Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
8 results
Search Results
Now showing 1 - 8 of 8
Article Citation - WoS: 5Citation - Scopus: 5Comparison of Advanced Daylighting Systems To Improve Illuminance and Uniformity Through Simulation Modelling(Znack Publishing House, 2014) Kazanasmaz, Zehra Tuğçe; Fırat Örs, PelinDeficiencies in daylighting performance (illuminance and uniformity) of educational facilities may cause health problems, work performance loss and excessive energy consumption. The varying nature of daylight in daily and yearly basis is a strong challenge on that matter. Advanced daylighting systems have been developed to overcome this challenge. Improving the daylighting performance of existing buildings is another difficulty in daylighting design. Daylighting design needs should be carefully considered at the initial design stages of the buildings. So, the aim of this study was to improve the illuminance and uniformity in four selected architectural design studios in Izmir. Measurements of daylight illuminance were conducted in May and June 2012. Simulation models were built in Ecotect/Radiance. To reach the best daylighting performance, simulations were carried out by Desktop Radiance with applying laser cut panels, prismatic panels and light shelves. It is considered that retrofitting efforts after the construction would be inadequate regarding daylighting, unless complying with the standards during the design process.Article Citation - WoS: 3Citation - Scopus: 2User Lighting Preferences Based on Navigation and Space Quality in Virtual Exhibition Environments(Znack Publishing House, 2020) Çevik, Aslıhan; Kazanasmaz, Zehra Tuğçe; Duran, Hasan EnginJust as any other interior environment, lighting of exhibition spaces must be examined to enhance its visual quality and comfort. In this study, user behaviour, perception and impressions are analyzed for more comprehensive understanding by including subjective reasoning. Due to the chaotic progress and contradictory choices in exhibition lighting, daylight is mostly avoided while the role of users and relation between quantitative and qualitative parameters are often neglected. A series of sample exhibition spaces illuminated either artificially or by daylight are modelled virtually in Lumion software to be evaluated in a three-step questionnaire. A total of 90 participants are selected from three different professions (architects, visitors, artists), their reaction like movement, preference and impressions are gathered via questionnaire while moving through the model. The study aims to find out the role of lighting type in exhibition navigation and its relation with non-lighting parameters using statistical analysis methods. Results show that natural light is preferred more in sculpture exhibition while artificial light is preferred in painting exhibition. Movement towards daylight increases in transition areas and towards the end of the exhibition. A significant difference in navigation choices are found between professions, architects preferred to move towards more natural light while artists preferred artificial light.Article Citation - WoS: 2Citation - Scopus: 2An Empirical Validation of Estimation Model (optimlum) for Energy Efficient Luminaire Layout Design in Offices(Znack Publishing House, 2020) Uygun, İlknur Erlalelitepe; Kazanasmaz, Zehra Tuğçe; Kale, SerdarThis study performed with the purpose of constructing and validating a model named OptimLUM ( Optimizing Luminaire Layouts) to estimate the most accurate location, number and type of artificial light sources according to average illuminance and maximum uniformity in an office. OptimLUM is appling through Excel Spreadsheet to develop the model and uses Evolver, which is basing on genetic algorithm to implement optimization routine. To validate the reliability of the proposed model, luminaire layout scenairos generated for two types of luminaires after taking illuminance measurements in an actual office. OptimLUM illuminance values were comparing statistically with measurement and DIALux results to test the applicability of the model. The model performance is highly accurate in determining luminaire positions: coefficient of determination R-2 and coefficient of variation CV were equal to (86-99)% and to (0.04-0.12) respectively, and for all scenarios. Its outputs are closer to the actual measurements when compared with DIALux outputs.Article Citation - WoS: 7Citation - Scopus: 7Applicability of a Prismatic Panel To Optimize Window Size and Depth of a South-Facing Room for a Better Daylight Performance(Znack Publishing House, 2020) Köse, Büşra; Kazanasmaz, Zehra TuğçeThis study examines the performance of attached prismatic panels, which have shading capability, in a side-lit deep plan room to find out the least possible WWR value in relation to room depth satisfying the required daylight availability. The methodology is based on simulating a base model in Relux and testing it with alternative models composed of incrementally defined WWR and room depth values. In accordance with minimum IES requirements, the most satisfying sDA value was found to be 48.54 % in a room of 12 m depth with 67 % WWR. An sDA of 51.59 % and 59.26 % was achieved in a room of 9m depth with 43 % WWR and 6m depth with 30 % WWR, respectively. The least ASE values were obtained with the least WWR alternative of 30 % in all room depths. This study presents a new approach with the consideration of innovative daylight redirecting systems to propose revisions