Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 11
    Citation - Scopus: 18
    Forward Energy Flow, Central Charged-Particle Multiplicities, and Pseudorapidity Gaps in W and Z Boson Events From Pp Collisions at ?s = 7 Tev
    (Springer Verlag, 2012) Demir, Durmuş Ali; Karapınar, Güler
    A study of forward energy flow and central charged-particle multiplicity in events with W and Z bosons decaying into leptons is presented. The analysis uses a sample of 7 TeV pp collisions, corresponding to an integrated luminosity of 36 pb-1, recorded by the CMS experiment at the LHC. The observed forward energy depositions, their correlations, and the central charged-particle multiplicities are not well described by the available non-diffractive soft-hadron production models. A study of about 300 events with no significant energy deposited in one of the forward calorimeters, corresponding to a pseudorapidity gap of at least 1. 9 units, is also presented. An indication for a diffractive component in these events comes from the observation that the majority of the charged leptons from the W(Z) decays are found in the hemisphere opposite to the gap. When fitting the signed lepton pseudorapidity distribution of these events with predicted distributions from an admixture of diffractive (pompyt) and non-diffractive (pythia) Monte Carlo simulations, the diffractive component is determined to be (50. 0 ± 9. 3 (stat.) ± 5. 2 (syst.))%. © 2012 CERN for the benefit of the CMS collaboration.
  • Article
    Citation - WoS: 35
    Citation - Scopus: 53
    Alignment of the Cms Muon System With Cosmic-Ray and Beam-Halo Muons
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.