Mechanical Engineering / Makina Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4129
Browse
11 results
Search Results
Article Citation - WoS: 33Citation - Scopus: 42Thermodynamic Assessment of Downhole Heat Exchangers for Geothermal Power Generation(Elsevier, 2019) Yıldırım, Nurdan; Yıldırım, Nurdan; Parmanto, Slamet; Gökçen Akkurt, Gülden; Akkurt, Gülden Gökçen; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyDownhole heat exchanger is a device to extract heat from geothermal fluid. While it is widely used for heating purposes, its use for power generation has not been reported. The aim of this study is to examine the feasibility of power generation from a 2500 m deep existing geothermal well with high temperature gradient and insufficient flowrate by using a downhole heat exchanger. For this purpose, a thermodynamic and an economic evaluation model are developed by the use of Engineering Equation Solver software. Additionally, the parametric studies have been carried out to identify the effects of insulation, geothermal well conditions, geometry of downhole heat exchanger, mass flowrate and type of working fluids on the performance of downhole heat exchanger system. Consequently, work output of the best alternative is computed as 2511 kW(e) with 64 kg/s mass flowrate of R-134a for 2500 m-deep downhole heat exchanger having inner pipe diameter of 0.127 m. Electricity generation cost and simple payback time are calculated as 46 $/MWh and 2.25 years, respectively. The obtained results showed that the downhole heat exchanger system can be a feasible alternative for wells with very low geothermal flowrate to generate power. (C) 2019 Elsevier Ltd. All rights reserved.Article Citation - WoS: 12Citation - Scopus: 13Assessment of Thermal Comfort Preferences in Mediterranean Climate a University Office Building Case(Vinca Inst Nuclear Sci, 2018) Turhan, Cihan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyThis study aims at evaluating the perceived thermal sensation of occupants with respect to thermal comfort standards, ASHRAE 55 and ISO 7730, for office buildings located in Mediterranean climate. A small office building in Izmir Institute of Technology Campus Area, Izmir, Turkey, was chosen as a case building and equipped with measurement devices to assess thermal comfort of occupants with respect to predicted mean vote and actual mean vote. Both objective and subjective measurements were conducted. The former included indoor and outdoor air temperature, mean radiant temperature, relative humidity and air velocity that were used for evaluating the thermal comfort of occupants. Oxygen concentration which can play an additional role in thermal comfort/discomfort, health and productivity of the office occupants, was also measured. Furthermore, occupants were subjected to a survey via a mobile application to obtain subjective measurements to calculate actual mean vote values. Based on objective and subjective measurements, the relationships among the parameters were derived by using simple regression analysis technique while a new combined mean vote correlation was also derived but this time by using multiple linear regression model. Neutral and comfort temperatures were obtained using indoor air temperature and actual mean vote values which were calculated from subjective measurements. The results showed that neutral temperature in the university office building was 20.9 degrees C whilst the comfort temperature range was between 19.4 and 22.4 degrees C for the heating season. By applying new comfort temperatures, energy consumption of the case building located in Mediterranean climate, can be reduced.Conference Object Citation - WoS: 1Citation - Scopus: 3Green Smart Cities: Living Healthily With Every Breath(Institute of Electrical and Electronics Engineers Inc., 2019) Turhan, Cihan; Turhan, Cihan; Atalay, Ali Serdar; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyFifty-four percent of the world's population lives in big cities and it is projected to increase to nearly 70% by 2050s. Rapid and dense urbanization leads to smart cities which improve the quality of lives of the citizens. Therefore, development of smart cities is becoming vital. The quality of the citizens is affected by many factors including poor air quality, increased pollutants and microclimates called urban heat islands. The URBAN GreenUP project, initiated in June 2017, is a project funded under the European Union's Horizon 2020 programme. The main objective of the project is the development, application and replication of re-naturing Urban Plans in a number of European cities. In this study, measurement of nature-based solutions for mitigation of urban heat island effect and improvement of air quality for Urban GreenUP project in Izmir, will be introduced.Article Citation - WoS: 6Citation - Scopus: 9Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone(Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Durmuş Arsan, Zeynep; Turhan, Cihan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMost historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.Article Citation - WoS: 15Citation - Scopus: 11The Relation Between Thermal Comfort and Human-Body Exergy Consumption in a Temperate Climate Zone(Elsevier, 2019) Turhan, Cihan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyHuman body exergy balance calculation method gives minimum human body exergy consumption rates at thermal neutrality (TSV = 0) providing more information on human thermal responses than other methods. The literature is lacking the verification of this method in various climatic zones. The aim of this study is to investigate the relationship between thermal comfort and human body exergy consumption in a temperate climate zone. A small office building in Izmir Institute of Technology campus, Izmir/Turkey, was chosen as a case building and equipped with measurement devices. The occupant was subjected to a survey via a mobile application to obtain his Thermal Sensation Votes. Objective data were collected via sensors and used for predicting occupant thermal comfort and for exergy balance calculations. Under given conditions, the results show that Thermal Sensation Votes are generally zero at a T-i range of 21-23 degrees C and, are mostly lower than Predicted Mean Votes in summer while the opposite is observed in winter. Predicted Mean Votes at minimum Human Body Exergy Consumption rates were on slightly warm side while Thermal Sensation Votes are zero. It means that for given case, the HBexC rate calculation gave a better prediction of the environmental parameters for the best thermal comfort. (C) 2019 Elsevier B.V. All rights reserved.Conference Object Molecular Dynamics Study of the Thermal Conductivity of Graphene Coated Copper(Avestia Publishing, 2019) Toprak, Kasım; Toprak, Kasım; Ersavaş, Gizem; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyIn this study, the thermal conductivity of various size of pure copper, pure graphene and, different number of layer graphene coated copper models are studied using non-equilibrium molecular dynamics (NEMD) simulations. Our findings show that the thermal conductivity of graphene coated copper is higher than the uncoated ones. Furthermore, results also indicate that single layer graphene (SLG) model has the highest thermal conductivity as compared to the other model. Even though multiple layer graphene (MLG) has lower thermal conductivity value compare to SLG, this study shows that the thermal conductivity of MLG coated copper has higher thermal conductivity than SLG coated one. The most important finding in this study suggests that the thermal conductivity of copper can be improved using high thermal conductivity materials like graphene. © 2019, Avestia Publishing.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Coşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Durmuş Arsan, Zeynep; Şahin, Cem Doğan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Durmuş Arsan, Zeynep; Turhan, Cihan; Durmuş Arsan, Zeynep; Coşkun, Turgay; Turhan, Cihan; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Article Citation - WoS: 29Citation - Scopus: 39Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Şahin, Cem Doğan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Coşkun, Turgay; Durmuş Arsan, Zeynep; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.Article Citation - WoS: 6Citation - Scopus: 9Performance Analysis of Data-Driven and Model-Based Control Strategies Applied To a Thermal Unit Model(MDPI Multidisciplinary Digital Publishing Institute, 2017) Turhan, Cihan; Simani, Silvio; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyThe paper presents the design and the implementation of different advanced control strategies that are applied to a nonlinearmodel of a thermal unit. A data-driven grey-box identification approach provided the physically-meaningful nonlinear continuous-time model, which represents the benchmark exploited in this work. The control problem of this thermal unit is important, since it constitutes the key element of passive air conditioning systems. The advanced control schemes analysed in this paper are used to regulate the outflow air temperature of the thermal unit by exploiting the inflow air speed, whilst the inflow air temperature is considered as an external disturbance. The reliability and robustness issues of the suggested control methodologies are verified with a Monte Carlo (MC) analysis for simulating modelling uncertainty, disturbance and measurement errors. The achieved results serve to demonstrate the effectiveness and the viable application of the suggested control solutions to air conditioning systems. The benchmark model represents one of the key issues of this study, which is exploited for benchmarking different model-based and data-driven advanced control methodologies through extensive simulations. Moreover, this work highlights the main features of the proposed control schemes, while providing practitioners and heating, ventilating and air conditioning engineers with tools to design robust control strategies for air conditioning systems.
