    Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey
    (Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    Mosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 14
    Thermal Simulation of Retrofits To Existing Mass Housing in Turkey for Energy Efficiency
    (Sila Science, 2011) Yıldız, Yusuf; Durmuş Arsan, Zeynep
    Energy consumption in the existing residential building stock in Turkey is currently excessive. Mass housing, comprising a major portion of the officially-registered residential stock, carries enormous potential for energy savings even in the short run. This paper describes a case study in a mass housing area in Izmir, Turkey, in order to demonstrate the possibility of significant energy savings by implementing case-specific energy-efficient retrofitting scenarios and relating them with the payback periods. Building energy analysis software was used to examine thirteen scenarios consisting of various combinations of four main retrofitting options: addition of extra insulation for building envelope, replacement of existing glazing, regulation of air infiltration rate and indoor set point temperature. These scenarios revealed that annual energy savings of up to 62% are achievable and that the customer payback period for the best retrofitting scenario is 34 years.