    New Approach for Consideration of Adsorption/Desorption Data
    (Elsevier Ltd., 2011) Baleanu, Mihaela Cristina; Nigmatullin, Raoul R.; Okur, Salih; Ocakoğlu, Kasım
    In this paper we proposed a new approach to modify the Langmuir model by considering nonlinear effects such as diffusion of water molecules in/out of an adsorbing film for humidity adsorption and desorption kinetics. The model was tested on the humidity adsorption and desorption data of a spin coated 50. nm thick Ruthenium polypridyl complex (Ru-PC K314) film, measured under relative humidity between 11% and 97% using by Quartz Crystal Microbalance (QCM) technique. © 2011 Elsevier B.V.
  • Article
    Citation - WoS: 17
    Citation - Scopus: 21
    Humidity Sensing Properties of Chitosan by Using Quartz Crystal Microbalance Method
    (American Scientific Publishers, 2012) Havare, A. Kemal; İlgü, Hüseyin; Okur, Salih; Şanlı Mohamed, Gülşah
    Humidity adsorption kinetics of chitosan films was investigated by quartz crystal microbalance (QCM) technique. In this study, chitosan was synthesized from chitin by deacetylation process in 2.0% (v/v) acetic acid solution and then coated on QCM to measure humidity response. The Langmuir model was used to determine the adsorption rates and Gibbs free energy for various relative humidity between 11% and 94%. The average Gibbs free energy for adsorption was obtained as 12.93 kJ/mol. Our reproducible experimental results show that chitosan films are very sensitive to relative humidity changes at room temperature. Copyright © 2012 American Scientific Publishers All rights reserved.
  • Article
    Citation - WoS: 34
    Citation - Scopus: 37
    Humidity Adsorption Kinetics of Water Soluble Calix[4]arene Derivatives Measured Using Qcm Technique
    (Elsevier Ltd., 2010) Okur, Salih; Kuş, Mahmut; Özel, Faruk; Yılmaz, Mustafa
    We report on the optimization and characterization of water soluble calix[4]arene derivative as a humidity sensor based on quartz crystal microbalance technique. The moisture adsorption and desorption kinetics of calix[4]arene were investigated. The Langmuir model was used to determine the kinetic parameters such as adsorption, desorption rates and Gibbs free energy between relative humidity between 29% and 78%. Reproducible experimental results were obtained showing that water soluble calix[4]arene films have a great potential for humidity sensing applications at room temperature operations. © 2009 Elsevier B.V. All rights reserved.
  • Article
    Adsorption Equilibrium and Dynamics of Lactase/Cm-sephadex System
    (Kluwer Academic Publishers, 1995) Harsa, Hayriye Şebnem; Göksungur, Yekta; Güvenç, Ulgar
    Partitioning behaviour and adsorption isotherms of lactase/CM-Sephadex system at equilibrium were investigated together with the adsorption kinetics in this study. Maximum adsorption was obtained at the pH values between 5.5–6.0. Adsorption isotherm was a close fit to the Langmuir model.