Mechanical Engineering / Makina Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4129

Browse

Search Results

Now showing 1 - 7 of 7
  • Article
    Citation - WoS: 13
    Citation - Scopus: 18
    Finite Element Study of Peek Materials Applied in Post-Retained Restorations
    (MDPI, 2022) Yu, Hao; Feng, Zhihong; Wang, Ling; Mihçin, Şenay; Kang, Jianfeng; Bai, Shizhu; Zhao, Yimin
    Background: This study aimed to investigate the biomechanical behaviors of polyether ether ketone (PEEK) and traditional materials (titanium and fiber) when used to restore tooth defects in the form of prefabricated post or customized post via computational modelling. Methods: First, the prototype of natural tooth, and the prototypes of prefabricated post and customized post were established, respectively, whilst the residual root was restored with dentin ferrule using reverse engineering methods. Then, the stress and strain of CFR-PEEK (PEEK reinforced by 30% carbon fiber) and pure PEEK (PEEK without any reprocessing) post were compared with those made in traditional materials using the three-dimensional finite element method. Results: From the stress point of view, compared with metal and fiber posts, CFR-PEEK and pure PEEK prefabricated post both demonstrated reduced post-core interface stress, post stress, post-root cement stress and root cement stress; moreover, CFR-PEEK and pure PEEK customized post demonstrated reduced post stress, post-root cement stress and root cement stress, while the strain of CFR-PEEK post was the closest to that of dentin. Conclusions: Compared with the traditional posts, both the CFR-PEEK and pure PEEK posts could reduce the risk of debonding and vertical root fracture, whether they were used as prefabricated posts or customized posts, but the biomechanical behavior of carbon fiber-reinforced CFR-PEEK restorations was the closest to dentin, no matter if they were used as prefabricated post or customized post. Therefore, the CFR-PEEK post could be more suitable to restore massive tooth defects. Pure PEEK needs filler reinforcement to be used for post-retained restoration.
  • Article
    Citation - WoS: 21
    Citation - Scopus: 22
    Daily Application of Low Magnitude Mechanical Stimulus Inhibits the Growth of Mda-Mb Breast Cancer Cells in Vitro
    (BioMed Central Ltd., 2014) Ölçüm, Melis; Özçivici, Engin
    Introduction: Mechanical loads can regulate cell proliferation and differentiation at various stages of development and homeostasis. However, the extension of this regulatory effect of mechanical loads on cancer cells is largely unknown. Increased physical compliance is one of the key features of cancer cells, which may hamper the transmission of mechanical loads to these cells within tumor microenvironment. Here we tested whether brief daily application of an external low magnitude mechanical stimulus (LMMS), would impede the growth of MDA-MB-231 aggressive type breast cancer cells in vitro for 3 wks of growth. Methods: The signal was applied in oscillatory form at 90 Hz and 0.15 g, a regimen that would induce mechanical loads on MDA-MB-231 cells via inertial properties of cells rather than matrix deformations. Experimental cells were exposed to LMMS 15 min/day, 5 days/week in ambient conditions while control cells were sham loaded. Cell proliferation, viability, cycle, apoptosis, morphology and migration were tested via Trypan Blue dye exclusion, MTT, PI, Annexin V, Calcein-AM and phalloidin stains and scratch wound assays. Results: Compared to sham controls, daily application of LMMS reduced the number and viability of cancerous MDA-MB-231 cells significantly after first week in the culture, while non-cancerous MCF10A cells were found to be unaffected. Flow cytomety analyses suggested that the observed decrease for the cancer cells in the LMMS group was due to a cell cycle arrest rather than apoptosis. LMMS further reduced cancer cell circularity and increased cytoskeletal actin in MDA-MB-231 cells. Conclusion: Combined, results suggest that direct application of mechanical loads negatively regulate the proliferation of aggressive type cancer cells. If confirmed, this non-invasive approach may be integrated to the efforts for the prevention and/or treatment of cancer.
