurements. We obtained T c onset at 112 K from AC magnetic susceptibility measurements. © 2008 Springer Science+Business Media, LLC.Article Citation - WoS: 19Citation - Scopus: 19Biofilm Formation by Staphylococcus Epidermidis on Nitrogen Ion Implanted Cocrmo Alloy Material(John Wiley and Sons Inc., 2007) Öztürk, Orhan; Sudağıdan, Mert; Türkan, UğurStaphylococcus epidermidis is the primary cause of medical device-related infections due to its adhesion and biofilm forming abilities on biomaterial surfaces. For this reason development of new materials and surfaces to prevent bacterial adhesion is inevitable. In this study, the adhesion of biofilm forming S. epidermidis strain YT-169a on nitrogen (N) ion implanted as well as on as-polished CoCrMo alloy materials were investigated. A medical grade CoCrMo alloy was ion implanted with 60 keV N ions to a high dose of 1.9 × 10 18 ions/cm2 at substrate temperatures of 200 and 400°C. The near-surface implanted layer crystal structures, implanted layer thicknesses, and roughnesses were characterized by XRD, SEM and AFM. The number of adherent bacteria on the surfaces of N implanted specimens was found to be 191 × 106 CFU/cm2 for the 200°C and 70 × 106 CFU/cm2 for the 400°C specimens compared to the as-polished specimen (3 × 106 CFU/cm2). The adhesion test results showed that S. epidermidis strain YT-169a adhere much more efficiently to the N implanted surfaces than to the as-polished CoCrMo alloy surface. This was attributed mainly to the rougher surfaces associated with the N implanted specimens in comparison with the relatively smooth surface of the as-polished specimen.Article Citation - WoS: 16Citation - Scopus: 18Microstructural, Mechanical, and Corrosion Characterization of Nitrogen-Implanted Plastic Injection Mould Steel(Elsevier Ltd., 2005) Öztürk, Orhan; Onmuş, Ortaç; Willeamson, Don L.Nitrogen-ion implantation can be used to improve the wear and corrosion behaviour of moulds for plastic injection by modifying the near-surface layers of these materials. In this study, an FeCr ferritic stainless steel (X36CrMo17, similar to AISI-420F) was ion implanted with 85 keV nitrogen ions to low and high doses of 2×1017 and 1×1018 ions/cm2 at a substrate temperature <200 °C in an industrial implantation facility. The N-implanted layer microstructures, thicknesses, and hardnesses were studied by a combination of symmetric and grazing incidence X-ray diffraction (XRD and GIXRD), conversion electron Mössbauer spectroscopy (CEMS), cross-sectional scanning electron microscopy (SEM), and nanohardness measurements. The friction, wear, and corrosion behaviour were investigated by a pin-on-disc tribo tester and a salt spray corrosion analysis method. The XRD, CEMS, and SEM analyses indicate that the N-implanted layers are ∼0.05-0.08 μm thick and are composed of ε-(Fe,Cr,Mn)2+xN with paramagnetic and magnetic characteristics. The treated layer shows nearly two times better corrosion resistance than does the substrate. The wear and nanohardness measurements indicate that the wear behaviour and the N-implanted layer hardness are dose dependent and the latter is increased by more than a factor of 1.6 for the high-dose implanted specimen in comparison with that of the substrate material.Article Citation - WoS: 15Citation - Scopus: 15Microstructural, Mechanical, and Corrosion Characterization of Plasma-Nitrided Plastic Injection Mould Steel(Elsevier Ltd., 2005) Öztürk, Orhan; Onmuş, Ortaç; Willeamson, Don L.Plasma nitriding can be used to improve wear and corrosion behaviour of moulds for plastic injection by modifying the near-surface layers of these materials. In this study, a ferritic stainless steel (X36CrMo17) was plasma nitrided at 520-540 °C for 15-18 h under various gas mixtures of N2+H2 in an industrial nitriding facility. The nitrided layer microstructures, thicknesses, and strengths were studied by X-ray diffraction (XRD), conversion electron and X-ray Mössbauer spectroscopies (CEMS and CXMS), cross-sectional scanning electron microscopy (SEM), and cross-sectional nanohardness measurements. The corrosion behaviour was investigated by a salt spray method. Combined Mössbauer, XRD, and SEM analyses demonstrate that (Fe,Cr,Mn)-nitrides, the ε- and γ′-nitrides, the Fe3C-like carbide, and CrN are distributed in the top nitrided layers of several micron thickness. The CEMS and CXMS analyses clearly show the nearly complete decomposition of the surface and deeper layers into phase separated mixtures of pure bcc-Fe, (Fe,Cr,Mn)-nitrides, and CrN. The nitriding conditions with the gas composition N2/H2=1 produces the thickest nitrided layer (∼135 μm) with enhanced corrosion protection. The nanohardness of the surface layers is found to be plateau-shaped and increased by about a factor of three in comparison to that of the substrate material.
