Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 10 of 26
  • Article
    Citation - WoS: 9
    Citation - Scopus: 78
    Reconstruction and Identification of ? Lepton Decays To Hadrons and ?? at Cms
    (IOP Publishing Ltd., 2016) CMS Collaboration; Karapınar, Güler
    This paper describes the algorithms used by the CMS experiment to reconstruct and identify τ → hadrons + νtau; decays during Run 1 of the LHC. The performance of the algorithms is studied in proton-proton collisions recorded at a centre-of-mass energy of 8 TeV, corresponding to an integrated luminosity of 19.7 fb-1. The algorithms achieve an identification efficiency of 50-60%, with misidentification rates for quark and gluon jets, electrons, and muons between per mille and per cent levels.
  • Article
    Citation - WoS: 208
    Citation - Scopus: 186
    Performance of Photon Reconstruction and Identification With the Cms Detector in Proton-Proton Collisions at ?s = 8 Tev
    (IOP Publishing Ltd., 2015) CMS Collaboration; Karapınar, Güler
    A description is provided of the performance of the CMS detector for photon reconstruction and identification in proton-proton collisions at a centre-of-mass energy of 8 TeV at the CERN LHC. Details are given on the reconstruction of photons from energy deposits in the electromagnetic calorimeter (ECAL) and the extraction of photon energy estimates. The reconstruction of electron tracks from photons that convert to electrons in the CMS tracker is also described, as is the optimization of the photon energy reconstruction and its accurate modelling in simulation, in the analysis of the Higgs boson decay into two photons. In the barrel section of the ECAL, an energy resolution of about 1% is achieved for unconverted or late-converting photons from Hγγ decays. Different photon identification methods are discussed and their corresponding selection efficiencies in data are compared with those found in simulated events. © CERN 2015 for the benefit of the CMS collaboration.
  • Article
    Citation - WoS: 519
    Citation - Scopus: 401
    Determination of Jet Energy Calibration and Transverse Momentum Resolution in Cms
    (IOP Publishing Ltd., 2011) Karapınar, Güler; Demir, Durmuş Ali
    Measurements of the jet energy calibration and transverse momentum resolution in CMS are presented, performed with a data sample collected in proton-proton collisions at a centre-of-mass energy of 7TeV, corresponding to an integrated luminosity of 36pb-1. The transverse momentum balance in dijet and γ/Z+jets events is used to measure the jet energy response in the CMS detector, as well as the transverse momentum resolution. The results are presented for three different methods to reconstruct jets: a calorimeter-based approach, the "Jet-Plus-Track" approach, which improves the measurement of calorimeter jets by exploiting the associated tracks, and the "Particle Flow" approach, which attempts to reconstruct individually each particle in the event, prior to the jet clustering, based on information from all relevant subdetectors.
  • Article
    Citation - WoS: 44
    Citation - Scopus: 88
    Performance and Operation of the Cms Electromagnetic Calorimeter
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 34
    Citation - Scopus: 42
    Performance of Cms Hadron Calorimeter Timing and Synchronization Using Test Beam, Cosmic Ray, and Lhc Beam Data
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 33
    Citation - Scopus: 44
    CMS Data Processing Workflows During an Extended Cosmic Ray Run
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 33
    Citation - Scopus: 44
    Aligning the Cms Muon Chambers With the Muon Alignment System During an Extended Cosmic Ray Run
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 33
    Citation - Scopus: 44
    Measurement of the Muon Stopping Power in Lead Tungstate
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 35
    Citation - Scopus: 43
    Commissioning of the Cms High-Level Trigger With Cosmic Rays
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    The CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.
  • Article
    Citation - WoS: 41
    Citation - Scopus: 41
    Calibration of the Cms Drift Tube Chambers and Measurement of the Drift Velocity With Cosmic Rays
    (IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, Güler
    This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the calibration is to determine, for each drift cell, the minimum time delay for signals relative to the trigger, accounting for the drift velocity within the cell. The accuracy of the calibration procedure is influenced by the random arrival time of the cosmic muons relative to the LHC clock cycle. A more refined analysis of the drift velocity was performed during the offline reconstruction phase, which takes into account this feature of cosmic ray events. © 2010 IOP Publishing Ltd and SISSA.