Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
4 results
Search Results
Now showing 1 - 4 of 4
Article Amino Acid Selection Altered Silver Nanoparticles Morphology and Formation of Silver Oxide Layers(Multidisciplinary Digital Publishing Institute (MDPI), 2025) Bolat, Ş.; Sancak, Z.; Gumus, A.; Yazgan, I.Amino acids are not just monomers of proteins, but they can also carry biological functions. L-cysteine (Cys), L-proline (Pro), L-asparagine (Asn), and L-glutamic acid (Glu) were used to evaluate how different amino acid chemistries alter the morphology and size of the silver nanoparticles (AgNPs) synthesized in the presence of two carbohydrate ligands, which were lactose methoxyaniline (LMA) and galactose 5-aminosalicylic acid (G5AS). UV–vis, infrared (IR), High-Resolution Transmission Electron Microscopy (HR-TEM) and X-ray diffraction (XRD) characterizations revealed that the effect of amino acids on the characteristics of the AgNPs showed dependence on the carbohydrate ligand chemistry. In the case of LMA, AgNPs shifted from aggregates to anisotropic nanoparticles, larger aggregates, and a mixture of anisotropic and 1D nanoparticles in the presence of Cys, Glu, Asn and Pro amino acids, respectively. In contrast to this, the introduction of Cys and Asn caused the formation of cluster-like AgNPs and larger rounded nanoparticles, while G5AS-synthesized AgNPs were multigonal 0D particles. Moreover, Glu and Pro contributed the resistance of silver oxide formation on the particles. Antibacterial characterization showed that LMA_Glu_AgNPs were the most effective ones, while LMA_Cys_AgNPs and G5AS_Cys_AgNPs, which were the smallest AgNPs, did not show any significant antibacterial activity. © 2025 Elsevier B.V., All rights reserved.Article Citation - Scopus: 1Assessing the Density of Wood in Heritage Buildings’ Elements Through Expedited Semi-Destructive Techniques(Multidisciplinary Digital Publishing Institute (MDPI), 2025) Henriques, Dulce F.; Sen, Ali Umut; Gomes, Maria da GloriaFeatured Application The research presented and justified in this text aims to provide agents involved in the conservation and refurbishment of old timber elements in buildings with a correlation table for interpreting the readings obtained with penetration resistance testing equipment.Abstract Historically, wood has been among the main materials used in heritage buildings. However, the species and mechanical properties of these elements are often unknown. This uncertainty complicates safety assessment calculations, aggravated by the natural variability of the wood properties. The aim of this work is to assess the density of wooden elements in service using semi-destructive techniques that retain the integrity of structural elements. This research had two phases. First, penetration resistance tests were carried out on laboratory scale on Pinus sylvestris L. wood samples taken from 18th, 19th, and 20th century heritage buildings in Lisbon, Portugal. Later, a field study was carried out on wooden elements from the same buildings, involving needle penetration, core drilling, and moisture content determination tests. The laboratory test results showed a strong correlation between the needle penetration depth and wood density, with an R2 value of 0.76. The results of the field study indicated that the density estimated by the needle penetration test correlated effectively with the measured density of extracted cores after moisture correction, with an R2 of 0.99. In conclusion, the experimental results confirm that penetration resistance and moisture tests are reliable and practical for estimating wood density under in-service conditions.Article Citation - WoS: 5Citation - Scopus: 6Effect of Graphene Nanoplatelet Content on Mechanical and Elevated-Temperature Tribological Performance of Self-Lubricating Ze10 Magnesium Alloy Nanocomposites(Multidisciplinary Digital Publishing Institute (MDPI), 2024) Kandemir,S.; Yöyler,S.; Kumar,R.; Antonov,M.; Dieringa,H.Magnesium (Mg) and graphene in alloy formulations are of paramount importance for lightweight engineering applications. In the present study, ZE10 Mg-alloy-based nanocomposites reinforced with graphene nanoplatelets (GNPs) having a thickness of 10–20 nm were fabricated via ultrasound-assisted stir casting. The effect of GNP contents (0.25, 0.5, and 1.0 wt.