    Experimental and Numerical Investigation of Forced Convection in a Double Skin Façade by Using Nodal Network Approach for Istanbul
    (Elsevier Ltd., 2019) İnan, Tuğba; Başaran, Tahsin
    In this study, temperature distribution and heat transfer through the cavity of a double skin façade (DSF) was investigated in the laboratory environment and analyzed numerically by using nodal network approach. The verification of the nodal network method was conducted by using data from the steady-state experiments and the same method was applied for the climate of Istanbul, Turkey under unsteady outside boundary conditions. Furthermore, heat gain and loss values in DSF for January and July were calculated and compared with single skin façade (SSF) application for different directions of the façades. The results were given for a day and a working time period of the office buildings by using monthly average daily climate data. Distinction working hours were more convenient to investigate the energy performance of DSF because of solar radiation effect. Using DSF in all directions, the cooling loads decreased up to 26% comparing to the SSF. DSF system was disadvantageous comparing to the SSF for January. However, it was shown that the heated air in the cavity could be used for preheating process of air in a HVAC system for winter period.
  • Article
    Citation - WoS: 18
    Citation - Scopus: 21
    Experimental and Numerical Investigation of Forced Convection in a Double Skin Façade
    (MDPI Multidisciplinary Digital Publishing Institute, 2017) İnan, Tuğba; Başaran, Tahsin; Erek, Aytunç
    Flow and heat transfer of the air cavity between two glass façades designed in the box window type of double skin façade (DSF) was evaluated in a test room which was set up for measurements in the laboratory environment and analyzed under different working conditions by using a computational fluid dynamics tool. Using data from the experimental studies, the verification of the numerical studies was conducted and the air flow and heat transfer in the cavity between the two glass façades were examined numerically in detail. The depth to height of the cavity, the aspect ratio, was changed between 0.10 and 0.16, and was studied for three different flow velocities. Reynolds and average Nusselt numbers ranging from 28,000 to 56,500 and 134 to 272, respectively, were calculated and a non-dimensional correlation between Reynolds and Nusselt numbers was constructed to evaluate the heat transfer from the cavity (except inlet and outlet sections) air to the inside environment and it could be used the box window type of DSF applications having relatively short cavities.
  • Article
    Citation - WoS: 32
    Citation - Scopus: 38
    Fully Developed Forced Convection in a Parallel Plate Channel With a Centered Porous Layer
    (Springer Verlag, 2012) Çekmer, Özgür; Mobedi, Moghtada; Özerdem, Barış; Pop, Ioan
    In this study, fully developed heat and fluid flow in a parallel plate channel partially filled with porous layer is analyzed both analytically and numerically. The porous layer is located at the center of the channel and uniform heat flux is applied at the walls. The heat and fluid flow equations for clear fluid and porous regions are separately solved. Continues shear stress and heat flux conditions at the interface are used to determine the interface velocity and temperature. The velocity and temperature profiles in the channel for different values of Darcy number, thermal conductivity ratio, and porous layer thickness are plotted and discussed. The values of Nusselt number and friction factor of a fully clear fluid channel (Nu cl = 4. 12 and fRe cl = 24) are used to define heat transfer increment ratio (ε th = Nu p/Nu cl)and pressure drop increment ratio (ε p = f Re p/f Re cl) and observe the effects of an inserted porous layer on the increase of heat transfer and pressure drop. The heat transfer and pressure drop increment ratios are used to define an overall performance (ε = ε th/ε p) to evaluate overall benefits of an inserted porous layer in a parallel plate channel. The obtained results showed that for a partially porous filled channel, the value of ε is highly influenced from Darcy number, but it is not affected from thermal conductivity ratio (k r) when k r > 2. For a fully porous material filled channel, the value of ε is considerably affected from thermal conductivity ratio as the porous medium is in contact with the channel walls.