  • Article
    Citation - WoS: 22
    Citation - Scopus: 24
    Size Dependent Influence of Contact Line Pinning on Wetting of Nano-textured/Patterned Silica Surfaces
    (Royal Society of Chemistry, 2020) Özçelik, H. Gökberk; Satıroğlu, Ezgi; Barışık, Murat
    Wetting behavior on a heterogeneous surface undergoes contact angle hysteresis as the droplet stabilized at a metastable state with a contact angle significantly different from its equilibrium value due to contact line pinning. However, there is a lack of consensus on how to calculate the influence of pinning forces. In general, the pinning effect can be characterized as (i) microscopic behavior when a droplet is pinned and the contact angle increases/decreases as the droplet volume increases/decreases and (ii) macroscopic behavior as the pinning effects decrease and ultimately, disappear with the increase of the droplet size. The current work studied both behaviors using molecular dynamics (MD) simulation with more than 300 different size water droplets on silica surfaces with three different patterns across two different wetting conditions. Results showed that the contact angle increases linearly with increasing droplet volume through the microscopic behavior, while the droplet is pinned on top of a certain number of patterns. When we normalized the droplet size with the corresponding pattern size, we observed a "wetting similarity" that linear microscopic contact angle variations over different size heterogeneities continuously line up. This shows that the pinning force remains constant and the resulting pinning effects are scalable by the size ratio between the droplet and pattern, independent of the size-scale. The slope of these microscopic linear variations decreases with an increase in the droplet size as observed through the macroscopic behavior. We further found a universal behavior in the variation of the corresponding pinning forces, independent of the wetting condition. In macroscopic behavior, pinning effects become negligible and the contact angle reaches the equilibrium value of the corresponding surface when the diameter of the free-standing droplet is approximately equal to 24 times the size of the surface structure. We found that the pinning effect is scalable with the droplet volume, not the size of the droplet base.
  • Article
    Citation - WoS: 26
    Citation - Scopus: 27
    Internal Surface Electric Charge Characterization of Mesoporous Silica
    (Nature Publishing Group, 2019) Şen, Tümcan; Barışık, Murat
    Mesoporous silica is an emerging technology to solve problems of existing and to support projected revolutionary applications ranging from targeted drug delivery to artificial kidney. However, one of the major driving mechanisms, electric charging of internal mesoporous surfaces, has not been characterized yet. In the nanoscale confinements of mesoporous structures made of pore throats and pore voids, surface charges diverge from existing theoretical calculations and show local variation due to two occurrences. First, when the size of pore throat becomes comparable with the thickness of ionic layering forming on throats' surfaces, ionic layers from opposite surfaces overlap so that ionic concentration on the surface becomes different than Boltzmann distribution predicts, and there will no longer be an equilibrium of zero electric potential at pore throat centers. Second, when this non zero potential inside throats becomes different than the potential of pore voids, ionic diffusion from void to throat creates axial ionic variation on surfaces. For such a case, we performed a pore level analysis on mesoporous internal surface charge at various porosities and ionic conditions. Pore parameters strongly affected the average internal charge which we characterized as a function of overlap ratio and porosity, first time in literature. Using this, a phenomenological model was developed as an extension of the existing theory to include nano-effects, to predict the average mesoporous internal surface charge as a function of EDL thickness, pore size and porosity.
  • Article
    Citation - WoS: 57
    Citation - Scopus: 61
    Viewpoints: Feeding Mechanics, Diet, and Dietary Adaptations in Early Hominins
    (John Wiley and Sons Inc., 2013) Daegling, David J.; Judex, Stefan; Özçivici, Engin; Ravosa, Matthew J.; Taylor, Andrea B.; Grine, Frederick E.; Teaford, Mark F.; Ungar, Peter S.
