    Assessment of Thermal Comfort Preferences in Mediterranean Climate a University Office Building Case
    (Vinca Inst Nuclear Sci, 2018) Turhan, Cihan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    This study aims at evaluating the perceived thermal sensation of occupants with respect to thermal comfort standards, ASHRAE 55 and ISO 7730, for office buildings located in Mediterranean climate. A small office building in Izmir Institute of Technology Campus Area, Izmir, Turkey, was chosen as a case building and equipped with measurement devices to assess thermal comfort of occupants with respect to predicted mean vote and actual mean vote. Both objective and subjective measurements were conducted. The former included indoor and outdoor air temperature, mean radiant temperature, relative humidity and air velocity that were used for evaluating the thermal comfort of occupants. Oxygen concentration which can play an additional role in thermal comfort/discomfort, health and productivity of the office occupants, was also measured. Furthermore, occupants were subjected to a survey via a mobile application to obtain subjective measurements to calculate actual mean vote values. Based on objective and subjective measurements, the relationships among the parameters were derived by using simple regression analysis technique while a new combined mean vote correlation was also derived but this time by using multiple linear regression model. Neutral and comfort temperatures were obtained using indoor air temperature and actual mean vote values which were calculated from subjective measurements. The results showed that neutral temperature in the university office building was 20.9 degrees C whilst the comfort temperature range was between 19.4 and 22.4 degrees C for the heating season. By applying new comfort temperatures, energy consumption of the case building located in Mediterranean climate, can be reduced.
  • Conference Object
    Citation - WoS: 1
    Citation - Scopus: 3
    Green Smart Cities: Living Healthily With Every Breath
    (Institute of Electrical and Electronics Engineers Inc., 2019) Turhan, Cihan; Turhan, Cihan; Atalay, Ali Serdar; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Fifty-four percent of the world's population lives in big cities and it is projected to increase to nearly 70% by 2050s. Rapid and dense urbanization leads to smart cities which improve the quality of lives of the citizens. Therefore, development of smart cities is becoming vital. The quality of the citizens is affected by many factors including poor air quality, increased pollutants and microclimates called urban heat islands. The URBAN GreenUP project, initiated in June 2017, is a project funded under the European Union's Horizon 2020 programme. The main objective of the project is the development, application and replication of re-naturing Urban Plans in a number of European cities. In this study, measurement of nature-based solutions for mitigation of urban heat island effect and improvement of air quality for Urban GreenUP project in Izmir, will be introduced.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 11
    The Relation Between Thermal Comfort and Human-Body Exergy Consumption in a Temperate Climate Zone
    (Elsevier, 2019) Turhan, Cihan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Human body exergy balance calculation method gives minimum human body exergy consumption rates at thermal neutrality (TSV = 0) providing more information on human thermal responses than other methods. The literature is lacking the verification of this method in various climatic zones. The aim of this study is to investigate the relationship between thermal comfort and human body exergy consumption in a temperate climate zone. A small office building in Izmir Institute of Technology campus, Izmir/Turkey, was chosen as a case building and equipped with measurement devices. The occupant was subjected to a survey via a mobile application to obtain his Thermal Sensation Votes. Objective data were collected via sensors and used for predicting occupant thermal comfort and for exergy balance calculations. Under given conditions, the results show that Thermal Sensation Votes are generally zero at a T-i range of 21-23 degrees C and, are mostly lower than Predicted Mean Votes in summer while the opposite is observed in winter. Predicted Mean Votes at minimum Human Body Exergy Consumption rates were on slightly warm side while Thermal Sensation Votes are zero. It means that for given case, the HBexC rate calculation gave a better prediction of the environmental parameters for the best thermal comfort. (C) 2019 Elsevier B.V. All rights reserved.
  • Conference Object
    Citation - WoS: 6
    Citation - Scopus: 8
    The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)
    (Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Coşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Durmuş Arsan, Zeynep; Şahin, Cem Doğan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture
    The indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 7
    The Importance of Internal Heat Gains for Building Cooling Design
    (Yıldız Teknik Üniversitesi, 2017) Durmuş Arsan, Zeynep; Turhan, Cihan; Durmuş Arsan, Zeynep; Coşkun, Turgay; Turhan, Cihan; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    This paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.
