Mechanical Engineering / Makina Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4129

Browse

Search Results

Now showing 1 - 3 of 3
  • Data Paper
    Citation - WoS: 15
    Citation - Scopus: 20
    Database Covering the Prayer Movements Which Were Not Available Previously
    (Nature Publishing Group, 2023) Mihçin, Şenay; Şahin, Ahmet Mert; Alpkaya, Alican Tuncay; Alpkaya, Alican Tuncay; Tuna, Merve; Mihçin, Şenay; Can, Nuray Korkmaz; Tosun, Aliye; Şahin, Serap; 03.04. Department of Computer Engineering; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering
    Lower body implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. A database covering these diverse activities of the Eastern world is non-existent. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations with a special focus on the lower body joints. The current version of the database covers 50 volunteers for 13 different activities. The tasks are defined and listed in a table to create a database to search based on age, gender, BMI, type of activity, and motion capture system. The collected data is to be used for designing implants to allow these sorts of activities to be performed.
  • Data Paper
    Database Covering the Previously Excluded Daily Life Activities
    (2023) Mihçin, Şenay; Şahin, Ahmet Mert; Mihçin, Şenay; Alpkaya, Alican Tuncay; Tuna, Merve; Alpkaya, Alican Tuncay; Şahin, Serap; Akdeniz, Sevinç; Şahin, Serap; 03.04. Department of Computer Engineering; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering
    In biomedical engineering, implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. Although databases cover ADL for the Western population, a database covering these diverse activities of the Eastern world, specific to these populations is non-existent. To include previously excluded ADL is a key step in understanding the kinematics and kinetics of these activities. By means of developments in motion capture technologies, excluded ADL data are captured to obtain the coordinate values to calculate the range of motion and the joint reaction forces. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations. Anthropometrics are known to affect kinematics and kinetics which are also included in the collected data. The current version of the database covers 50 volunteers for 12 different activities, the database aims for 100- male and 100- female healthy volunteers as the final target including C3D and BVH file types. The tasks are defined and listed in a table to create a database to make a query based on age, gender, BMI, type of activity and motion capture system. The data is collected only from a healthy population to understand healthy motion patterns during these previously excluded ADLs. The collected data is to be used for designing implants to allow these sorts of activities to be performed without compromising the quality of life of patients performing these activities in the future.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 10
    The Computational Approach To Predicting Wear: Comparison of Wear Performance of Cfr-Peek and Xlpe Liners in Total Hip Replacement
    (Taylor & Francis, 2022) Alpkaya, Alican Tuncay; Mihçin, Şenay; Alpkaya, Alican Tuncay; Mihçin, Şenay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering
    Wear on articulating bearing surfaces is a key factor causing revision in total hip replacement (THR). Wear debris that releases particles from bearing surfaces might result in adverse soft tissue reactions requiring revision surgeries. In this study, a comprehensive computational wear model based on the Archard wear equation was performed to investigate the wear performance under a three-dimensional (3D) physiological gait cycle, mimicking a normal walking condition (5 million cycles). The study shows that the accuracy of the model is highly dependent on the mesh convergence, the wear fraction, and the scaling factor. The simulations were run to provide a vast amount of detail for the reproducibility of the work. Cobalt chromium (CoCr) on cross-linked polyethylene (XLPE) and CoCr on carbon-fiber-reinforced polyether ether ketone (CFR-PEEK) prototype models were created in silico. The volumetric wear rates for CoCr-on-XLPE were calculated as 0.2989 (Formula presented.) for CoCr head and 21.0271 (Formula presented.) for XLPE liner, while for CoCr-on-CFR-PEEK they were 0.3484 (Formula presented.) for CoCr head and 1.8476 (Formula presented.) for CFR-PEEK liner. When compared to in vivo and in vitro studies, the wear patterns of these two prototypes are consistent with those of the conventional polyethylene liners in the literature. Although the volumetric wear rate of the CFR-PEEK liner is about 11 times lower than the counterpart of XLPE in MoP implants, the wear rate of CoCr was higher when compared to its use with XLPE. Therefore, CFR-PEEK articulating against orthopa\edic metals may not be as good an alternative as XLPE, due to higher indicative metallic wear. This detailed computational wear modeling methodology could be utilized in design improvements of implants.