Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
8 results
Search Results
Now showing 1 - 8 of 8
Review Citation - WoS: 13Citation - Scopus: 13A Review on Battery Thermal Management Strategies in Lithium-Ion and Post-Lithium Batteries for Electric Vehicles(Yıldız Technical University, 2023) Güngör, Şahin; Göçmen, Sinan; Çetkin, ErdalElectrification on transportation and electricity generation via renewable sources play a vital role to diminish the effects of energy usage on the environment. Transition from the conven- tional fuels to renewables for transportation and electricity generation demands the storage of electricity in great capacities with desired power densities and relatively high C-rate values. Yet, thermal and electrical characteristics vary greatly depending on the chemistry and struc- ture of battery cells. At this point, lithium-ion (Li-ion) batteries are more suitable in most applications due to their superiorities such as long lifetime, high recyclability, and capacities. However, exothermic electrochemical reactions yield temperature to increase suddenly which affects the degradation in cells, ageing, and electrochemical reaction kinetics. Therefore, strict temperature control increases battery lifetime and eliminates undesired situations such as lay- er degradation and thermal runaway. In the literature, there are many distinct battery thermal management strategies to effectively control battery cell temperatures. These strategies vary based on the geometrical form, size, capacity, and chemistry of the battery cells. Here, we focus on proposed battery thermal management strategies and current applications in the electric vehicle (EV) industry. In this review, various battery thermal management strategies are doc- umented and compared in detail with respect to geometry, thermal uniformity, coolant type and heat transfer methodology for Li-ion and post-lithium batteries.Article Citation - WoS: 12Citation - Scopus: 11Inverted Fins for Cooling of a Non-Uniformly Heated Domain(Yıldız Teknik Üniversitesi, 2015) Çetkin, ErdalThis paper shows that the peak temperature of a non-uniformly heated region can be decreased by embedding high-conductivity tree-shaped inserts which is in contact with a heat sink from its stem. The volume fraction of the high-conductivity material is fixed, and so is the volume of the solid region. The length scale of the solid domain is L. Inside there is a cube-shaped region with length scale of 0.1L and heat production 100 times greater than the rest of the domain. The location of this hot spot was varied to uncover how its location affects the peak temperature and the design of inverted fins, i.e. highconductivity tree-shaped inserts. The volume fraction of the high-conductivity tree was varied for number of bifurcation levels of 0, 1 and 2. This showed that increasing the number of the bifurcation levels decreases the peak temperature when the volume fraction decreases. The optimal diameter ratios and optimal bifurcation angles at the each junction level are also documented. Y-shaped trees promise smaller peak temperatures than T-shaped trees. The location of the vascular tree in the z direction also affects the peak temperature when the heat generation is non-uniform. In addition, the peak temperature is minimum when z = 0.65L even though the hot spot is located on z = 0.75L.Article Citation - WoS: 3Citation - Scopus: 4Constructal Structures for Self-Cooling: Microvascular Wavy and Straight Channels(Yıldız Teknik Üniversitesi, 2015) Çetkin, ErdalThis paper shows that a conductive domain which is subjected to heating from its bottom can be cooled with embedded microvascular cooling channels in it. The volume of the domain and the coolant are fixed. The actively cooled domain is mimicked from the human skin (which regulates temperature with microvascular blood vessels). The effect of the shape of cooling channels (sinusoidal or straight) and their locations in the direction perpendicular to the bottom surface on the peak and average temperatures are studied. In addition, the effect of pressure difference in between the inlet and outlet is varied. The pressure drop in the sinusoidal channel configurations is greater than the straight channel configurations for a fixed cooling channel volume. The peak and average temperatures are the smallest with straight cooling channels located at y = 0.7 mm. Furthermore, how the cooling channel configuration should change when the heat is generated throughout the volume is studied. The peak and average temperatures are smaller with straight channels than the sinusoidal ones when the pressure drop is less than 420 Pa, and they become smaller with sinusoidal channel configurations when the pressure drop is greater than 420 Pa. In addition, the peak and average temperatures are the smallest with sinusoidal channels for a fixed flow rate. Furthermore, the peak temperatures for multiple cooling channels is documented, and the multiple channel configurations promise to the smallest peak temperature for a fixed pressure drop value. This paper uncovers that there is no optimal cooling channel design for any condition, but there is one for specific objectives and conditions.Article Citation - WoS: 1Citation - Scopus: 1Constructal Structures With and Without High-Conductivity Inserts for Self-Cooling(International Information and Engineering Technology Association, 2016) Çetkin, ErdalHere we show how a heat generating domain can be gained self-cooling capability with embedded cooling channels and with and without high-conductivity fins. The volume of the heat generating domain is fixed, so is the overall volume of the cooling channels and high-conductivity inserts. Even though the coolant volume decreases with embedded high-conductivity fins, the peak temperature also decreases with high-conductivity inserts. The peak temperature is affected by the location, shape and complexity of the fins and the volume fraction. This paper documents how these degrees of freedoms should be changed in order to minimize peak temperature. This paper also discusses how the volume fraction affects each fin shape in order to minimize the peak temperature. This paper uncovers that the fins should be distributed non-equidistantly, and that high-conductivity material should be inserted as fins (bulks of high-conductivity materials) rather than uniform distribution in the domain. This paper concludes that the overall thermal conductance of a heat generating domain can be maximized by freely morphing the shape of the high-conductivity material. The optimal design exists for given conditions and assumptions, and this design should be morphed when conditions and assumptions change. This conclusion is in accord with the constructal law. Each optimal design