Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
5 results
Search Results
Article Citation - WoS: 3Citation - Scopus: 3Quasi-Static and Dynamic Brazilian Testing and Failure Analysis of a Deer Antler in the Transverse To the Osteon Growth Direction(Elsevier, 2023) Orhan, Mehmet; Sarıkaya, Mustafa Kemal; Taşdemirci, Alper; Tuncer, Can; Güden, MustafaThe transverse tensile strength of a naturally fallen red deer antler (Cervus Elaphus) was determined through indirect Brazilian tests using dry disc-shape specimens at quasi-static and high strain rates. Dynamic Brazilian tests were performed in a compression Split-Hopkinson Pressure Bar. Quasi-static tensile and indirect Brazilian tests were also performed along the osteon growth direction for comparison. The quasi-static transverse tensile strength ranged 31.5–44.5 MPa. The strength increased to 83 MPa on the average in the dynamic Brazilian tests, proving a rate sensitive transverse strength. The quasi-static tensile strength in the osteon growth direction was however found comparably higher, 192 MPa. A Weibull analysis indicated a higher tensile ductility in the osteon growth direction than in the transverse to the osteon growth direction. The microscopic analysis of the quasi-static Brazilian test specimens (tensile strain along the osteon growth direction) revealed a micro-cracking mechanism operating by the crack deflection/twisting at the lacunae in the concentric lamellae region and at the interface between concentric lamellae and interstitial lamellae. On the other side, the specimens in the transverse direction fractured in a more brittle manner by the separation/delamination of the concentric lamellae and pulling of the interstitial lamellae. The detected increase in the transverse strength in the high strain rate tests was further ascribed to the pull and fracture of the visco-plastic collagen fibers in the interstitial lamellae. This was also confirmed microscopically; the dynamically tested specimens exhibited flatter fracture surfaces. © 2023 Elsevier LtdConference Object Citation - WoS: 1Citation - Scopus: 1Numerical and Experimental Studies of High Strain Rate Mechanical Behavior of E-glass/Polyester Composite Laminates(The American Society of Mechanical Engineers(ASME), 2010) Tunusoğlu, Gözde; Taşdemirci, Alper; Güden, Mustafa; Hall, Ian W.Quasi-static ∼10-3 s-1) and high strain rate (∼850 s-1) compression behavior of an E-glass/polyester composite was determined in the through-thickness and in-plane directions. In both directions, modulus and failure strength increased with increasing strain rate. Higher strain rate sensitivity for both elastic modulus and failure strength was observed in the in-plane direction. A numerical model was developed to investigate the compressive deformation and fracture of an E-glass/polyester composite. Excellent agreement was demonstrated for the case of high strain rate loading. Also, the fracture geometries were successfully predicted with the numerical model.Conference Object Off-Axis Properties of Cross-Ply Metal Matrix Composites at Quasi-Static and High Strain Rates(Elsevier Ltd., 2011) Hall, Ian W.; Taşdemirci, Alper; Kara, AliCylindrical samples of a 0/90° cross-ply Nextel 610™/A1-6061 (∼55Vf%) metal matrix composite have been subjected to compression testing at quasi-static and high strain rates over a range of angles between 0° and ±45° with respect to the principal fiber directions. The results, combined with testing in the longitudinal, transverse and through thickness directions, provide a detailed description of the response of such composites over a wide range of orientations. In addition, metallographic and fractographic studies along with high-speed camera records provide detailed information about the sequence of deformation events leading to fracture. Results confirm not only the strong dependence of mechanical properties upon orientation but also the critical importance of precise fiber alignment and processing in obtaining the desired theoretical properties. A misalignment of 10° was sufficient to cause an -40% decrease in maximum stress and the properties were found to vary by >70% over the orientations investigated. The high strain rate properties were generally significantly greater than those measured quasi-statically. A numerical model based on the commercial explicit finite element code LS-DYNA was used to investigate the compressive deformation and fracture of the composite. Experimental results are compared with those of the numerical model. © 2011 Published by Elsevier Ltd.Article Citation - WoS: 9Citation - Scopus: 9Quasi-Static and High Strain Rate Properties of a Cross-Ply Metal Matrix Composite(Elsevier Ltd., 2009) Hall, Ian W.; Taşdemirci, Alper; Derrick, J.A series of compression tests has been carried out at quasi-static and high strain rates on cylindrical samples of an alumina fiber/Al-6061 metal matrix composite. The composite plates were prepared with fibers in the 0°, 0/90° and ±45° orientations. It was found that the mechanical properties were strongly dependent upon the imposed strain rate, with fracture stress increases of >50% being noted for several orientations at high strain rates: these increases are not believed to be related to strain rate sensitivity of either the matrix or fibers but to arise from the inertia of fragments which remain in place after fracture and continue to bear load. Also, and in contradiction to behavior anticipated from the rule of mixtures, it was found that 0/90° samples exhibited properties superior to those of 0° unidirectional samples. High-speed photography was used to confirm the sequence of deformation and fracture events at high strain rate. © 2008 Elsevier B.V. All rights reserved.Article Citation - WoS: 12Citation - Scopus: 12The Effect of Strain Rate on the Compressive Deformation Behavior of a Sintered Ti6al4v Powder Compact(Elsevier Ltd., 2008) Taşdemirci, Alper; Hızal, Alpay; Altındiş, Mustafa; Hall, Ian W.; Güden, MustafaThe high strain rate (220–550 s−1) and quasi-static (0.0016 s−1) compression deformation behavior of a sintered Ti6Al4V powder compact was investigated. The compact was prepared using atomized spherical particles (100–200 μm) and contained 38 ± 1% porosity. The deformation sequences of the tested samples were further recorded by high speed camera and analyzed as a function of strain. The failure of the compact, which was found to be similar in the studied high strain rate and quasi-static strain rate testing regimes, occurs through particle decohesion along the surface of the two cones in a ductile (dimpled) mode consisting of void initiation and growth and by void coalescence in the interparticle bond region. The effect of strain rate was to increase the flow stress and compressive strength of the compact while the critical strain corresponding to the maximum stress was shown to be strain rate independent.
