Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
2 results
Search Results
Now showing 1 - 2 of 2
Article Citation - WoS: 39Citation - Scopus: 37Flow-Through Colorimetric Assay for Detection of Nucleic Acids in Plasma(Elsevier, 2019) Ammanath, Gopal; Yeasmi, Sanjida; Srinivasulu, Yuvasri; Vats, Mukti; Cheema, Jamal Ahmed; Nabilah, Fairuz; Liedberg, Bo; Yıldız, Ümit HakanA flow-through colorimetric assay for detection of nucleic acids in plasma is reported. The proposed assay features an array of four polyvinylidene fluoride (PVDF) membranes impregnated with cationic poly (3-alkoxy-4-methylthiophene) (PT) as an optical reporter. The sensing strategy is based on monitoring the changes in optical properties of PT, upon complexation with target nucleic acids in the presence and in the absence of their corresponding complementary peptide nucleic acids (PNAs). As a proof of concept, the proposed methodology is validated using two biomarkers; lung cancer associated microRNA (mir21) and hepatitis B virus DNA (HBV-DNA). The flow-through colorimetric assay enabled detection of mir21 and HBV-DNA in plasma without requiring tedious sample pre-treatment and clean up protocols. Colorimetric responses for mir21 and HBV-DNA were obtained at nanomolar concentrations over five orders of magnitudes (from 1 nM to 10 mu M), with a limit of detection of -0.6 nM and -2 nM in DI water and plasma, respectively. A logic gate system was developed to utilize the colorimetric assay responses as inputs for discrimination of mir21 and HBV-DNA and subsequently to obtain a profile of nucleic acids in samples that exceed respective clinical threshold limits, thereby enabling rapid and point of care (POC) disease diagnosis. Furthermore, the proposed methodology can be utilized for detection of a large number of nucleic acids in plasma by extending the array of PT impregnated membranes incorporated with their corresponding complementary PNAs. (C) 2019 Elsevier B.V. All rights reserved.Article Citation - WoS: 17Citation - Scopus: 19Pixelated Colorimetric Nucleic Acid Assay(Elsevier, 2020) Aydın, Hakan Berk; Cheema, Jamal Ahmed; Arnmanath, Gopal; Toklucu, Cihan; Yücel, Müge; Özenler, Sezer; Yıldız, Ümit HakanConjugated polyelectrolytes (CPEs) have been widely used as reporters in colorimetric assays targeting nucleic acids. CPEs provide naked eye detection possibility by their superior optical properties however, as concentration of target analytes decrease, trace amounts of nucleic acid typically yield colorimetric responses that are not readily perceivable by naked eye. Herein, we report a pixelated analysis approach for correlating colorimetric responses of CPE with nucleic acid concentrations down to 1 nM, in plasma samples, utilizing a smart phone with an algorithm that can perform analytical testing and data processing. The detection strategy employed relies on conformational transitions between single stranded nucleic acid-cationic CPE duplexes and double stranded nucleic acid-CPE triplexes that yield distinct colorimetric responses for enabling naked eye detection of nucleic acids. Cationic poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1-aminium bromide] is utilized as the CPE reporter deposited on a polyvinylidene fluoride (PVDF) membrane for nucleic acid assay. A smart phone application is developed to capture and digitize the colorimetric response of the individual pixels of the digital images of CPE on the PVDF membrane, followed by an analysis using the algorithm. The proposed pixelated approach enables precise quantification of nucleic acid assay concentrations, thereby eliminating the margin of error involved in conventional methodologies adopted for interpretation of colorimetric responses, for instance, RGB analysis. The obtained results illustrate that a ubiquitous smart phone could be utilized for point of care colorimetric nucleic acids assays in complex matrices without requiring sophisticated software or instrumentation.
