Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
2 results
Search Results
Now showing 1 - 2 of 2
Article Citation - WoS: 32Citation - Scopus: 32Luminescent Device for the Detection of Oxidative Stress Biomarkers in Artificial Urine(American Chemical Society, 2018) Ammanath, Gopal; Yıldız, Ümit Hakan; Palaniappan, Alagappan; Liedberg, BoA luminescent paper-based device for the visual detection of oxidative stress biomarkers is reported. The device consists of a polyvinylidene fluoride membrane impregnated with poly(3-alkoxy-4-methylthiophene) (PT) for colorimetric detection. 8-hydroxy-2′-deoxyguanosine (8-OHdG), a biomarker associated with oxidative stress, is used as a model system for validating the proposed methodology. The detection strategy is based on monitoring the changes in optical properties of PT associated with its conformational changes upon interaction with an aptamer in the presence and in the absence of 8-OHdG. Fluorometric and colorimetric monitoring revealed linear responses for 8-OHdG concentrations between 50 pM and 500 nM (∼14 pg/mL to 140 ng/mL), with limits of detection of ∼300 pM and ∼350 pM, respectively for (n = 3). Colorimetric responses in artificial urine ascertained rapid, sensitive, and selective detection of 8-OHdG at clinically relevant (pM to nM) concentration levels. Furthermore, the proposed methodology enables point-of-care diagnostics for oxidative stress without requiring sophisticated instrumentation.Article Citation - WoS: 19Citation - Scopus: 19Visual Detection of Al3+ Ions Using Conjugated Copolymer-Atp Supramolecular Complex(Elsevier Ltd., 2016) Tu, Meng-Che; Rajwar, Deepa; Ammanath, Gopal; Alagappan, Palaniappan; Yıldız, Ümit Hakan; Liedberg, BoA colorimetric Al3+ sensor based on fluorescence recovery of a conjugated copolymer-ATP complex is proposed. An optimized ratio of two polythiophene (PT) monomers is utilized to synthesize copolymer (CP) that yielded maximized colorimetric response for Al3+ in deionized (DI) and tap water. The electrostatic disassembly of CP-ATP upon addition of Al3+ led to an evident visual color change. The lowest concentration of Al3+ for naked eye observation is around 4 μM, which is below the threshold levels in drinking water according to European Economic Community (EEC) standard. Besides, the proposed assay showed a similar response to Al3+ in tap water. The proposed methodology showed selective and sensitive detection for Al3+ in analytically relevant concentration ranges without involving sophisticated instrumentation, illustrating the applicability for on-site drinking water monitoring.
