Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 10 of 11
  • Article
    Citation - WoS: 33
    Citation - Scopus: 41
    Development of a Personalized Thermal Comfort Driven Controller for Hvac Systems
    (Elsevier Ltd., 2021) Turhan, Cihan; Simani, Silvio; Turhan, Cihan; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Increasing thermal comfort and reducing energy consumption are two main objectives of advanced HVAC control systems. In this study, a thermal comfort driven control (PTC-DC) algorithm was developed to improve HVAC control systems with no need of retrofitting HVAC system components. A case building located in Izmir Institute of Technology Campus-Izmir-Turkey was selected to test the developed system. First, wireless sensors were installed to the building and a mobile application was developed to monitor/collect temperature, relative humidity and thermal comfort data of an occupant. Then, the PTC-DC algorithm was developed to meet the highest occupant thermal comfort as well as saving energy. The prototypes of the controller were tested on the case building from July 3rd, 2017 to November 1st, 2018 and compared with a conventional PID controller. The results showed that the developed control algorithm and conventional controller satisfy neutral thermal comfort for 92 % and 6 % of total measurement days, respectively. From energy consumption point of view, the PTC-DC decreased energy consumption by 13.2 % compared to the conventional controller. Consequently, the PTC-DC differs from other works in the literature that the prototype of PTC-DC can be easily deployed in real environments. Moreover, the PTC-DC is low-cost and user-friendly.
  • Conference Object
    Citation - WoS: 6
    Citation - Scopus: 8
    The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)
    (Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Coşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Durmuş Arsan, Zeynep; Şahin, Cem Doğan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture
    The indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.
  • Conference Object
    Citation - WoS: 21
    Citation - Scopus: 27
    Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey
    (Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Durmuş Arsan, Zeynep; 02.02. Department of Architecture; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    Mosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.
  • Article
    Citation - WoS: 29
    Citation - Scopus: 39
    Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey
    (Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Şahin, Cem Doğan; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Coşkun, Turgay; Durmuş Arsan, Zeynep; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture
    Conservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.
  • Article
    Citation - WoS: 74
    Citation - Scopus: 85
    A Transdisciplinary Approach on the Energy Efficient Retrofitting of a Historic Building in the Aegean Region of Turkey
    (Elsevier Ltd., 2015) Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Şahin, Cem Doğan; Tunçoku, Selim Sarp; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 02.01. Department of Conservation and Restoration of Cultural Heritage; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture
    Abstract Buildings account for 40% of total energy consumption in the European Union, yet at the same time they have considerable energy saving potentials. Historic buildings should be treated different from contemporary ones when it comes to energy improvements. The specifications which underline historical, sociocultural and architectural values require certain care during realization of energy saving implementations to sustain these values. The purpose of this study is to demonstrate how the energy efficient retrofitting in historic buildings should be managed in a transdisciplinary approach with a case study conducted on the historic building in ̄zmir - Turkey. A detailed building energy simulation tool was used to determine the impacts of energy efficient retrofits. The actual energy consumption of case building was based on the utility bills regarding electricity and heating fuel consumption. Building energy simulation tool was calibrated by comparing the measured and simulated indoor air temperatures and total energy consumptions. The inappropriate retrofits, which contradict to the cultural heritage values, were eliminated with a transdisciplinary approach. Later appropriate retrofits were gathered into three packages to evaluate their effects on the energy consumption. The results show that energy saving of more than 34% can be obtained without damaging the heritage values.
  • Article
    Citation - WoS: 96
    Citation - Scopus: 105
    Comparative Study of a Building Energy Performance Software (kep-Iyte and Ann-Based Building Heat Load Estimation
    (Elsevier Ltd., 2014) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Kazanasmaz, Zehra Tuğçe; Turhan, Cihan; Erlalelitepe Uygun, İlknur; Gökçen Akkurt, Gülden; Ekmen, Kenan Evren; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    The several parameters affect the heat load of a building; geometry, construction, layout, climate and the users. These parameters are complex and interrelated. Comprehensive models are needed to understand relationships among the parameters that can handle non-linearities. The aim of this study is to predict heat load of existing buildings benefiting from width/length ratio, wall overall heat transfer coefficient, area/volume ratio, total external surface area, total window area/total external surface area ratio by using artificial neural networks and compare the results with a building energy simulation tool called KEP-IYTE-ESS developed by Izmir Institute of Technology. A back propagation neural network algorithm has been preferred and both simulation tools were applied to 148 residential buildings selected from 3 municipalities of Izmir-Turkey. Under the given conditions, a good coherence was observed between artificial neural network and building energy simulation tool results with a mean absolute percentage error of 5.06% and successful prediction rate of 0.977. The advantages of ANN model over the energy simulation software are observed as the simplicity, the speed of calculation and learning from the limited data sets.