%) on the microstructure, Vickers hardness, and tensile properties of nanocomposites was investigated. Further, tribological studies were performed under a ball-on-disc sliding wear configuration against a bearing ball counterbody, at room and elevated temperatures of 100 °C and 200 °C, to comprehend temperature-induced wear mechanisms and friction evolution. It was revealed that the GNP addition resulted in grain coarsening and increased porosity rate of the Mg alloy. While the composites exhibited improved hardness by 20–35% at room temperature and 100 °C, a minor change was observed in their hardness and tensile yield strength values at 200 °C with respect to the GNP-free alloy. A notable improvement in lowering and stabilizing friction (coefficient of friction at 200 °C~0.25) and wear values was seen for the self-lubricating GNP-added composites at all sliding temperatures. The worn surface morphology indicated a simultaneous occurrence of abrasive and adhesive wear mode in all samples at room temperature and 100 °C, while delamination and smearing along with debris compaction (tribolayer protection) were the dominant mechanisms of wear at 200 °C. Inclusively, the results advocate steady frictional conditions, improved wear resistance, and favorable wear-protective mechanisms for the Mg alloy–GNP nanocomposites at room and elevated temperatures. © 2024 by the authors.Article Citation - WoS: 3Citation - Scopus: 3Assessment of Mutual Variation of Near-Surface Air Temperature, Land Surface Temperature and Driving Urban Parameters at Urban Microscale(Multidisciplinary Digital Publishing Institute (MDPI), 2023) Gerçek,D.; Güven,İ.T.The Urban Heat Island (UHI) effect is of critical concern for cities’ adaptation to climate change. The UHI effect shows substantial intra-urban variation at the city microscale, causing disparities in thermal comfort and energy consumption. Therefore, air temperature assessment should be prioritized for effective heat mitigation and climate adaptation. However, meteorological stations’ spatial distribution is far from meeting the scale that the UHI and its driving parameters operate. This limitation hampers demonstrating the intra-city variability of UHI and its origin of sources; for example, most studies employ Land Surface Temperature (LST), usually without demonstrating the relationship between UHI and LST. The current body of knowledge on urban climate implies a much better understanding and more detailed information on the spatial pattern of UHI and the driving factors to provide decision-makers with tools to develop effective UHI mitigation and adaptation strategies. In an attempt to address the adequacy of the use of LST and UPs in describing the intra-city variability of UHI, this study investigates the relationship between LST daytime and nighttime, and air temperature (Ta) daytime and nighttime, and driving urban parameters (UPs) of UHI together. Although it is well recognized that the intensity of the UHI is characterized by Ta, particularly at night, so-called nocturnal UHI, the use of remotely sensed LST is common, owing to the lack of spatially detailed Ta data in cities. Our findings showed that nocturnal UHI is weakly correlated with nighttime LST with a Pearson correlation (r) of 0.335 at p > 0.05 and that it is not correlated with daytime LST for the case study, highlighting the need for Ta observations for representing the intra-urban variation of nocturnal UHI. Among UPs, Sky View Factor (SVF), Building Volume Density (BVD), and Road Network Density (RND) explained 69% of the variability of Ta nighttime that characterizes nocturnal UHI. Therefore, UPs that performed well in estimating nocturnal UHI may be used in the absence of densely distributed Ta measurements. In a further investigation of the urban cooling phenomenon based on UHI diurnal changes, a particular region with high nighttime temperatures spoiled the Ta daytime and nighttime coherence. This region is characterized by high Mean Building Height (MBH), BFD, and BVD that re-emits heat, low SVF that prevents urban cooling, and high RND that releases extra heat at night. These particular UPs can be of prior interest for urban cooling. The present study, exploring the relationships of LST and Ta in a diurnal context, offers a further understanding of the preference of LST, Ta, or UPs to characterize UHI. Ta, in relation to major causative factors (UPs), provides insights into addressing the localities most vulnerable to the UHI effect and possible strategies targeting heat mitigation for sustainability and climate change resilience. © 2023 by the authors.
