Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 6 of 6
  • Article
    Citation - Scopus: 3
    Development of Chrono-Spectral Gold Nanoparticle Growth Based Plasmonic Biosensor Platform
    (Elsevier, 2024) Sözmen, Alper Baran; Elveren, Beste; Erdoğan, Duygu; Mezgil, Bahadır; Baştanlar, Yalın; Yıldız, Ümit Hakan; Arslan Yıldız, Ahu
    Plasmonic sensor platforms are designed for rapid, label-free, and real-time detection and they excel as the next generation biosensors. However, current methods such as Surface Plasmon Resonance require expertise and well-equipped laboratory facilities. Simpler methods such as Localized Surface Plasmon Resonance (LSPR) overcome those limitations, though they lack sensitivity. Hence, sensitivity enhancement plays a crucial role in the future of plasmonic sensor platforms. Herein, a refractive index (RI) sensitivity enhancement methodology is reported utilizing growth of gold nanoparticles (GNPs) on solid support and it is backed up with artificial neural network (ANN) analysis. Sensor platform fabrication was initiated with GNP immobilization onto solid support; immobilized GNPs were then used as seeds for chrono-spectral growth, which was carried out using NH2OH at varied incubation times. The response to RI change of the platform was investigated with varied concentrations of sucrose and ethanol. The detection of bacteria E.coli BL21 was carried out for validation as a model microorganism and results showed that detection was possible at 102 CFU/ml. The data acquired by spectrophotometric measurements were analyzed by ANN and bacteria classification with percentage error rates near 0% was achieved. The proposed LSPR-based, label-free sensor application proved that the developed methodology promises utile sensitivity enhancement potential for similar sensor platforms. © 2024 The Author(s)
  • Article
    Citation - WoS: 5
    Citation - Scopus: 4
    Polarity Induced Vapochromism and Vapoluminescence of Polythiophene Derivatives for Volatile Organic Compounds Classification
    (Elsevier, 2023) Karabacak, Soner; Qun, David Lee Chao; Ammanath, Gopal; Yeasmin, Sanjida; Yağmurcukardeş, Mehmet; Palaniappan, Alagappan; Liedberg, Bo; Yıldız, Ümit Hakan
    Polarity induced vapochromic and vapoluminescent properties of cationic poly-3-alkoxythiophene derivatives (PT) casted on polyvinylidene fluoride (PVDF) membranes are reported. PT with six different pendant groups are designed to differentially interact with volatile organic compounds (VOC) of varying polarities, thereby enabling their classification. PT exhibit a rapid vapochromic response with a concurrent modulation of vapoluminescence due to the non-covalent cation-? interactions between the pendant groups and the PT backbone. Adsorption of VOC on pendant groups alters the conformation of PT backbone, thus resulting in an increase in intensity and blue shifting of fluorescence emission within the visible spectrum. The vapoluminescent responses are found to be more sensitive with a limit of detection (LOD) of ?7 ppm and a wider dynamic range as compared to the vapochromic responses with a LOD of ?60 ppm for the detection of a model VOC: chloroform. Notably, all the PT illustrate an instantaneous recovery of colour and luminescence upon desorption of VOC. PT interaction with VOC of varying polarities was ascertained using density functional theory (DFT) and principal component analysis (PCA) methodologies. In summary, the polarity induced vapochromic and vapoluminescent properties of PT could yield a selective and sensitive vapochromic and fluorometric dual-mode VOC detection platform. © 2023
  • Article
    Citation - WoS: 35
    Citation - Scopus: 44
    Current Trends and Challenges in Point-Of Urinalysis of Biomarkers in Trace Amounts
    (Elsevier, 2022) Yeasmin, Sanjida; Ammanath, Gopal; Önder, Ahmet; Yan, Evelias; Yıldız, Ümit Hakan; Palaniappan, Alagappan; Liedberg, Bo
    Urinalysis enables non-invasive point-of-care (POC) testing of numerous biomarkers at their physiological and elevated levels, obviating the need for sophisticated equipment or trained personnel. POC urinalysis is used to identify biomarkers that are rich in urine (greater than 1 μM), such as lactate, uric acid, glucose, ions, and adenosine. Urine also contains biomarkers such as small molecules, nucleic acids, neurotransmitters, and drugs in trace amounts (less than 1 μM). These biomarkers are of significant importance for health care monitoring, diagnosis of various disorders (cancer, metabolic diseases, etc.) and illicit drug control (cocaine, steroids, etc.). While POC detection of urinary biomarkers at higher concentration (μM to mM) levels is feasible, direct assaying of biomarkers in nM to fM levels is challenging, as assay responses are typically masked by interferences from the urine sample matrix. This report is a consolidated review of emerging trends and challenges in the POC urinalysis for detecting biomarkers that are less abundant in urine. The sensing mechanisms, analytical device fabrication, discrete and integrated sample pre-treatment procedures for POC assaying of urinary markers in trace amounts are elaborated. Subsequently, the utilization of smart data analytics for facilitating personalized urinalysis is presented. A comprehensive outlook on associated challenges in POC urinalysis of biomarkers in trace amounts is further provided, which would facilitate the advancement of POC urinalysis for a wide range of healthcare applications.
