Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
2 results
Search Results
Now showing 1 - 2 of 2
Article Citation - WoS: 14Citation - Scopus: 14Thermal Simulation of Retrofits To Existing Mass Housing in Turkey for Energy Efficiency(Sila Science, 2011) Yıldız, Yusuf; Durmuş Arsan, ZeynepEnergy consumption in the existing residential building stock in Turkey is currently excessive. Mass housing, comprising a major portion of the officially-registered residential stock, carries enormous potential for energy savings even in the short run. This paper describes a case study in a mass housing area in Izmir, Turkey, in order to demonstrate the possibility of significant energy savings by implementing case-specific energy-efficient retrofitting scenarios and relating them with the payback periods. Building energy analysis software was used to examine thirteen scenarios consisting of various combinations of four main retrofitting options: addition of extra insulation for building envelope, replacement of existing glazing, regulation of air infiltration rate and indoor set point temperature. These scenarios revealed that annual energy savings of up to 62% are achievable and that the customer payback period for the best retrofitting scenario is 34 years.Article Citation - WoS: 7Citation - Scopus: 9Simulation-Based Retrofitting of an Educational Building in Terms of Optimum Shading Device and Energy Efficient Artificial Lighting Criteria(Znack Publishing House, 2016) Bayram, Göze; Kazanasmaz, Zehra TuğçeThe high level of daylight performance is crucial to increase academic and work performance of students and staff in educational buildings which are mostly used during the daytime. New design solutions have potential to reach optimum lighting conditions and minimum energy consumption. So, the purpose of this study is to evaluate and propose an energy efficient lighting design for an educational building. The aim is to find the optimum type of shading device with appropriate slat angles, transmittance of glazing, and the luminaire type/layout as well. Utilizing DIALux simulations, scenarios for combinations of these inputs are tested for classrooms, offices and a laboratory, which are non-identical due to their orientation, size, window characterization and facade organization. The procedure covers all significant days (winter/ summer solstice and equinoxes) during one year. Such an integrated approach would be proposed for lighting design and retrofit applications. © 2016, LLC Editorial of Journal “Light Technik”. All rights reserved.