Conservation and Restoration of Cultural Heritage / Kültür Varlıklarını Koruma ve Onarım
Permanent URI for this collectionhttps://hdl.handle.net/11147/23
Browse
4 results
Search Results
Article Citation - WoS: 3Citation - Scopus: 5Helenistik Kulelerde Yanal Yüke İlişkin Düzlem İçi ve Düzlem Dışı Duvar Davranışının Duvar Profilleri ve Açıklık Düzenlerine Bağlı Olarak İncelenmesi(Gazi Üniversitesi, 2020) Gençer, Funda; Turan, Mine; Aktaş, EnginDry masonry wall profiles constructed without using bonding material between blocks are encountered in different building types dated to Greek, Hellenistic and Roman periods. Depending on development of earthquake experiences, dry masonry wall profiles vary in terms of wall thickness, number of layers, relationship of layers and size, form, organization and relationship of blocks. In this study, the construction details increasing the structural strength in watch towers constructed in Hellenistic Period are aimed to be determined. This study is limited with investigation of effect of wall profiles and opening organizations on in-plane and out-of-plane wall behaviors under lateral loading. Primarily, wall profiles and opening types of dry masonry towers in ancient Caria, Pamphylia and Cilicia regions, that have not lost authenticity and integrity or had information about their authentic form, were documented. By using gathered data, hypothetic towers with different wall profiles and opening types are designed. To determine in-plane and out-of-plane wall behavior of hypothetic towers, simulation of quasi-static tilt analysis based on equilibrium were carried out, and form changes at walls and collapse angles of towers were identified. Wall profile and opening properties effecting on structural strength under lateral loading were determinedd.Article Citation - WoS: 1Citation - Scopus: 2Consolidation of a Bath Ruin in an Archaeological Site(Taylor and Francis Ltd., 2022) Durmuşlar, Feyza; Turan, Mine; Yücetürk, Kutay; Aktaş, EnginThe study has focused on consolidation of a historical bath ruin in an archaeological site. Cevher Pasa Bath, which is located in Tabae archaeological site in Denizli, Turkey and dated to the 15th century, presents structural problems. The aim of the study is to propose a framework for planning consolidation of the ruins of Cevher Pasa Bath so that conservation work regarding similar masonry ruins in archaeological sites can be guided. Thus, methods of architectural restoration and civil engineering are combined in an interdisciplinary scope. Provision of temporary shoring as an emergency intervention, consolidation and presentation of the ruin within the scope of an interdisciplinary restoration project, and monitoring of the asset within the frame of a monument management plan are suggested, respectively. Structural analysis considering stress and overturning moment checks are performed. Consolidation work includes only supporting of arch remains. Some walls of the ruin are weaker than other parts. These parts need further detailed analysis, and if necessary, further consolidation and strengthening are to be carried out. The monument management plan points out the necessity of collaboration of local and central administrations, and also non-governmental organisations.Article Citation - WoS: 1Citation - Scopus: 1Proposals for Monitoring Current Conservation Condition of Historical Masonry Buildings: Matrone Church and Çardak Han Cases;(Istanbul University Press, 2020) Durmuşlar,F.; Ipekci,E.; Turan,M.H.; Aktaş,E.The aim of this study is to transfer the international developments related to the process of diagnosis and monitoring of historical masonry structures to the national area. The method chosen is to test the recommendations made at the international level on national cases and to discuss the results obtained by comparing them. A review of preliminary studies, on-site observations, measured surveys, material characterizations, mapping and visual analysis have been carried out. An examination of structural characteristics and observed failures have also been detailed. Related risks have been evaluated with criteria developed by taking into consideration condition classes defined in the UNI EN 16096, titled Conservation of Cultural Property - Condition Survey and Report of Built Cultural Heritage. According to the defined risks and classes, priorities of interventions were determined. Two historical masonry buildings which possess characteristics of different periods and present different damage types were selected: Matrone Church in Ildiri, Çeşme, Izmir and Çardak Han in Çardak, Denizli. The condition reports of the selected buildings have been prepared. The critical points in the condition reporting of historical masonry buildings were determined: accurate comprehension of the authentic structural characteristics and related failures have priority in maintaining historical masonry structures. Identification of condition class and risk assessment of each historic masonry building should be made in accordance with a standard specific to the cases of our country, but in line with the European standards and current developments in the field of architectural restoration. Thus, it will be possible to evaluate the conservation state of our masonry assets in comparison with each other. The content and priority of interventions can be well planned with the participation of the necessary disciplines. © 2020 The authors.Article Citation - WoS: 3Citation - Scopus: 3Structural Vulnerability of Ancient Dry Masonry Towers Under Lateral Loading(Elsevier, 2020) Gençer, Funda; Hamamcıoğlu Turan, Mine; Turan, Mine; Aktaş, Engin; Aktaş, EnginUnderstanding how the original characteristics contribute to the structural behaviour of antique structures should be the initial stage of planning for conservation work. This study aims to identify the structural behaviour of dry masonry towers under lateral loadings, so that the decision-making process when determining their restoration can be adequately supported. Dry masonry towers in ancient Caria, Pamphylia, and Cilicia Regions are examined. Each of these three areas have very different seismic characteristics. A hypothetical testing process was designed by combining different characteristics from each of the towers. As a result, the characteristics affecting the structural resistance were determined as; the staggering ratio, the stone depth, the ratio between block length and height, the proportional relationship between height and length, the area, number and position of openings, and the distribution of header stones. These characteristics all interact together to determine the failure mechanism; so, understanding this interaction is critical when considering conservation. © 2020 Elsevier Ltd
