Mechanical Engineering / Makina Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4129

Browse

Search Results

Now showing 1 - 4 of 4
  • Article
    Citation - WoS: 9
    Citation - Scopus: 13
    Analysis of Adhesively Bonded Joints of Laser Surface Treated Composite Primary Components of Aircraft Structures
    (Elsevier, 2023) Martin, Seçkin; Nuhoğlu, Kaan; Aktaş, Engin; Tanoğlu, Metin; İplikçi, Hande; Barışık, Murat; Yeke, Melisa; Türkdoğan, Ceren; Esenoğlu, Gözde; Dehneliler, Serkan
    The performance of the adhesively bonded aerospace structures highly depends on the adhesion strength between the adhesive and adherents, which is affected by, in particular, the condition of the bonding surface. Among the various surface treatment methods, as state of the art, laser surface treatment is a suitable option for the CFRP composite structures to enhance the adhesion performance, adjusting the roughness and surface free energy with relatively minimizing the damage to the fibers. The aim of this study is the validation and evaluation of the adhesive bonding behavior of the laser surface-treated CFRP composite structures, using the finite element technique to perform a conservative prediction of the failure load and damage growth. Such objectives were achieved by executing both experimental and numerical analyses of the secondary bonded CFRP parts using a structural adhesive. In this regard, to complement physical experiments by means of numerical simulation, macro-scale 3D FEA of adhesively bonded Single Lap Joint and Skin-Spar Joint specimens has been developed employing the Cohesive Zone Model (CZM) technique in order to simulate bonding behavior in composite structures especially skin-spar relation in the aircraft wing-box.
  • Article
    Citation - WoS: 3
    Citation - Scopus: 3
    Quasi-Static and Dynamic Brazilian Testing and Failure Analysis of a Deer Antler in the Transverse To the Osteon Growth Direction
    (Elsevier, 2023) Orhan, Mehmet; Sarıkaya, Mustafa Kemal; Taşdemirci, Alper; Tuncer, Can; Güden, Mustafa
    The transverse tensile strength of a naturally fallen red deer antler (Cervus Elaphus) was determined through indirect Brazilian tests using dry disc-shape specimens at quasi-static and high strain rates. Dynamic Brazilian tests were performed in a compression Split-Hopkinson Pressure Bar. Quasi-static tensile and indirect Brazilian tests were also performed along the osteon growth direction for comparison. The quasi-static transverse tensile strength ranged 31.5–44.5 MPa. The strength increased to 83 MPa on the average in the dynamic Brazilian tests, proving a rate sensitive transverse strength. The quasi-static tensile strength in the osteon growth direction was however found comparably higher, 192 MPa. A Weibull analysis indicated a higher tensile ductility in the osteon growth direction than in the transverse to the osteon growth direction. The microscopic analysis of the quasi-static Brazilian test specimens (tensile strain along the osteon growth direction) revealed a micro-cracking mechanism operating by the crack deflection/twisting at the lacunae in the concentric lamellae region and at the interface between concentric lamellae and interstitial lamellae. On the other side, the specimens in the transverse direction fractured in a more brittle manner by the separation/delamination of the concentric lamellae and pulling of the interstitial lamellae. The detected increase in the transverse strength in the high strain rate tests was further ascribed to the pull and fracture of the visco-plastic collagen fibers in the interstitial lamellae. This was also confirmed microscopically; the dynamically tested specimens exhibited flatter fracture surfaces. © 2023 Elsevier Ltd
  • Article
    Citation - WoS: 5
    Citation - Scopus: 8
    Detailed Investigation of Three-Dimensional Modeling and Printing Technologies From Medical Images To Analyze Femoral Head Fractures Using Finite Element Analysis
    (Elsevier, 2022) Çıklacandır, Samet; Mihçin, Şenay; İşler, Yalçın
    Objectives: One of the fields, where additive manufacturing has numerous applications, is biomedical engineering. 3D printing is preferred over traditional manufacturing methodologies, mostly while developing subject-specific implants and medical devices. This study aims to provide a process flow detailing all the stages starting from the acquisition of radiological images from different imaging modalities; such as computed tomography (CT) and magnetic resonance imaging (MRI) to the printing of the bone morphology and finite element analysis; including the validation process. Materials & Methods: First, the CT scan of a lower abdomen area of a patient was converted into a 3D image using interactive medical imaging control system software. The segmentation process was applied to isolate the femoral head from the soft tissue and the pelvic bone. After the roughness errors and the gaps in the segments were removed using the 3Matic software, the file was converted to stereolithography (STL) file format to transfer to the 3D printer. The printing process was carried out via commercial powder-based Selective Laser Sintering (SLS) printer. The subject-specific femoral head model was formed in 3D. The Finite Element Analysis (FEA) of the femoral head was performed using a commercial FE software package. Results: The results show that experimental analysis and the CT scan-based FEA were compatible both for the stress distributions and the strain values as predicted by the models (R2=0.99). The deviation was calculated as approximately 12% between the experimental results and the Finite Element (FE) results. In addition, it was observed that the SLS technique produced useful results for modeling biomedical tissues with about 24x faster prototyping time. Conclusion: The prescribed process flow could be utilized in clinical settings for the pre-planning of the surgeries (≈428 minutes for femoral head) and also as an educational tool in the biomedical engineering field.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 8
    Size and Roughness Dependent Temperature Effects on Surface Charge of Silica Nanoparticles
    (Elsevier, 2021) Alan, Büşra Öykü; Barışık, Murat
    Silica nanoparticles (SNP) with different sizes and surface areas are used in numerous micro/nanofluidic applications, while their surface charge properties play a major role in their function. In many of these applications, SNPs also undergo temperature variation. We present that an increase in temperature yields a substantial increase in SNP surface charge depending on nanoparticle size and surface roughness, which cannot be estimated by existing theory. As a continuation of our earlier work characterizing the deviation of SNP surface charging from theoretical predictions due to curvature and EDL overlap effects, this study presents the differentiation from the theory in temperature dependence under various conditions. As we calculate surface chemistry as a function of local ionic conditions (Charge Regulation), temperature variation changed the equilibrium constants of protonation/deprotonation reactions of the SNP surface, in addition to changes occurring in relative permittivity and ionic mobilities. Results show that variation of SNP surface charge by temperature decreases by decreasing particle size and/or increasing roughness size, compare to theoretical flat plate calculations considering similar temperature-dependent properties and charge regulation on the surface. We characterized these deviations by obtaining an electrokinetic similarity between different systems of various size and roughness at various ionic conditions based on the non-dimensional groups of lambda/DP and lambda/DR. Based on these, we devised a phenomenological model as an extension to the flat plate theory to successfully predict the surface charge of SNPs as a function of the particle size, roughness size, and temperature. The current findings are important for the characterization of SNPs through temperature variations and can also be used to adjust the surface charge of SNPs by tuning the temperature.