Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Fabrication of Bi2212 Single Crystal Bolometer for Detection of Terahertz Waves
    (Springer Verlag, 2017) Semerci, Tuğçe; Demirhan, Yasemin; Miyakawa, Nobuaki; Wang, Huabing; Özyüzer, Lütfi
    Terahertz (THz) radiation is in powerful region of electromagnetic spectrum because of prosperous application areas yet deficiency still exists about sources and detectors in despite of improvements of the research field in this range. This gap can be filled by focusing on development of THz detectors. Therefore, bolometers were preferred through many detectors due to detection sensitivity above 1 THz. In this study, Bi2Sr2CaCu2O8+δ (Bi2212) single crystals were used to fabricate THz bolometric detector. Bi2212 single crystals were transferred on sapphire substrate by cleavage process and e-beam lithography and ion beam etching were used to fabricate the microchip clean room facilities. Customdesigned cryogenic cryostat was used for a-b axis electrical and THz response measurements with liquid nitrogen cooled system. After electrical measurements, Bi2212 microchips detected the signals using Stefan-Boltzmann Lamp and response time were calculated. This study have shown with our experimental results that Bi2212 single crystals are potential candidates for THz bolometric detectors.
  • Conference Object
    Terahertz Wave Emission From Layered Superconductors: Interferometer Measurements
    (Institute of Electrical and Electronics Engineers Inc., 2011) Özyüzer, Lütfi; Türkoğlu, Fulya; Demirhan, Yasemin; Köseoğlu, Hasan; Preu, S.; Ploss, D.; Malzer, S.; Şimşek, Yılmaz; Wang, Huabing; Müller, P.
    Rectangular Bi2Sr2CaCu2O 8+δ (Bi2212) mesa structures were fabricated on as-grown Bi2212 single crystal superconductors using standard photolithography and Ar ion beam etching techniques. We have performed c-axis resistance versus temperature (R-T), current-voltage (I-V) characteristics and bolometer measurements. Furthermore, in contrast to previous studies, the emission frequency was determined using interferometer set up instead of FTIR. The interference patterns were detected outside the cryostat after traveling long way through ambient space. The emission frequency calculated by Fourier transform of interference data is consistent with Josephson frequency-voltage relation. © 2011 IEEE.