Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 4 of 4
  • Article
    Citation - WoS: 4
    Citation - Scopus: 4
    Estimation of Heat Production Rate Using Thermal Data During Exercise in Indoor Environments: a Study of Heat Storage Rate in Male Athletes
    (Springer, 2024) Balci, Gorkem Aybars; Avci, Ali Berkay; Colakoglu, Muzaffer; Basaran, Tahsin; Balcı, Görkem Aybars; Avcı, Ali Berkay; Çolakoğlu, Muzaffer; Başaran, Tahsin
    The increasing preference for indoor exercise spaces highlights the relationship between indoor thermal environments and physiological responses, particularly concerning thermal comfort during physical activity. Determining the metabolic heat production rate during exercise is essential for optimizing the thermal comfort, well-being, and performance of individuals engaged in physical activities. This value can be determined during the activity using several methods, including direct calorimetry measurement, indirect calorimetry that uses analysis of respiratory gases, or approximations using collected data such as speed, body mass, and heart rate. The study aimed to calculate the metabolic heat production rate by infrared thermal evaluation (ITE) based on the body's thermal balance approach and compare it with the values determined by indirect calorimetry (IC). Fourteen participants volunteered for the study, using a cycling ergometer in a controlled climatic chamber. After the familiarization sessions, maximal O-2 intake levels (VO2max) were determined through maximal graded exercise tests. Subsequently, constant work rate exercise tests were performed at 60% of VO2max for 20 min. The metabolic heat production rates were calculated by IC and ITE for each athlete individually. Respiratory gases were used to determine IC, while body skin and core temperatures, along with physical environmental data, were applied to calculate ITE using the human body thermal balance approximation of ASHRAE. According to the results, heat storage rates were misleading among the body's heat transfer modes, particularly during the first 8 min of the exercise. ITE showed a moderate level of correlation with IC (r: 0.03-0.86) with a higher level of dispersion relative to the mean (CV%: 12-84%). Therefore, a new equation (ITEnew) for the heat storage rates was proposed using the experimental data from this study. The results showed that ITEnew provided more precise estimations for the entire exercise period (p > 0.05). Correlations between ITEnew and IC values were consistently strong throughout the exercise period (r: 0.62-0.85). It can be suggested that ITEnew values can predict IC during the constant work rate steady-state exercise.
  • Article
    Citation - WoS: 1
    On-Site Measurements of Temperature and Humidity Conditions for the Comparison of Urban and Rural Sub-Spaces of Traditional Settlements: Historical City of Mugla, Turkey
    (Taylor & Francis, 2023) Timur, Barış Ali; Başaran, Tahsin; İpekoğlu, Başak
    One of the significant processes that ensures realistic determination of the energy needs of historical buildings is case-specific definition of their local microclimatic conditions. Accordingly, the aim of this study is to determine differences for the parameters of temperature and humidity in urban and rural sub-settlements of the historical city, Mugla/Turkey. Study method consists of on-site measurements of these variables in sub-settlements for comparisons. As a result, it was identified urban zone shows heat island characteristics with warmer, drier, and more stable conditions; while rural sub-settlement remains cooler, more humid, and more erratic. In parallel, calculated extents of these differences demonstrate the significance and necessity of on-site measurements and consequential microclimatic zoning of historical cities as conservation/planning tools for responding to the thermal needs of architectural heritage. A key application of these processes would be the establishment of local databases of case-specific weather data to be used in thermal simulation assessments.
  • Article
    Citation - WoS: 23
    Citation - Scopus: 25
    Analysing Visual Pattern of Skin Temperature During Submaximal and Maximal Exercises
    (Elsevier Ltd., 2016) Balcı, Görkem Aybars; Başaran, Tahsin; Çolakoğlu, Muzaffer
    Aims of this study were to examine our hypotheses assuming that (a) skin temperature patterns would differ between submaximal exercise (SE) and graded maximal exercise test (GXT) and (b) thermal kinetics of Tskin occurring in SE and GXT might be similar in a homogenous cohort. Core temperature (Tcore) also observed in order to evaluate thermoregulatory responses to SE and GXT. Eleven moderately to well-trained male athletes were volunteered for the study (age: 22.2 ± 3.7 years; body mass: 73.8 ± 6.9 kg; height: 181 ± 6.3 cm; body surface area 1.93 ± 0.1 m2; body fat: 12.6% ± 4.2%; V̇O2 max: 54 ± 9.9 mL min-1 kg-1). Under stabilized environmental conditions in climatic chamber, GXT to volitional exhaustion and 20-min SE at 60% of VO2 max were performed on cycle ergometer. Thermal analyses were conducted in 2-min intervals throughout exercise tests. Tskin was monitored by a thermal camera, while Tcore was recorded via an ingestible telemetric temperature sensor. Thermal kinetic analyses showed that Tskin gradually decreased till the 7.58 ± 1.03th minutes, and then initiated to increase till the end of SE (Rsqr = 0.97), while Tskin gradually decreased throughout the GXT (Rsqr = 0.89). Decrease in the level of Tskin during the GXT was significantly below from the SE [F (4, 40) = 2.67, p = 0.07, ηp 2 = 0.211]. In the meantime, Tcore continuously increased throughout the SE and GXT (p < 0.05). Both GXT and SE were terminated at very close final Tcore values (37.8 ± 0.3 °C and 38.0 ± 0.3 °C, respectively; p > 0.05). However, total heat energies were calculated as 261.5 kJ/m2 and 416 kJ/m2 for GXT and SE, respectively (p < 0.05). Thus, it seems that SE may be more advantageous than GXT in thermoregulation. In conclusion, Tcore gradually increased throughout maximal and submaximal exercises as expected. Tskin curves patterns found to be associated amongst participants at both GXT and SE. Therefore, Tskin kinetics may ensure an important data for monitoring thermoregulation in exercise.
  • Article
    Citation - WoS: 23
    Citation - Scopus: 28
    Thermal Analysis of the Domed Vernacular Houses of Harran, Turkey
    (SAGE Publications Inc., 2011) Başaran, Tahsin
    Minimum energy consumption and economic efficiency using local and recyclable materials is essential for achieving sustainability, considering the depletion of global energy sources. The Anatolian Peninsula presents a diverse range of local building construction techniques accumulated over centuries, which meet the criteria mentioned above. Due to richness of climatic variety and the influence of many civilisations throughout history, Anatolian regions reflect this richness in their respective solutions to building construction. Built mainly out of brick and stone, mortared and plastered by mud, the domed vernacular houses of Harran, a small town in the province of Urfa in the hot arid climate of southeastern Anatolia, are one of the best examples that deserve attention with respect to minimum energy consumption. In this study, the thermal performance of the "Harran house" as a vernacular type was analysed. For this purpose, temperatures inside and outside a Harran house complex with relative humidity variations were measured. In addition, for investigating the domed houses' thermal behaviour, temperature measurements at different surfaces and media were recorded. The solar chimney effect obtained from the dome and the importance of the thermal mass of the square base of the house were also evaluated. The study yielded results, which showed that the indoor conditions were within the limits for thermal comfort even under extreme summer conditions.