Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - WoS: 10
    Citation - Scopus: 14
    Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals
    (Elsevier, 2023) Halıcı, Ömer Faruk; Demir, Uğur; Zabbar, Yassin; İlki, Alper
    The infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens.
  • Article
    Citation - WoS: 8
    Citation - Scopus: 13
    Masonry Buildings Subjected To Settlements: Half-Scale Testing, Detailed Measurements, and Insights Into Behaviour
    (Elsevier, 2023) Dalgıç, Korhan Deniz; Gülen, Burcu; Liu, Yiyan; Açıkgöz, Sinan; Burd, Harvey; Maraşlı, Muhammed; İlki, Alper
    Industry procedures to assess the risk of settlement-induced damage to masonry buildings ignore key aspects of the problem, such as the influences of building weight, façade openings, and floor structures. Experimental data are needed to characterise the influence of these aspects on damage. This paper describes tests on three brick masonry half-scale building models subjected to settlements. The use of scaling rules in choosing the model materials and kentledge, the settlement apparatus, and the cross-validation of displacement and strain measurements are presented. Comparative evaluation of building responses show that: (i) the distribution of building weight and the resulting in-situ stresses play a key role in determining compliance to settlements, (ii) openings make the structure vulnerable to cracking and (iii) floor slabs stiffen and strengthen the building and prevent the formation of damage in the upper floors, leading to a concentration of damage at the ground storey.
  • Article
    Citation - WoS: 61
    Citation - Scopus: 60
    Performance of Structures in Izmir After the Samos Island Earthquake
    (Springer, 2021) Yakut, Ahmet; Sucuoğlu, Haluk; Binici, Barış; Canbay, Erdem; Dönmez, Cemalettin; İlki, Alper; Caner, Alp
    The October 30, 2020 Earthquake caused unexpectedly significant damage in Izmir considering its distance to the city. This paper evaluates the recorded ground motions, summarizes the performance of structures affected from the earthquake with emphasis on the reasons of damage. A detailed damage assessment was carried out by the Earthquake Engineering Research Center of Middle East Technical University to compile data on the damage of RC and masonry buildings. It was observed that majority of the damage was concentrated in the Bayrakli district due to its peculiar soil properties where many 7-10 story mid-rise RC buildings suffered heavy damage and collapse. The level of amplified ground motions combined with deficiencies of apparently non-code compliant buildings exacerbated the damage. The main reasons of damage were mainly attributed to the presence of soft stories, lack of proper detailing, poor construction quality, presence of heavy overhangs, and hence significant lack of code-compliance in essence. The influence of infill walls on seismic performance of deficient and inadequate buildings was clearly seen in this earthquake. This paper also discusses seismic code requirements in effect and their influence on the observed building performance. The recorded ground motions were compared with the code spectra to evaluate the performance of the buildings. The code response spectra were found to be well above the recorded ground motion spectra at the sites where significant damage was observed.