Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
4 results
Search Results
Article AI-Supported Seismic Performance Evaluation of Structures: Challenges, Gaps, and Future Directions at Early Design Stages(Elsevier Sci Ltd, 2026) Ak, Fatma; Ekici, Berk; Demir, UgurThis study reviews 91 journal articles that intersect with earthquake-resistant building design and artificial intelligence (AI)- based modeling, utilizing machine learning, deep learning, and metaheuristic optimization algorithms. Previous reviews on AI applications have examined engineering problems without considering the impact of architectural design parameters and structural irregularities on seismic performance. This review discusses the role of AI in integrating architectural design variables and seismic performance objectives, highlighting challenges, gaps, and future directions in the early design phase. The reviewed articles demonstrate that AI is successful in addressing seismic performance objectives; however, a holistic framework for assessing architectural and structural variables has not been presented. The review highlights key findings, gaps, and future directions for those involved in earthquake-resistant building design utilizing AI.Article Damage Assessment of Structures Following the February 6, 2023 Kahramanmaraş Earthquakes: A Dataset-Based Case Study in Gaziantep, Türkiye(Springer Heidelberg, 2025) Atasever, Kurtulus; Aydogdu, Hasan Huseyin; Narlitepe, Furkan; Goksu, Caglar; Demir, Ugur; Demir, Cem; Ilki, AlperFollowing the 2023 Kahramanmara & scedil; Earthquakes (Mw 7.7 and 7.6) that struck T & uuml;rkiye on February 6, 2023, the Ministry of Environment, Urbanization, and Climate Change (MoEUCC) initiated a large-scale post-earthquake damage assessment campaign, targeting more than 2,3 million structures within the affected region. A comprehensive field survey was carried out in and around Gaziantep, one of the most severely affected cities. The authors assessed more than 1700 structures representing a wide range of occupancy types, including residential, educational, healthcare, religious, administrative, industrial, and lodging structures. In this paper, the methodological process of post-earthquake data collection in and around Gaziantep is presented, together with the data on the distribution of damage with respect to construction period, number of stories, and building occupancy type, to ensure a complete understanding of the extent and characteristics of structural damage. The damage assessment employed two data sources: (i) the data gathered through the authors' newly developed, novel damage-assessment software, presented here for the first time, and (ii) the official post-earthquake damage database of the MoEUCC. A further novelty of this study is the presentation of the largest dataset to date for the investigated earthquake doublet, encompassing approximately 1700 buildings. Additionally, the relationship between damage states, peak ground accelerations, and fault distances is thoroughly investigated. The detailed earthquake-hit site investigations revealed that the examined structures displayed structural inadequacies akin to those witnessed in previous seismic events, with a notable focus on the arrangement of the structural system, the quality of construction materials and reinforcement detailing.Article Repair and Strengthening of Fire Damaged Concrete Cylinders Using FRP Confinement: Tests and Analytical Modelling(Elsevier Science inc, 2025) Demir, Ugur; Ilki, AlperThis study examines the effects of fiber-reinforced polymer (FRP) repair and strengthening on the axial stress-strain behavior of concrete columns after exposure to realistic fires. A total of 30 plain concrete cylinders, each measuring 150 x 300 mm, were cast for this investigation. Of these, three specimens were kept as reference at ambient temperature, while the remaining were exposed to ISO-834 standard fire for durations of 30, 60 or 90 min, with nine specimens in each duration group. After natural cooling, the heated specimens were categorized into three groups: i) three were left unconfined, ii) three were repaired and strengthened using two layers of carbon FRP sheets, and iii) three were repaired and strengthened with four layers of carbon FRP sheets. This study employs realistic ISO 834 fire scenarios and investigates CFRP confinement with up to four layers, addressing high confinement demands beyond current literature. The results showed that transverse confinement provided by carbon FRP sheets significantly improved axial strength and deformability for all specimens, while it did not fully restore the axial stiffness achieved before fire exposure. The effectiveness of FRP confinement increased with longer fire exposure durations. Additionally, two analytical models proposed previously for predicting the axial strength and ultimate strain of FRP confined fire-damaged concrete were evaluated in terms of their accuracy. The accuracy of the predictions was reduced with an increase in exposure temperatures for both models. Therefore, a new model is proposed within the scope of study, which shows good agreement with the novel test results.Article A Comprehensive Database and a New Model for the Axial Response of Heat-Damaged Concrete Before and After FRP Confinement(Springer, 2025) Akdag, Nefise; Demir, UgurIn this study, a total of 330 concrete specimens, compiled from existing experimental data, are systematically reviewed to assess their post-fire axial stress-strain behavior before and after circumferential confinement with fiber-reinforced polymers (FRPs). The selection criteria for the database are as follows: (i) studies had to be published in English, (ii) both lateral and axial ultimate strains must have been measured, (iii) the use of additional strengthening materials in combination with FRPs was excluded, (iv) only plain concrete specimens were considered, and (v) specimen dimensions and instrumentation details had to be explicitly reported. The dataset is structured to include heating/cooling and curing conditions, specimen properties, and FRP characteristics. Subsequently, the predictive accuracy of available models for post-fire axial strength and ultimate strain of concrete members, both before and after FRP confinement, is evaluated. The results based on the reviewed comprehensive database indicate that these models are inadequate in capturing the observed behavior in the experiments. As such, a new analytical model is developed based on the compiled dataset. The proposed model demonstrated reliable predictive performance in terms of post-fire axial response of concrete before and after FRP confinement while remaining user-friendly for practical engineering applications. This is done such that universal design guidelines on the behavior of heat-damaged concrete strengthened by FRP composites can be reliably formulated.