for given conditions and assumptions is the constructal designArticle Citation - WoS: 3Citation - Scopus: 4The Effect of Cooling on Mechanical and Thermal Stresses in Vascular Structures(Yıldız Teknik Üniversitesi, 2018) Çetkin, ErdalHere, we show how the vascular channel configuration and its shape affect the mechanical strength which is simultaneously subjected to heating and mechanical load. The material properties were defined as functions of temperature. The effect of channel cross-section on the coolant mass flow rate, peak temperature and peak stresses are documented. The results show that the resistances to flow of stresses and fluid is minimum with the circular channels while the resistance to the heat flow is the smallest with semi-circular channels. In addition, morphing the vascular design provides almost the smallest resistance to the heat flow with circular channels (0.3% difference in the peak temperature). This shows that even the convective resistances are the smallest with circular-cross section, overall thermal resistance is smaller in semi-circular design for the fixed fluid volume. The peak stress is smaller with hybrid design than the parallel designs for the entire pressure drop range. In addition, the effects of mechanical load, heating rate and reference temperature on the stress distribution are also documented. Furthermore, the thermal and mechanical stresses are also documented separately, and then compared with the coupled solution cases. The chief result of this paper is that for a coupled system minimizing only one of the resistance terms is not sufficient, all the resistances considered simultaneously in order to uncover the best performing design. In coupled solutions, we documented the simulation results with temperature dependent material properties and the resistances to the heat and fluid flow is affected by the mechanical deformations. In addition, the results show that the designs should be free to vary, the unexpected designs can be the best performing designs for the given parameters and constraints. Therefore, the design parameters based on the experience does not always yield the best performing designs as the objectives and constraints vary.Article Citation - WoS: 3Citation - Scopus: 5Constructal Tree-Shaped Designs for Self-Cooling(Edizioni ETS, 2016) Yenigün, Onur; Çetkin, ErdalIn this paper, we show how a plate which is subjected to a heating load can be kept under an allowable temperature. Vascular channels in which coolant fluid flows have been embedded in the plate. Two types of vascular channel designs were compared: radial and tree-shaped. The effects of channel design on the thermal performance for different volume fractions (the fluid volume over the solid volume) are documented. Changing the design from radial to tree-shaped designs decreases the order of pressure drop. Hence increase in the order of the convection coefficient is achieved. However, treeshaped designs do not bath the entire domain. Therefore, we have inserted additional branches at the uncooled regions. Then, we have compared the peak temperatures of radial, traditional tree-shaped and improved tree-shaped designs. The effect of design on the maximum temperature shows that there should be an optimum design for a distinct set of boundary conditions, and this design should be varied as the boundary conditions change. This result is in accord with the constructal law, i.e. the shape should be varied in order to minimize resistances to the flows.Article Citation - WoS: 6Citation - Scopus: 6The Effect of Cavities and T-Shaped Assembly of Fins on Overall Thermal Resistances(International Information and Engineering Technology Association, 2017) Çetin, Eylem; Çetkin, ErdalIn this study, authors show that maximum excess temperature on a heat generating cylindrical solid domain can be minimized with numerically optimized rectangular cavities and T-shaped fins. The effect of the cavities and the fins on overall thermal resistances were compared while their volume fraction in a unit volume element is fixed. Furthermore, the designs correspond to the minimum thermal resistance were uncovered for two types of flows; parallel and cross-flow. The governing equations of the heat transfer and the fluid flow were solved simultaneously in order to show the effects of design on the flow characteristics and the thermal performance. Two-dimensional solution domain was used to uncover the thermal performance in cross-flow case because the flow direction is perpendicular to the heat transfer surface area of the heat generating domain. However, three-dimensional domain was used in parallel flow case because the fluid flows along the outer surface of the heat generating domain. For the cross-flow case, the results show that T-shaped assembly of fins with longer stem and shorter tributaries correspond to the lower peak temperature. In addition, the results also show that there is an optimal cavity shape that minimizes the peak temperature. This optimal shape becomes thinner when the number of the cavities increase. In parallel flow case, fins with thicker and shorter stem and longer tributaries correspond to the minimum excess temperature. In addition, the longer and thinner cavities increase the thermal performance in parallel flow case.Article Citation - WoS: 2Citation - Scopus: 2Vascular Structures for Smart Features: Self-Cooling and Self-Healing(Yıldız Teknik Üniversitesi, 2017) Çetkin, ErdalHere we show how smart features of self-cooling and self-healing can be gained to mechanical systems with embedded vascular structures. Vascular structures mimic the circulatory system of animals. Similar to blood distribution from heart to the animal body, vascular channels provide the distribution of coolant and/or healing agent from a point to the entire body of a mechanic system. Thus the mechanic system becomes capable of cooling itself under unpredictable heat attacks and capable of healing itself as cracks occur due to applied mechanical loads. These smart features are necessary for advanced devices, equipment and vehicles. The essential design parameter is vascularization in order to provide smart features. There are distinct configurations for vascularization such as radial, tree-shaped, grid and hybrids of these designs. In addition, several theories are available for the shape optimization of vascular structures such as fractal theory and constructal theory. Unlike fractal theory, constructal theory does not include constraints based on generic algorithms and dictated assumptions. Therefore, constructal theory approach is discussed in this paper. This paper shows how smart features can be gained to a mechanical system while its weight decreases and its mechanical strength increases simultaneously.
