  • Article
    Citation - WoS: 5
    Citation - Scopus: 6
    Active Heat Transfer Enhancement by Interface-Localized Liquid Dielectrophoresis Using Interdigitated Electrodes
    (Elsevier, 2022) Yenigün, Onur; Barışık, Murat
    We introduced an active heat transfer control between graphene and water using interdigitated electrodes (IDEs). Oppositely charged co-planer electrodes embedded on a graphene surface created a non-uniform electric field. Resulted interface localized liquid dielectrophoresis (LDEP) perpendicular to surface enhanced the water/graphene coupling and decreased interfacial thermal resistance (ITR) substantially. We correlated the theoretical calculations of average electric field strength near surface with Kapitza values measured at corresponding electrode configurations. We obtained a unified linear variation of Kapitza as a function of average electric strength independent of electrode size and charge. By increasing the electric field strength, we measured up to 96% decrease of Kapitza near electrodes. Since the IDEs generated electric field was only interface localized, it required lower electrode charges than any parallel-plate capacitor systems. We showed that ITR remains effective in heat transfer behavior for systems as big as 100nm such that interface localized electric field can at least increase the heat removal 50% by eliminating the ITR from both graphene/water interfaces of a channel system. By converting hydrophobic few-layer graphene to super-hydrophilic condition with ultra-low Kapitza, current results are important for graphene-based materials considered for the solution of the thermal management problem of current and next generation micro/nano-electronics.
  • Conference Object
    Effect of Electric Field on Interfacial Thermal Resistance Between Silicon and Water at Nanoscales
    (Avestia Publishing, 2019) Yenigün, Onur; Barışık, Murat
    In this study, heat transfer rate of a nano-confined liquid is controlled by applying an electric field parallel to the heat transfer direction. Molecular Dynamics simulations are performed for deionized water confined between silicon slabs, where their surfaces oppositely charged to create an electric field perpendicular to the silicon wall to promote the electrowetting. Electric field strengths used in this study are 0, 0.18 and 0.35 V/nm. To investigate the effect of electric field on heat transfer, first water density profiles near the silicon walls are examined. Results shows that by applying electric field, water molecules near the silicon walls develop layering, which indicates the increased solid/liquid coupling. With the increasing electric field strength, an increase in the peak of the density layering is observed. Furthermore, heat transfer at the solid/liquid interface is characterized with the Kapitza length values. The results show that applying electric field reduces the interfacial thermal resistance between water and silicon due to the increased solid/liquid coupling and doubles the total heat flux. © 2019, Avestia Publishing.
  • Article
    Citation - WoS: 24
    Citation - Scopus: 28
    Atomic Density Effects on Temperature Characteristics and Thermal Transport at Grain Boundaries Through a Proper Bin Size Selection
    (American Institute of Physics, 2016) Vo, Truongquoc; Barışık, Murat; Kim, Bohung
    This study focuses on the proper characterization of temperature profiles across grain boundaries (GBs) in order to calculate the correct interfacial thermal resistance (ITR) and reveal the influence of GB geometries onto thermal transport. The solid-solid interfaces resulting from the orientation difference between the (001), (011), and (111) copper surfaces were investigated. Temperature discontinuities were observed at the boundary of grains due to the phonon mismatch, phonon backscattering, and atomic forces between dissimilar structures at the GBs. We observed that the temperature decreases gradually in the GB area rather than a sharp drop at the interface. As a result, three distinct temperature gradients developed at the GB which were different than the one observed in the bulk solid. This behavior extends a couple molecular diameters into both sides of the interface where we defined a thickness at GB based on the measured temperature profiles for characterization. Results showed dependence on the selection of the bin size used to average the temperature data from the molecular dynamics system. The bin size on the order of the crystal layer spacing was found to present an accurate temperature profile through the GB. We further calculated the GB thickness of various cases by using potential energy (PE) distributions which showed agreement with direct measurements from the temperature profile and validated the proper binning. The variation of grain crystal orientation developed different molecular densities which were characterized by the average atomic surface density (ASD) definition. Our results revealed that the ASD is the primary factor affecting the structural disorders and heat transfer at the solid-solid interfaces. Using a system in which the planes are highly close-packed can enhance the probability of interactions and the degree of overlap between vibrational density of states (VDOS) of atoms forming at interfaces, leading to a reduced ITR. Thus, an accurate understanding of thermal characteristics at the GB can be formulated by selecting a proper bin size.