for the requirements mentioned in standards about daylight in buildings but based on conventional fenestration systems. © 2020, LLC Editorial of Journal ""Light Technik"". All rights reserved.Article Citation - WoS: 4Citation - Scopus: 5Illuminance and Luminance Based Ratios in the Scope of Performance Testing of a Light Shelf-Reflective Louver System in a Library Reading Room(Znack Publishing House, 2019) Öner, Merve; Kazanasmaz, Zehra TuğçeUncontrolled daylight brings visual and thermal problems that may result in negative interactions with user comfort, productivity, well-being, and human health. Library spaces, in which reading, writing, and computer task activities are performed, need to be well designed in terms of daylight performance to enhance user satisfaction. The focus of this study is to make a performance test of a light shelf-reflective louver system to improve the visual performance conditions of a library reading room. First, the instrumental monitoring of existing daylighting conditions was performed. Second, Relux model was prepared to evaluate luminance patterns and illuminance distribution. Third, a new light shelf-reflective louver system was proposed based on the insufficiencies of the simulation results. The performance of the new system was found highly satisfactory based on the findings of enhanced luminance patterns and uniformity ratios especially at the points near the windows.Article Citation - WoS: 1Citation - Scopus: 6Examining Occupancy and Architectural Aspects Affecting Manual Lighting Control Behaviour in Offices Based on a User Survey(Znack Publishing House, 2018) Cilasun Kunduracı, Arzu; Kazanasmaz, Zehra Tuğçe; Hordijk, TruusFurther understanding the building occupants’ needs and behaviors can reduce lighting energy consumption. This research explores how the occupancy and interior architectural aspects become effective in manual lighting control in offices. It involves a multiple sectioned questionnaire focusing on the possible architectural factors such as the desk position, the surface colours, the distance to window, the distance between desk and lighting switch, and inquiring participants’ manual lighting control behaviour through the photographs of modified interior layouts, surface colours and time intervals. Statistical methods are used to determine the significant aspects, which may reduce the use of lighting control. Interior layout, distance to window, time of the day, and number of occupants in the offices are the most significant contributions to the manual lighting control behaviour. To pay attention in these contributions, it would be possible to reduce the use of electricity for lighting while user satisfaction increases.Article Citation - WoS: 7Citation - Scopus: 8Performance Indices of Soft Computing Models To Predict the Heat Load of Buildings in Terms of Architectural Indicators(Yıldız Teknik Üniversitesi, 2017) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, GüldenThis study estimates the heat load of buildings in Izmir/Turkey by three soft computing (SC) methods; Artificial Neural Networks (ANNs), Fuzzy Logic (FL) and Adaptive Neuro-based Fuzzy Inference System (ANFIS) and compares their prediction indices. Obtaining knowledge about what the heat load of buildings would be in architectural design stage is necessary to forecast the building performance and take precautions against any possible failure. The best accuracy and prediction power of novel soft computing techniques would assist the practical way of this process. For this purpose, four inputs, namely, wall overall heat transfer coefficient, building area/ volume ratio, total external surface area and total window area/total external surface area ratio were employed in each model of this study. The predicted heat load is evaluated comparatively using simulation outputs. The ANN model estimated the heat load of the case apartments with a rate of 97.7% and the MAPE of 5.06%; while these ratios are 98.6% and 3.56% in Mamdani fuzzy inference systems (FL); 99.0% and 2.43% in ANFIS. When these values were compared, it was found that the ANFIS model has become the best learning technique among the others and can be applicable in building energy performance studies.Article Citation - WoS: 7Citation - Scopus: 9Simulation-Based Retrofitting of an Educational Building in Terms of Optimum Shading Device and Energy Efficient Artificial Lighting Criteria(Znack Publishing House, 2016) Bayram, Göze; Kazanasmaz, Zehra TuğçeThe high level of daylight performance is crucial to increase academic and work performance of students and staff in educational buildings which are mostly used during the daytime. New design solutions have potential to reach optimum lighting conditions and minimum energy consumption. So, the purpose of this study is to evaluate and propose an energy efficient lighting design for an educational building. The aim is to find the optimum type of shading device with appropriate slat angles, transmittance of glazing, and the luminaire type/layout as well. Utilizing DIALux simulations, scenarios for combinations of these inputs are tested for classrooms, offices and a laboratory, which are non-identical due to their orientation, size, window characterization and facade organization. The procedure covers all significant days (winter/ summer solstice and equinoxes) during one year. Such an integrated approach would be proposed for lighting design and retrofit applications. © 2016, LLC Editorial of Journal “Light Technik”. All rights reserved.
