    Database Covering the Prayer Movements Which Were Not Available Previously
    (Nature Publishing Group, 2023) Mihçin, Şenay; Şahin, Ahmet Mert; Alpkaya, Alican Tuncay; Alpkaya, Alican Tuncay; Tuna, Merve; Mihçin, Şenay; Can, Nuray Korkmaz; Tosun, Aliye; Şahin, Serap; 03.04. Department of Computer Engineering; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering
    Lower body implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. A database covering these diverse activities of the Eastern world is non-existent. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations with a special focus on the lower body joints. The current version of the database covers 50 volunteers for 13 different activities. The tasks are defined and listed in a table to create a database to search based on age, gender, BMI, type of activity, and motion capture system. The collected data is to be used for designing implants to allow these sorts of activities to be performed.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 10
    The Computational Approach To Predicting Wear: Comparison of Wear Performance of Cfr-Peek and Xlpe Liners in Total Hip Replacement
    (Taylor & Francis, 2022) Alpkaya, Alican Tuncay; Mihçin, Şenay; Alpkaya, Alican Tuncay; Mihçin, Şenay; 01. Izmir Institute of Technology; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering
    Wear on articulating bearing surfaces is a key factor causing revision in total hip replacement (THR). Wear debris that releases particles from bearing surfaces might result in adverse soft tissue reactions requiring revision surgeries. In this study, a comprehensive computational wear model based on the Archard wear equation was performed to investigate the wear performance under a three-dimensional (3D) physiological gait cycle, mimicking a normal walking condition (5 million cycles). The study shows that the accuracy of the model is highly dependent on the mesh convergence, the wear fraction, and the scaling factor. The simulations were run to provide a vast amount of detail for the reproducibility of the work. Cobalt chromium (CoCr) on cross-linked polyethylene (XLPE) and CoCr on carbon-fiber-reinforced polyether ether ketone (CFR-PEEK) prototype models were created in silico. The volumetric wear rates for CoCr-on-XLPE were calculated as 0.2989 (Formula presented.) for CoCr head and 21.0271 (Formula presented.) for XLPE liner, while for CoCr-on-CFR-PEEK they were 0.3484 (Formula presented.) for CoCr head and 1.8476 (Formula presented.) for CFR-PEEK liner. When compared to in vivo and in vitro studies, the wear patterns of these two prototypes are consistent with those of the conventional polyethylene liners in the literature. Although the volumetric wear rate of the CFR-PEEK liner is about 11 times lower than the counterpart of XLPE in MoP implants, the wear rate of CoCr was higher when compared to its use with XLPE. Therefore, CFR-PEEK articulating against orthopa\edic metals may not be as good an alternative as XLPE, due to higher indicative metallic wear. This detailed computational wear modeling methodology could be utilized in design improvements of implants.