Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
3 results
Search Results
Now showing 1 - 3 of 3
Article Citation - WoS: 19Citation - Scopus: 20Numerical Analysis of a Near-Room Magnetic Cooling System(Elsevier Ltd., 2017) Ezan, Mehmet Akif; Ekren, Orhan; Metin, Çağrı; Yılancı, Ahmet; Bıyık, Emrah; Kara, Salih MuratIn this study, for a near-room-temperature magnetic cooling system, a decoupled multi-physics numerical approach (Magnetism, Fluid Flow, and Heat Transfer) is developed using a commercial CFD solver, ANSYS-FLUENT, as a design tool. User defined functions are incorporated into the software in order to take into account the magnetocaloric effect. Magnetic flux density is assumed to be linear during the magnetization and demagnetization processes. Furthermore, the minimum and maximum magnetic flux densities (Bmin and Bmax) are defined as 0.27 and 0.98, respectively. Two different sets of analyses are conducted by assuming an insulated cold heat exchanger (CHEX) and by defining an artificial cooling load in the CHEX. As a validation case, experimental work from the literature is reproduced numerically, and the results show that the current methodology is fairly accurate. Moreover, parametric analyses are conducted to investigate the effect of the velocity of heat transfer fluid (HTF) and types of HTF on the performance of the magnetic cooling system. Also, the performance metrics of the magnetic cooling system are investigated with regards to the temperature span of the magnetic cooling unit, and the cooling load. It is concluded that reducing the cycle duration ensures reaching lower temperature values. Similarly, reducing the velocity of the HTF allows reducing the outlet temperature of the HTF. In the current system, the highest temperature spans are obtained numerically as around 6 K, 5.2 K and 4.1 K for the cycle durations of 4.2 s, 6.2 s and 8.2 s, respectively.Article Citation - WoS: 12Citation - Scopus: 16Numerical Optimization of a Fin-Tube Gas To Liquid Heat Exchanger(Elsevier Ltd., 2012) Bilir, Levent; İlken, Zafer; Erek, AytunçThe influence of plate fin, fin tube and protrusion parameters on heat transfer and pressure drop characteristics of a finned tube gas to liquid heat exchanger is examined in this study. The optimization of plate fin, fin tube and protrusion dimensions as well as protrusion locations on plate fin surface is performed numerically using a computational fluid dynamics (CFD) program named "Fluent". The dimensions of the plate fin of a commercially available combi boiler apparatus heat exchanger are taken as basic dimensions. As the first step, the best plate fin and fin tube geometry is determined. Secondly, the best dimensions for three different protrusions (balcony, winglet and imprint) and their most suitable locations on the plate fin surface are found. Finally, the cumulative effects of several combinations of these three protrusions on the plate fin surface are analyzed. The placement combinations of protrusions are decided according to the results obtained for the individual effect of each protrusion. The fin named as I5B2W3 is found to be the most efficient fin among the investigated cases. A comparison with a numerical and computational study is also performed to validate the numerical results of the present study. © 2011 Elsevier Masson SAS. All rights reserved.Article Citation - WoS: 101Citation - Scopus: 132Effect of Geometrical Parameters on Heat Transfer and Pressure Drop Characteristics of Plate Fin and Tube Heat Exchangers(Elsevier Ltd., 2005) Erek, Aytunç; Özerdem, Barış; Bilir, Levent; İlken, ZaferIn this study, the influences of the changes in fin geometry on heat transfer and pressure drop of a plate fin and tube heat exchanger are investigated, numerically. A computational fluid dynamics (CFD) program called Fluent is used in the analysis. The segment of one tenth of fin is used in the modeling, due to symmetrical condition. The results of heat transfer, static, and total pressure drop values of ten different fins are tabulated and the normalized values of them are, also, given for the comparison of the models. The distance between fins is found to have a considerable effect on pressure drop. It is observed that placing the fin tube at downstream region affects heat transfer positively. Another important result of the study is that increasing ellipticity of the fin tube increases the heat transfer while it, also, results in an important reduction in pressure drop.
