Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
3 results
Search Results
Now showing 1 - 3 of 3
Article Citation - WoS: 4Citation - Scopus: 4Estimation of Heat Production Rate Using Thermal Data During Exercise in Indoor Environments: a Study of Heat Storage Rate in Male Athletes(Springer, 2024) Balci, Gorkem Aybars; Avci, Ali Berkay; Colakoglu, Muzaffer; Basaran, Tahsin; Balcı, Görkem Aybars; Avcı, Ali Berkay; Çolakoğlu, Muzaffer; Başaran, TahsinThe increasing preference for indoor exercise spaces highlights the relationship between indoor thermal environments and physiological responses, particularly concerning thermal comfort during physical activity. Determining the metabolic heat production rate during exercise is essential for optimizing the thermal comfort, well-being, and performance of individuals engaged in physical activities. This value can be determined during the activity using several methods, including direct calorimetry measurement, indirect calorimetry that uses analysis of respiratory gases, or approximations using collected data such as speed, body mass, and heart rate. The study aimed to calculate the metabolic heat production rate by infrared thermal evaluation (ITE) based on the body's thermal balance approach and compare it with the values determined by indirect calorimetry (IC). Fourteen participants volunteered for the study, using a cycling ergometer in a controlled climatic chamber. After the familiarization sessions, maximal O-2 intake levels (VO2max) were determined through maximal graded exercise tests. Subsequently, constant work rate exercise tests were performed at 60% of VO2max for 20 min. The metabolic heat production rates were calculated by IC and ITE for each athlete individually. Respiratory gases were used to determine IC, while body skin and core temperatures, along with physical environmental data, were applied to calculate ITE using the human body thermal balance approximation of ASHRAE. According to the results, heat storage rates were misleading among the body's heat transfer modes, particularly during the first 8 min of the exercise. ITE showed a moderate level of correlation with IC (r: 0.03-0.86) with a higher level of dispersion relative to the mean (CV%: 12-84%). Therefore, a new equation (ITEnew) for the heat storage rates was proposed using the experimental data from this study. The results showed that ITEnew provided more precise estimations for the entire exercise period (p > 0.05). Correlations between ITEnew and IC values were consistently strong throughout the exercise period (r: 0.62-0.85). It can be suggested that ITEnew values can predict IC during the constant work rate steady-state exercise.Article Citation - WoS: 1Citation - Scopus: 1EXPERIMENTAL AND ANALYTICAL EXAMINATION OF THE EFFECT OF DOUBLE SKIN FAÇADE SYSTEM ON BUILDING THERMAL PERFORMANCE;(Turk Isi Bilimi ve Teknigi Dernegi, 2021) Hülagü,S.; Göksal Özbalta,T.; Başaran,T.In this study, heat transfer in conventional single skin façade and double skin façade system was studied experimentally and numerically by using one dimensional time dependent approach and the effects of the façade systems on building energy performance especially heating energy was investigated. In this context, a mathematical model considering user behavior and window aluminum frame element effect was build by zonal analysis method to calculate the heat transfer in single and box type closed cavity double skin façade systems, and build model was experimentally verified. Experimental study was conducted in office spaces having single and double skin façade systems in Ege University, Civil Engineering Building’s south façade in January 2017. Next, verified model was used to study the heat transfer in the façade systems for İzmir’s climatic condition by using monthly average daily data. The change in thermal performance of single and double skin façade systems due to the climatic condition during a year was investigated by using the 10 year average climate data of İzmir (Mediterranean climate). It was found that double skin façade system acts as an insulator preventing extreme indoor temperature values, thus contributing to the indoor comfort level against changing outdoor conditions. ©2021 TIBTD Printed in Turkey.Article Citation - WoS: 14Citation - Scopus: 17Experimental Investigation on Heat Transfer and Air Flow Behavior of Latent Heat Storage Unit in a Facade Integrated Ventilation System(Elsevier Ltd, 2021) Pekdogan,T.; Tokuç,A.; Ezan,M.A.; Başaran,T.All-air central HVAC systems are widely applied to provide fresh and conditioned air, which is very important for users to lead healthy and productive lives. Decentralized systems are another mechanical solution to ensure indoor air quality and thermal comfort with a heat recovery ventilation system integrated into the building wall. These commercially available systems store sensible energy in the heat exchanger. In this study, an experimental real-size staggered tube bundled prototype with phase change material (PCM), which stores latent thermal energy, was proposed/designed and full-scale experiments were carried out in laboratory conditions. The experimental setup includes two spaces that simulate indoor and outdoor conditions that are separated by an insulated aerated concrete wall. In the prototype, two ducts embedded in the wall contain staggered tube bundles filled with PCM, which are positioned perpendicular to the airflow to recover heat for supply and exhaust ventilation modes. The thermal performance of this prototype is investigated for different operating times, namely, 15, 20, and 30 min. The average air energy change of the latent heat recovery ventilation system values is between 20 and 35 kJ approximately for the operating times. The supply mode efficiency result is an average of 50% and exhaust mode efficiency is 25%. © 2021 Elsevier Ltd