    Inference of feeding adaptation in extinct species is challenging, and reconstructions of the paleobiology of our ancestors have utilized an array of analytical approaches. Comparative anatomy and finite element analysis assist in bracketing the range of capabilities in taxa, while microwear and isotopic analyses give glimpses of individual behavior in the past. These myriad approaches have limitations, but each contributes incrementally toward the recognition of adaptation in the hominin fossil record. Microwear and stable isotope analysis together suggest that australopiths are not united by a single, increasingly specialized dietary adaptation. Their traditional (i.e., morphological) characterization as "nutcrackers" may only apply to a single taxon, Paranthropus robustus. These inferences can be rejected if interpretation of microwear and isotopic data can be shown to be misguided or altogether erroneous. Alternatively, if these sources of inference are valid, it merely indicates that there are phylogenetic and developmental constraints on morphology. Inherently, finite element analysis is limited in its ability to identify adaptation in paleobiological contexts. Its application to the hominin fossil record to date demonstrates only that under similar loading conditions, the form of the stress field in the australopith facial skeleton differs from that in living primates. This observation, by itself, does not reveal feeding adaptation. Ontogenetic studies indicate that functional and evolutionary adaptation need not be conceptually isolated phenomena. Such a perspective helps to inject consideration of mechanobiological principles of bone formation into paleontological inferences. Finite element analysis must employ such principles to become an effective research tool in this context. © 2013 Wiley Periodicals, Inc.
  • Article
    Citation - WoS: 18
    Citation - Scopus: 21
    Genetic Loci That Control the Loss and Regain of Trabecular Bone During Unloading and Reambulation
    (John Wiley and Sons Inc., 2013) Judex, Stefan; Zhang, Weidong; Donahue, Leah Rae; Özçivici, Engin
    Changes in trabecular morphology during unloading and reloading are marked by large variations between individuals, implying that there is a strong genetic influence on the magnitude of the response. Here, we subjected more than 350 second-generation (BALBxC3H) 4-month-old adult female mice to 3 weeks of hindlimb unloading followed by 3 weeks of reambulation to identify the quantitative trait loci (QTLs) that define an individual's propensity to either lose trabecular bone when weight bearing is removed or to gain trabecular bone when weight bearing is reintroduced. Longitudinal in vivo micro-computed tomography (μCT) scans demonstrated that individual mice lost between 15% and 71% in trabecular bone volume fraction (BV/TV) in the distal femur during unloading (average: -43%). Changes in trabecular BV/TV during the 3-week reambulation period ranged from a continuation of bone loss (-18%) to large additions (56%) of tissue (average: +10%). During unloading, six QTLs accounted for 21% of the total variability in changes in BV/TV whereas one QTL accounted for 6% of the variability in changes in BV/TV during reambulation. QTLs were also identified for changes in trabecular architecture. Most of the QTLs defining morphologic changes during unloading or reambulation did not overlap with those QTLs identified at baseline, suggesting that these QTLs harbor genes that are specific for sensing changes in the levels of weight bearing. The lack of overlap in QTLs between unloading and reambulation also emphasizes that the genes modulating the trabecular response to unloading are distinct from those regulating tissue recovery during reloading. The identified QTLs contain the regulatory genes underlying the strong genetic regulation of trabecular bone's sensitivity to weight bearing and may help to identify individuals that are most susceptible to unloading-induced bone loss and/or the least capable of recovering.
  • Article
    Citation - WoS: 22
    Citation - Scopus: 28
    Mechanical Interlocking Between Porous Electrospun Polystyrene Fibers and an Epoxy Matrix
    (American Chemical Society, 2014) Demir, Mustafa Muammer; Horzum, Nesrin; Taşdemirci, Alper; Turan, Ali Kıvanç; Güden, Mustafa
    An epoxy matrix filled with nonwoven mats of porous polystyrene (PS) fibers processed by an electrospinning was compression tested at quasi-static (1 × 10–3 s–1) and high strain (315 s–1) rates. The electrospun PS fibers with a diameter between 6 and 9 μm, accommodated spherical pores on the surface with the sizes ranging from 0.1 to 0.2 μm. The filling epoxy matrix with 0.2 wt % PS fibers increased the compressive elastic modulus and compressive strength over those of neat epoxy resin. The microscopic observations indicated that the surface pores facilitated the resin intrusions into the fiber, enhancing the interlocking between resin and fibers, and increased the deformation energy expenditure of the polymer matrix.