Mechanical Engineering / Makina Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4129
Browse
5 results
Search Results
Article Citation - WoS: 1Citation - Scopus: 2Emergence of Taperedducts in Vascular Designs With Laminar and Turbulent Flows(Begell House, 2014) Çetkin, ErdalHere we show that tapered ducts emerge in volumetrically bathed porous materials to decrease the resistance to the flow in laminar and turbulent flow regimes. The fluid enters the volume from one point and it is distributed to the entire volume. After bathing the volume, it is collected and leaves the volume from another point, i.e., two trees matched canopy to canopy. This paper shows that the flow architecture (i.e., design of the void spaces in a porous material) should be changed to obtain the minimum resistance to the flow as its size increases. Tapering the ducts decreases the order of the transition size, i.e., the size for changing from one construct to another to obtain the minimum pressure drop. The decrease in the pressure drop is 16% and 38% with the tapered ducts when the flow is laminar and turbulent, respectively. In addition, the volume ratios and the shape of the tapered ducts are documented. There is no design existing in nature with diameters of constant size in order to distribute and/or collect heat, fluid, and/or stress such as bones, rivers, veins, and tree branches. The emergence of the tapered ducts in designed porous materials is natural.Article Citation - WoS: 12Citation - Scopus: 11Inverted Fins for Cooling of a Non-Uniformly Heated Domain(Yıldız Teknik Üniversitesi, 2015) Çetkin, ErdalThis paper shows that the peak temperature of a non-uniformly heated region can be decreased by embedding high-conductivity tree-shaped inserts which is in contact with a heat sink from its stem. The volume fraction of the high-conductivity material is fixed, and so is the volume of the solid region. The length scale of the solid domain is L. Inside there is a cube-shaped region with length scale of 0.1L and heat production 100 times greater than the rest of the domain. The location of this hot spot was varied to uncover how its location affects the peak temperature and the design of inverted fins, i.e. highconductivity tree-shaped inserts. The volume fraction of the high-conductivity tree was varied for number of bifurcation levels of 0, 1 and 2. This showed that increasing the number of the bifurcation levels decreases the peak temperature when the volume fraction decreases. The optimal diameter ratios and optimal bifurcation angles at the each junction level are also documented. Y-shaped trees promise smaller peak temperatures than T-shaped trees. The location of the vascular tree in the z direction also affects the peak temperature when the heat generation is non-uniform. In addition, the peak temperature is minimum when z = 0.65L even though the hot spot is located on z = 0.75L.Article The Effect of Time Delay of Fluid Flow in a Vascularized Plate(MIM Research Group, 2018) Yenigün, Onur; Coşkun, Turgay; Çetkin, ErdalIn this study, we show the effect of time delay of coolant fluid flow into a vascularized plate on the peak temperature. Coolant flows along vascular channels which were embedded in a rectangular plate. Two kinds of vascular channel designs were investigated experimentally: parallel and tree-shaped. In the study, the peak temperatures were monitored and the coolant was pumped when the peak temperature reaches to 50°C, 70°C and 90°C. The performance comparison of two distinct designs is based on two criteria: the time required for the steady state condition after the coolant is pumped and the peak temperature after the steady state condition is conformed. The results show that the time required to reach steady-state condition increases as the time delay increases. The parallel and tree-shaped designs show similar performance (time required to reach steady state) with slightly improved performance in the tree-shaped design as the preset temperature for time delay increases. For instance, 4% decrease in the time required to reach steady-state with the tree-shaped design relative to the parallel design was achieved when the preset temperature for time delay is 90°C.Article Citation - WoS: 3Citation - Scopus: 4The Effect of Cooling on Mechanical and Thermal Stresses in Vascular Structures(Yıldız Teknik Üniversitesi, 2018) Çetkin, ErdalHere, we show how the vascular channel configuration and its shape affect the mechanical strength which is simultaneously subjected to heating and mechanical load. The material properties were defined as functions of temperature. The effect of channel cross-section on the coolant mass flow rate, peak temperature and peak stresses are documented. The results show that the resistances to flow of stresses and fluid is minimum with the circular channels while the resistance to the heat flow is the smallest with semi-circular channels. In addition, morphing the vascular design provides almost the smallest resistance to the heat flow with circular channels (0.3% difference in the peak temperature). This shows that even the convective resistances are the smallest with circular-cross section, overall thermal resistance is smaller in semi-circular design for the fixed fluid volume. The peak stress is smaller with hybrid design than the parallel designs for the entire pressure drop range. In addition, the effects of mechanical load, heating rate and reference temperature on the stress distribution are also documented. Furthermore, the thermal and mechanical stresses are also documented separately, and then compared with the coupled solution cases. The chief result of this paper is that for a coupled system minimizing only one of the resistance terms is not sufficient, all the resistances considered simultaneously in order to uncover the best performing design. In coupled solutions, we documented the simulation results with temperature dependent material properties and the resistances to the heat and fluid flow is affected by the mechanical deformations. In addition, the results show that the designs should be free to vary, the unexpected designs can be the best performing designs for the given parameters and constraints. Therefore, the design parameters based on the experience does not always yield the best performing designs as the objectives and constraints vary.Article Citation - WoS: 3Citation - Scopus: 5Constructal Tree-Shaped Designs for Self-Cooling(Edizioni ETS, 2016) Yenigün, Onur; Çetkin, ErdalIn this paper, we show how a plate which is subjected to a heating load can be kept under an allowable temperature. Vascular channels in which coolant fluid flows have been embedded in the plate. Two types of vascular channel designs were compared: radial and tree-shaped. The effects of channel design on the thermal performance for different volume fractions (the fluid volume over the solid volume) are documented. Changing the design from radial to tree-shaped designs decreases the order of pressure drop. Hence increase in the order of the convection coefficient is achieved. However, treeshaped designs do not bath the entire domain. Therefore, we have inserted additional branches at the uncooled regions. Then, we have compared the peak temperatures of radial, traditional tree-shaped and improved tree-shaped designs. The effect of design on the maximum temperature shows that there should be an optimum design for a distinct set of boundary conditions, and this design should be varied as the boundary conditions change. This result is in accord with the constructal law, i.e. the shape should be varied in order to minimize resistances to the flows.