  • Article
    Citation - WoS: 12
    Citation - Scopus: 19
    Effect of Non-Condensable Gases on Geothermal Power Plant Performance. Case Study: Kızıldere Geothermal Power Plant-Turkey
    (Inderscience Enterprises Ltd., 2008) Gökçen Akkurt, Gülden; Yıldırım, Nurdan; Yıldırım, Nurdan; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Non-Condensable Gases (NCGs) are natural components of geothermal fluids, and they are a source of considerable capital and operating costs for power plants. The NCG content of geothermal steam varies over the world from almost zero to as much as 25% (wt). In this work, the influence of NCGs on the thermodynamic performance of geothermal power plants is analysed for various NCG content and turbine inlet temperatures. The results obtained can be useful on the feasibility study of single flash geothermal power plants. Depending on the NCG content of the field, the performance of the power plant can be determined roughly. © 2008, Inderscience Publishers.
  • Article
    Citation - WoS: 29
    Citation - Scopus: 39
    Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey
    (Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Şahin, Cem Doğan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Coşkun, Turgay; Durmuş Arsan, Zeynep; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture
    Conservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.
  • Conference Object
    Citation - WoS: 1
    Citation - Scopus: 2
    Analysis and Application of Advanced Control Strategies To a Heating Element Nonlinear Model
    (IOP Publishing Ltd., 2017) Turhan, Cihan; Turhan, Cihan; Zajic, Ivan; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    This paper presents the design of different control strategies applied to a heating element nonlinear model. The description of this heating element was obtained exploiting a data-driven and physically meaningful nonlinear continuous-time model, which represents a test-bed used in passive air conditioning for sustainable housing applications. This model has low complexity while achieving high simulation performance. The physical meaningfulness of the model provides an enhanced insight into the performance and functionality of the system. In return, this information can be used during the system simulation and improved model- based and data-driven control designs for tight temperature regulation. The main purpose of this study is thus to give several examples of viable and practical designs of control schemes with application to this heating element model. Moreover, extensive simulations and Monte- Carlo analysis are the tools for assessing experimentally the main features of the proposed control schemes, in the presence of modelling and measurement errors. These developed control methods are also compared in order to evaluate advantages and drawbacks of the considered solutions. Finally, the exploited simulation tools can serve to highlight the potential application of the proposed control strategies to real air conditioning systems.
  • Article
    Citation - WoS: 6
    Citation - Scopus: 9
    Performance Analysis of Data-Driven and Model-Based Control Strategies Applied To a Thermal Unit Model
    (MDPI Multidisciplinary Digital Publishing Institute, 2017) Turhan, Cihan; Simani, Silvio; Gökçen Akkurt, Gülden; Turhan, Cihan; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    The paper presents the design and the implementation of different advanced control strategies that are applied to a nonlinearmodel of a thermal unit. A data-driven grey-box identification approach provided the physically-meaningful nonlinear continuous-time model, which represents the benchmark exploited in this work. The control problem of this thermal unit is important, since it constitutes the key element of passive air conditioning systems. The advanced control schemes analysed in this paper are used to regulate the outflow air temperature of the thermal unit by exploiting the inflow air speed, whilst the inflow air temperature is considered as an external disturbance. The reliability and robustness issues of the suggested control methodologies are verified with a Monte Carlo (MC) analysis for simulating modelling uncertainty, disturbance and measurement errors. The achieved results serve to demonstrate the effectiveness and the viable application of the suggested control solutions to air conditioning systems. The benchmark model represents one of the key issues of this study, which is exploited for benchmarking different model-based and data-driven advanced control methodologies through extensive simulations. Moreover, this work highlights the main features of the proposed control schemes, while providing practitioners and heating, ventilating and air conditioning engineers with tools to design robust control strategies for air conditioning systems.
  • Article
    Citation - WoS: 96
    Citation - Scopus: 105
    Comparative Study of a Building Energy Performance Software (kep-Iyte and Ann-Based Building Heat Load Estimation
    (Elsevier Ltd., 2014) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Kazanasmaz, Zehra Tuğçe; Turhan, Cihan; Erlalelitepe Uygun, İlknur; Gökçen Akkurt, Gülden; Ekmen, Kenan Evren; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    The several parameters affect the heat load of a building; geometry, construction, layout, climate and the users. These parameters are complex and interrelated. Comprehensive models are needed to understand relationships among the parameters that can handle non-linearities. The aim of this study is to predict heat load of existing buildings benefiting from width/length ratio, wall overall heat transfer coefficient, area/volume ratio, total external surface area, total window area/total external surface area ratio by using artificial neural networks and compare the results with a building energy simulation tool called KEP-IYTE-ESS developed by Izmir Institute of Technology. A back propagation neural network algorithm has been preferred and both simulation tools were applied to 148 residential buildings selected from 3 municipalities of Izmir-Turkey. Under the given conditions, a good coherence was observed between artificial neural network and building energy simulation tool results with a mean absolute percentage error of 5.06% and successful prediction rate of 0.977. The advantages of ANN model over the energy simulation software are observed as the simplicity, the speed of calculation and learning from the limited data sets.