Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - WoS: 29
    Citation - Scopus: 29
    Investigating Silicon Wafer Based Substrates for Dried-Droplet Analysis by Laser-Induced Breakdown Spectroscopy
    (Elsevier Ltd., 2019) Aras, Nadir; Yalçın, Şerife
    This work communicates a critical assessment on the analytical capability of the three silicon wafer-based substrates; crystalline silicon (c-Si), oxide-coated silicon (SiO2-Si), and nitride-coated silicon (Si3N4-Si), for dried-droplet analysis by laser-induced breakdown spectroscopy. The methodology consists of loading, drying and analyzing steps. First, nanoliter volume of droplets are manually loaded onto the substrate and dried at room temperature. Then, the dry residue is subjected to high peak power (1.15 GW/cm(2)) laser pulses focused outside the minimum focal point condition and luminescent plasma is spectroscopically analyzed. Results revealed that nitride-coated substrate exhibits strong enhancements in signal intensity for most emission lines of the analyte species investigated: Cd, Cr, Cu, Mn, and Pb. Surface reflectivity and surface morphology were comparatively investigated to explore enhanced analytical performance of nitride-coated substrates. Experimental conditions were optimized and growth curves for all the elements are found linear with minimum regression constant of 0.96. LOD's of 62 pg Cd, 1.5 pg Cr, 0.5 pg Cu, 2 pg Mn and 11 pg Pb, in absolute amounts, were obtained. The accuracy and precision of the methodology were tested on certified reference water sample (CRM-TMDW), and ICP-multi-element standard sample (ICP-MES). The surface enhancement effect observed on Si3N4 coated substrates has improved the analytical capability of laser-induced breakdown spectroscopy for liquid analysis.
  • Article
    Citation - WoS: 42
    Citation - Scopus: 44
    Development and Validation of a Laser-Induced Breakdown Spectroscopic Method for Ultra-Trace Determination of Cu, Mn, Cd and Pb Metals in Aqueous Droplets After Drying
    (Elsevier Ltd., 2016) Aras, Nadir; Yalçın, Şerife
    The present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300 nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3 pg Cu, 3.3 pg Mn, 79 pg Cd and 48 pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300 nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology.
  • Article
    Citation - WoS: 62
    Citation - Scopus: 64
    Ultrasonic Nebulization-Sample Introduction System for Quantitative Analysis of Liquid Samples by Laser-Induced Breakdown Spectroscopy
    (Elsevier Ltd., 2012) Aras, Nadir; Ünal Yeşiller, Semira; Ateş Arıca, Dilek; Yalçın, Şerife
    In this study, design and optimization studies of a sample introduction system based on ultrasonic nebulization of metal salts in aqueous environment for laser-induced breakdown spectroscopic detection were presented. The system consisted of an ultrasonic nebulizer connected to a tandem heater-condenser- membrane dryer unit that produces sub-micron size aerosols. Results indicate improvements in detection limits for some elements with the use of membrane dryer. Optimization studies were performed by systematical investigation of LIBS emission signal with respect to laser energy, carrier gas flow rate and detector timing parameters. Under optimized conditions, calibration graphs for Na, K, Mg, Ca, Cu, Al, Cr, Cd, Pb and Zn were constructed and detection limits were calculated. The applicability of the ultrasonic nebulization-LIBS system was tested on real water samples. This system establishes LIBS as an effective analytical tool for both qualitative and quantitative determination of metal aerosols in aqueous environments. This technique is sufficiently rapid to provide real-time monitoring of toxic metals.