Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 20
    Citation - Scopus: 24
    Preparation and Characterization of Sodium Dodecyl Sulfate Doped Polypyrrole Solid Phase Micro Extraction Fiber and Its Application To Endocrine Disruptor Pesticide Analysis
    (Elsevier Ltd., 2013) Korba, Korcan; Pelit, Levent; Okçu Pelit, Füsun; Özdokur, K. Volkan; Ertaş, Hasan; Eroğlu, Ahmet Emin; Ertaş, Fatma Nil
    A robust in house solid-phase micro extraction (SPME) surface has been developed for the headspace (HS)-SPME determination of endocrine disruptor pesticides, namely, Chlorpyrifos, Penconazole, Procymidone, Bromopropylate and Lambda-Cyhalothrin in wine sample by using sodium dodecylsulfate doped polypyrrole SPME fiber. Pyrrole monomer was electrochemically polymerized on a stainless steel wire in laboratory conditions in virtue of diminishing the cost and enhancing the analyte retention on its surface to exert better selectivity and hence the developed polymerized surface could offer to analyst to exploit it as a fiber in headspace SPME analysis. The parameters, mainly, adsorption temperature and time, desorption temperature, stirring rate and salt amount were optimized to be as 70°C and 45min, 200°C, 600rpm and 10gL-1, respectively. Limit of detection was estimated in the range of 0.073-1.659ngmL-1 for the pesticides studied. The developed method was applied in to red wine sample with acceptable recovery values (92-107%) which were obtained for these selected pesticides.
  • Article
    Citation - WoS: 16
    Citation - Scopus: 19
    Application of Experimental Design on Determination of Aluminum Content in Saline Samples by Adsorptive Cathodic Stripping Voltammetry
    (TUBITAK, 2013) Yılmaz, Sinan; Öztürk, Betül; Özdemir, Durmuş; Eroğlu, Ahmet Emin; Ertaş, Fatma Nil
    Adsorptive cathodic stripping voltammetric determination of aluminum at ng mL-1 levels in salt samples based on the metal complexation with Calcon (1-(2-hydroxynaphthylazo)-2 naphthol-4-sulfonic acid) and the subsequent adsorptive deposition onto a hanging mercury drop electrode was studied. Central composite design was used as a design method. Several chemical and instrumental parameters (pH, ligand concentration, deposition time, deposition potential, and complexing time) were involved in the experimental design. Analytical parameters such as repeatability, linearity, and accuracy were also investigated and the detection limit was found as 0.32 ng mL-1.