    Assessment of Thermal Comfort Preferences in Mediterranean Climate a University Office Building Case
    (Vinca Inst Nuclear Sci, 2018) Turhan, Cihan; Gökçen Akkurt, Gülden
    This study aims at evaluating the perceived thermal sensation of occupants with respect to thermal comfort standards, ASHRAE 55 and ISO 7730, for office buildings located in Mediterranean climate. A small office building in Izmir Institute of Technology Campus Area, Izmir, Turkey, was chosen as a case building and equipped with measurement devices to assess thermal comfort of occupants with respect to predicted mean vote and actual mean vote. Both objective and subjective measurements were conducted. The former included indoor and outdoor air temperature, mean radiant temperature, relative humidity and air velocity that were used for evaluating the thermal comfort of occupants. Oxygen concentration which can play an additional role in thermal comfort/discomfort, health and productivity of the office occupants, was also measured. Furthermore, occupants were subjected to a survey via a mobile application to obtain subjective measurements to calculate actual mean vote values. Based on objective and subjective measurements, the relationships among the parameters were derived by using simple regression analysis technique while a new combined mean vote correlation was also derived but this time by using multiple linear regression model. Neutral and comfort temperatures were obtained using indoor air temperature and actual mean vote values which were calculated from subjective measurements. The results showed that neutral temperature in the university office building was 20.9 degrees C whilst the comfort temperature range was between 19.4 and 22.4 degrees C for the heating season. By applying new comfort temperatures, energy consumption of the case building located in Mediterranean climate, can be reduced.
  • Article
    Citation - WoS: 6
    Citation - Scopus: 9
    Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone
    (Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    Most historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 7
    The Importance of Internal Heat Gains for Building Cooling Design
    (Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    This paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.