  • Article
    Citation - WoS: 23
    Citation - Scopus: 26
    On the Relation Between Architectural Considerations and Heating Energy Performance of Turkish Residential Buildings in Izmir
    (Elsevier Ltd., 2014) Kazanasmaz, Zehra Tuğçe; Erlalelitepe Uygun, İlknur; Turhan, Cihan; Turhan, Cihan; Ekmen, Kenan Evren; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    By considering the energy efficiency legislations among the European Union, Turkey is responsible to provide regulations to comply for the latest European Energy Performance of Buildings Directive 2010/31/EC. New legislation in Turkey requires information about the evaluation of energy performance of existing buildings. This study aimed to determine energy performance of residential buildings in Izmir, regarding significant relationships between their performance and architectural configuration through statistical analysis. The focus was on the heating energy consumption due to Energy Efficiency Law (2007) and Building Energy Performance Regulation (2008), and Standard Assessment Method for Energy Performance of Dwellings (KEP-SDM). This energy performance assessment method was based on Turkish standard TS 825, and European standard EN ISO 13790. It is known that architectural configuration of buildings and design norms have impact on energy performance of buildings. However, emphasis was given on significant values of architectural considerations through certain area-based ratios. The levels of these ratios were matched with the levels of energy consumption. By this, the consideration was to take early-precautions against high energy consumptions in the early design stage and to enhance legislation by adding recommendations of concrete architectural values. These would assist to predict the level of energy performance in the early design phase. Findings would provide feedback information on the residential building stock in İzmir, Turkey.
  • Article
    Citation - WoS: 22
    Citation - Scopus: 26
    Thermodynamic Assessment of Gas Removal Systems for Single-Flash Geothermal Power Plants
    (Elsevier Ltd., 2009) Yıldırım Özcan, Nurdan; Gökçen Akkurt, Gülden; Yıldırım, Nurdan; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Geothermal fluids contain non-condensable gases (NCGs) at various amounts. NCGs flow to a conventional geothermal power plant (GPP) with steam phase and should be withdrawn from the condenser by a gas removal system to prevent increase in condenser pressure and consequently decrease in power generation. Therefore, to remove NCGs from the system is critical especially at high NCG fractions. In this study, the net power output and specific steam consumption of a single-flash GPP is evaluated depending on the separator pressure, NCG fraction and wet bulb temperature of the environment, and three different conventional gas removal options which are two-stage steam jet ejector system, two-stage hybrid system and two-stage compressor system. A simulation code is written in EES to model the plant for each option. The model uses the data of Kizildere Geothermal Power Plant (KGPP) - Turkey, which is a single-flash plant with extremely high NCG fraction, to allow a comparison between the results of the modelling and the operational data of an actual single-flash GPP. Under given conditions, thermodynamic analysis resulted that NCG fraction is the most significant factor on GPP performance and the compressor system is the most efficient and robust option where the influence of the NCG fraction is limited.
  • Article
    Citation - WoS: 25
    Citation - Scopus: 32
    District Heating System Design for a University Campus
    (Elsevier Ltd., 2006) Yıldırım, Nurdan; Toksoy, Macit; Toksoy, Macit; Yıldırım, Nurdan; Gökçen Akkurt, Gülden; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    İzmir Institute of Technology campus is in use since 2000 and still under development. At present, heating is provided by individual fuel boilers. On the other hand, the campus has a geothermal resource in its borders with a temperature of 33 °C. Because of this low geothermal fluid temperature; heat pump district heating system is considered for the campus. As an alternative, fuel boiler district heating system is studied. Each heating system is simulated using hourly outdoor temperature data. For the simulations, a control system with constant flow rate and variable return water temperature is used and the main control parameter is the indoor temperature. Various heating regime alternatives have been studied for heat pump district heating system for the various condenser outlet temperature and geothermal fluid flow rate, and two of these alternatives are given in this study. Furthermore, economic analysis has also been done for each heating system alternative based on investment and operational costs. Results indicate that heat pump district heating system has the highest investment but lowest operational cost. The alternatives are evaluated according to internal rate of return method, which shows the profit of the investment and resulted that, the heat pump district heating system has minimum 3.02% profit comparing with the fuel boiler district heating system at the end of the 20-year period.
  • Article
    Citation - WoS: 30
    Citation - Scopus: 36
    Overview of Kizildere Geothermal Power Plant in Turkey
    (Elsevier Ltd., 2004) Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; Hepbaşlı, Arif; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Achieving sustainable development is a target that is now widely seen as important in worldwide public opinion. In this context, the utilization of renewable energy resources such as solar, geothermal and wind energy appears to be one of the most efficient and effective ways of achieving this target. Recently, power generation from geothermal energy has become of big importance in Turkey, which is located on the Mediterranean sector of the Alpine-Himalayan Tectonic Belt and is among the first seven countries in abundance of geothermal resources around the world. The main objective in doing the present study is twofold, namely: (a) to investigate Turkey's geothermal energy potential for power generation and (b) to overview the Denizli-Kizildere geothermal power plant (DKGPP) with an installed capacity of 20.4 MWe, which is at present the only operating geothermal power plant of Turkey. Based on the drilling data, which have been gathered to date, Turkey's geothermal energy potential for power generation is determined to be 764.81 MWe. Electricity generation projections of Turkey are also 500 MWe from Germencik, Kizildere, Tuzla and several of the other fields by the year 2010 and 1000 MWe by 2020. The Denizli-Kizildere geothermal field has an estimated capacity of 200 MWe. The DKGPP was put into operation in 1984 and has been operated since then. It produced an electrical energy of 89,597 MWh in 2001, representing an electric power of 10.6 MWe in the same year. Present applications have shown that in Turkey, geothermal energy is a promising alternative and can make a significant contribution towards reducing the emission of greenhouse gases. As the public recognizes the projects, the progress will continue.