Environmental Engineering / Çevre Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4321
Browse
5 results
Search Results
Book Part Arsenic Removal by Electrocoagulation(Wiley, 2022) Gören, Ayşegül Yağmur; Kobya, MehmetBecause of the toxic impacts on human health, the arsenic (As) limit value in drinking water was decreased from 50 to 10 ?g l-1 by the relevant authorities (WHO 1993; US EPA 2001). In this case, the problem of As pollution in natural water resources used for drinking water has grown even more and turned into a global crisis. According to reports in many parts of the world, over about 230 million people appear to be affected by high arsenic concentrations in groundwater. In this case, it turned out that there was a great need for cost-effective and environmentally friendly technologies from drinking water sources. One of the emerging water treatment technologies in recent years is electrocoagulation (EC) and it has been seen that it is effective in treating As (>99%) from water and eliminates some of the disadvantages of other conventional treatment processes. EC method includes electro-oxidation of anode electrode materials (iron and aluminum) and in situ production of coagulant agents. From groundwater resources with As content of 5-1000 ?g l-1, As removal efficiencies and operating costs (OCS) of EC technology using iron (Fe) and aluminum (Al) anodes were 85.0-99.9% and 0.0020-1.04 US$ m-3, respectively. Different types (plate, scrap, rod, and ball) of electrodes were used for As removal with the EC process, and it was observed that Fe electrodes or Fe-Al hybrid electrodes performed better in As removal. In addition, it has been determined that arsenate (As(V)) removal is more effective than arsenite (As(III)). A significant quantity of As(III) is oxidized in the EC process, resulting in precipitation, adsorption, and metal-oxy hydroxylic complex reactions. EC process has a lower OC to achieve As removal below the permissible WHO value compared to conventional treatment processes, accomplishing it as a further applicable option for As removal. © 2023 John Wiley & Sons, Inc.Article Citation - WoS: 8Citation - Scopus: 8Removal of Arsenic in Groundwater From Western Anatolia, Turkey Using an Electrocoagulation Reactor With Different Types of Iron Anodes(Elsevier, 2022) Kobya, Mehmet; Dolaz, Mustafa; Özaydın Şenol, Burcu; Gören, Ayşegül YağmurElectrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 μg L−1, GW-2: 1132.1 μg L−1, and GW-3: 52, 000 μg L−1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 μg L−1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m−3 for ball anodes, >99.9%, 100 min and 0.0813 $ m−3 for plate anodes, >99.9%, 80 min and 0.0815 $ m−3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.Article Citation - WoS: 47Citation - Scopus: 57Arsenic Removal From Groundwater Using an Aerated Electrocoagulation Reactor With 3d Al Electrodes in the Presence of Anions(Elsevier, 2021) Gören, Ayşegül Yağmur; Kobya, MehmetCo-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x1: 1–10 mg L?1), silica (x2: 20–80 mg L?1), bicarbonate (x3: 130–670 mg L?1), fluoride (x4: 2–10 mg L?1), boron (x5: 5–10 mg L?1), and operating time (x6: 8–22 min) on desired responses. The specified responses were effluent arsenic concentration (Cf,As), removal efficiency of arsenic (Re), consumptions of energy and electrode (ENC and ELC), operational cost (OC), and adsorption capacity (qe). The optimum operating parameters predicted using BBD were found to be x1: 1.0 mg L?1, x2: 26.0 mg L?1, x3: 651.5 mg L?1, x4: 2.0 mg L?1, x5: 9.9 mg L?1, and x6: 10.5 min considering highest removal efficiency of arsenic and lowest operational cost. Under these operating conditions, the experimental values of Cf,As, Re, ENC, ELC, OC, and qe were found to be 2.82 ?g L?1, 98.6%, 0.411 kWh m?3, 0.0124 kg m?3, 0.098 $ m?3, and 17.65 ?g As (mg Al)?1, respectively. Furthermore, mathematical modelling was conducted using quadratic regression model and response surface analysis was performed to understand the relationship between independent parameters and responses. © 2020 Elsevier LtdArticle Citation - WoS: 4Citation - Scopus: 5Combined Influence of Some Cations on Arsenic Removal by an Air-Injection Ec Reactor Using Aluminum Ball Electrodes(Desalination Publications, 2020) Gören, Ayşegül Yağmur; Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Öncel, Mehmet SalimCombined effects of some cations such as calcium (Ca2+), iron (Fe2+), manganese (Mn2+), and magnesium (Mg2+) and operating time on the removal of arsenic by air-injected electrocoagulation (EC) reactor with aluminum (Al) ball electrodes were investigated. The operating conditions were optimized with the Box-Behnken design of response surface methodology (RSM). The response variables were selected from the program as removal efficiency, residual arsenic concentration, energy consumption and operating cost (OC) in the EC process. A total of 46 experimental run was performed. The removal efficiency of arsenic increased with an increase in iron concentration (0.5-4.5 mg/L). The rest of the cations showed no noticeable effect on arsenic removal efficiency. The maximum arsenic removal efficiency and minimum OC at the optimum operating conditions (C-Ca: 305 mg/L, C-Mg: 42 mg/L, C-Fe: 3.3 mg/L, C-Mn: 2.34 mg/L, initial pH of 7.5 applied current of 0.15 A, Al ball size of 7.5 mm, 5.0 cm of Al ball anodes height in the EC reactor, air-fed rate of 6.0 L/min and t(EC): 16.83 min) in the EC process were 99.9% and 0.0332 $/m(3) for initial arsenic concentration of 200 mu g/L, respectively. The removal mechanism of As(III) by EC seems to be oxidation of As(III) to As(V) and subsequent removal by adsorption/complexation with aluminum hydroxides generated in the process. The results showed that the air-injected EC reactor can be used effectively for arsenic and hardness removal simultaneously from real groundwater sources.Article Citation - WoS: 3Citation - Scopus: 6Optimization of Some Cations for Removal of Arsenic From Groundwater by Electrocoagulation Process(Gheorghe Asachi Technical University of Iasi, 2018) Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet SalimThis study dealt with investigation of arsenic removal from groundwater using electrocoagulation (EC) method in a batch mode by the Box-Behnken experimental design method. Effects of some cations like Ca, Fe, Mg, Mn and operating time on the removal were explored by an air injected EC reactor. The combined effects of these variables were analyzed by the quadratic model for predicting the highest removal efficiency of arsenic from groundwater. The arsenic removal efficiency was found to be dependent on increase with operating time and concentrations of Ca, Mg, Fe and lower concentration of Mn. When operating variables were considered as minimum operating cost and maximum removal efficiency, the optimum operating parameters were determined to be 132 mg/L of CCa, 55 mg/L of CMg, 4.5 mg /L of CFe, 4.5 mg/L of CMn and operating time of 3 min to meet the target concentration of <10 μg/L. Values of removal efficiency and operating cost at the optimum conditions were 95.1% and 0.041 $/m3.