  • Article
    Citation - WoS: 43
    Citation - Scopus: 46
    Glucuronoxylan-Based Quince Seed Hydrogel: a Promising Scaffold for Tissue Engineering Applications
    (Elsevier, 2021) Güzelgülgen, Meltem; Özkendir İnanç, Dilce; Yıldız, Ümit Hakan; Arslan Yıldız, Ahu
    Natural gums and mucilages from plant-derived polysaccharides are potential candidates for a tissue-engineering scaffold by their ability of gelation and biocompatibility. Herein, we utilized Glucuron-oxylanbased quince seed hydrogel (QSH) as a scaffold for tissue engineering applications. Optimization of QSH gelation was conducted by varying QSH and crosslinker glutaraldehyde (GTA) concentrations. Structural characterization of QSH was done by Fourier Transform Infrared Spectroscopy (MR). Furthermore, morphological and mechanical investigation of QSH was performed by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The protein adsorption test revealed the suitability of QSH for cell attachment. Biocompatibility of QSH was confirmed by culturing NIH-3T3 mouse fibroblast cells on it. Cell viability and proliferation results revealed that optimum parameters for cell viability were 2 mg mi(-1)of QSH and 0.03 M GTA. SEM and DAPI staining results indicated the formation of spheroids with a diameter of approximately 300 pm. Furthermore, formation of extracellular matrix (ECM) microenvironment was confirmed with the Collagen Type-I staining. Here, it was demonstrated that the fabricated QSH is a promising scaffold for 3D cell culture and tissue engineering applications provided by its highly porous structure, remarkable swelling capacity and high biocompatibility. (C) 2021 Published by Elsevier B.V.
  • Article
    Citation - WoS: 39
    Citation - Scopus: 37
    Flow-Through Colorimetric Assay for Detection of Nucleic Acids in Plasma
    (Elsevier, 2019) Ammanath, Gopal; Yeasmi, Sanjida; Srinivasulu, Yuvasri; Vats, Mukti; Cheema, Jamal Ahmed; Nabilah, Fairuz; Liedberg, Bo; Yıldız, Ümit Hakan
    A flow-through colorimetric assay for detection of nucleic acids in plasma is reported. The proposed assay features an array of four polyvinylidene fluoride (PVDF) membranes impregnated with cationic poly (3-alkoxy-4-methylthiophene) (PT) as an optical reporter. The sensing strategy is based on monitoring the changes in optical properties of PT, upon complexation with target nucleic acids in the presence and in the absence of their corresponding complementary peptide nucleic acids (PNAs). As a proof of concept, the proposed methodology is validated using two biomarkers; lung cancer associated microRNA (mir21) and hepatitis B virus DNA (HBV-DNA). The flow-through colorimetric assay enabled detection of mir21 and HBV-DNA in plasma without requiring tedious sample pre-treatment and clean up protocols. Colorimetric responses for mir21 and HBV-DNA were obtained at nanomolar concentrations over five orders of magnitudes (from 1 nM to 10 mu M), with a limit of detection of -0.6 nM and -2 nM in DI water and plasma, respectively. A logic gate system was developed to utilize the colorimetric assay responses as inputs for discrimination of mir21 and HBV-DNA and subsequently to obtain a profile of nucleic acids in samples that exceed respective clinical threshold limits, thereby enabling rapid and point of care (POC) disease diagnosis. Furthermore, the proposed methodology can be utilized for detection of a large number of nucleic acids in plasma by extending the array of PT impregnated membranes incorporated with their corresponding complementary PNAs. (C) 2019 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 17
    Citation - Scopus: 19
    Pixelated Colorimetric Nucleic Acid Assay
    (Elsevier, 2020) Aydın, Hakan Berk; Cheema, Jamal Ahmed; Arnmanath, Gopal; Toklucu, Cihan; Yücel, Müge; Özenler, Sezer; Yıldız, Ümit Hakan
    Conjugated polyelectrolytes (CPEs) have been widely used as reporters in colorimetric assays targeting nucleic acids. CPEs provide naked eye detection possibility by their superior optical properties however, as concentration of target analytes decrease, trace amounts of nucleic acid typically yield colorimetric responses that are not readily perceivable by naked eye. Herein, we report a pixelated analysis approach for correlating colorimetric responses of CPE with nucleic acid concentrations down to 1 nM, in plasma samples, utilizing a smart phone with an algorithm that can perform analytical testing and data processing. The detection strategy employed relies on conformational transitions between single stranded nucleic acid-cationic CPE duplexes and double stranded nucleic acid-CPE triplexes that yield distinct colorimetric responses for enabling naked eye detection of nucleic acids. Cationic poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1-aminium bromide] is utilized as the CPE reporter deposited on a polyvinylidene fluoride (PVDF) membrane for nucleic acid assay. A smart phone application is developed to capture and digitize the colorimetric response of the individual pixels of the digital images of CPE on the PVDF membrane, followed by an analysis using the algorithm. The proposed pixelated approach enables precise quantification of nucleic acid assay concentrations, thereby eliminating the margin of error involved in conventional methodologies adopted for interpretation of colorimetric responses, for instance, RGB analysis. The obtained results illustrate that a ubiquitous smart phone could be utilized for point of care colorimetric nucleic acids assays in complex matrices without requiring sophisticated software or instrumentation.