Environmental Engineering / Çevre Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4321

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 26
    Citation - Scopus: 34
    Arsenite Removal From Groundwater in a Batch Electrocoagulation Process: Optimization Through Response Surface Methodology
    (Taylor & Francis, 2019) Şık, Emrah; Gören, Ayşegül Yağmur; Demirbaş, Erhan; Kobya, Mehmet; Öncel, Mehmet Salim
    In this study, influences of seven process variables such as initial pH (pH(i)), applied current (i), operating time (t(EC)), initial As(III) concentration (C-o), diameter of Fe ball anode (d(p)), column height in the electrocoagulation (EC) reactor (h) and airflow rate (Q(air)) for removal of As(III) from groundwater by a new air-fed fixed-bed EC reactor were evaluated with a response surface methodology (RSM). The proposed quadratic model fitted very well with the experimental data for the responses. The removal efficiencies and operating costs were determined to be 99% and 0.01 $/m(3) at the optimum operating conditions (a pH(i) of 8.5, 0.05 A, 4.94 min, d(p) of 9.24 mm, h of 7.49 cm, Q(air) of 9.98 L/min for 50 mu g/L). This study clearly showed that the RSM in the EC process was a very suitable method to optimize the operating conditions at the target value of effluent As(III) concentration (10 mu g/L) while keeping the operating cost to minimal and maximize the removal efficiency.
  • Article
    Citation - WoS: 3
    Citation - Scopus: 6
    Optimization of Some Cations for Removal of Arsenic From Groundwater by Electrocoagulation Process
    (Gheorghe Asachi Technical University of Iasi, 2018) Kobya, Mehmet; Şık, Emrah; Demirbaş, Erhan; Gören, Ayşegül Yağmur; Öncel, Mehmet Salim
    This study dealt with investigation of arsenic removal from groundwater using electrocoagulation (EC) method in a batch mode by the Box-Behnken experimental design method. Effects of some cations like Ca, Fe, Mg, Mn and operating time on the removal were explored by an air injected EC reactor. The combined effects of these variables were analyzed by the quadratic model for predicting the highest removal efficiency of arsenic from groundwater. The arsenic removal efficiency was found to be dependent on increase with operating time and concentrations of Ca, Mg, Fe and lower concentration of Mn. When operating variables were considered as minimum operating cost and maximum removal efficiency, the optimum operating parameters were determined to be 132 mg/L of CCa, 55 mg/L of CMg, 4.5 mg /L of CFe, 4.5 mg/L of CMn and operating time of 3 min to meet the target concentration of <10 μg/L. Values of removal efficiency and operating cost at the optimum conditions were 95.1% and 0.041 $/m3.