Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - Scopus: 8
    Optimal Design of the Type Iii Hydrogen Storage Tank for Different Carbon/Epoxy Materials by Modified Differential Evolution Method
    (MIM RESEARCH GROUP, 2019) Ayakdaş,O.; Aydın,L.; Savran,M.; Küçükdoğan,N.; Öztürk,S.
    In this study, the main objective is to minimize the failure index of a cylindrical laminated composite hydrogen storage tank under internal pressure. The first step is to obtain the distribution of stress components based on Classical Laminated Plate Theory (CLPT). The second is to evaluate the burst pressure of the tank according to three different first ply failure criteria and then to compare the results with the experimental and numerical ones from literature. In the final part of the study, the best possible combination of winding angles, stacking sequences and thicknesses of laminates satisfying minimum possible stress concentration will be obtained for different Carbon/Epoxy materials by Differential Evolution Method. The stress components and, the burst pressures reached according to Hashin-Rotem, Maximum Stress, and Tsai-Wu first-ply failure criteria, have been complied with experimental and numerical results in the literature for Type III pressure vessels. Manufacturable Type-III tank designs have been proposed satisfying the 35 MPa burst pressure for different Carbon/Epoxy materials. © 2019 MIM Research Group. All rights reserved.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 14
    Development of Tissue-Engineered Vascular Grafts From Decellularized Parsley Stems
    (Royal Society of Chemistry, 2023) Çevik, Merve; Dikici, Serkan
    Cardiovascular diseases are mostly associated with narrowing or blockage of blood vessels, and it is the most common cause of death worldwide. The use of vascular grafts is a promising approach to bypass or replace the blocked vessels for long-term treatment. Although autologous arteries or veins are the most preferred tissue sources for vascular bypass, the limited presence and poor quality of autologous vessels necessitate seeking alternative biomaterials. Recently, synthetic grafts have gained attention as an alternative to autologous grafts. However, the high failure rate of synthetic grafts has been reported primarily due to thrombosis, atherosclerosis, intimal hyperplasia, or infection. Thrombosis, the main reason for failure upon implantation, is associated with damage or absence of endothelial cell lining in the vascular graft's luminal surface. To overcome this, tissue-engineered vascular grafts (TEVGs) have come into prominence. Alongside the well-established scaffold manufacturing techniques, decellularized plant-based constructs have recently gained significant importance and are an emerging field in tissue engineering and regenerative medicine. Accordingly, in this study, we demonstrated the fabrication of tubular scaffolds from decellularized parsley stems and recellularized them with human endothelial cells to be used as a potential TEVG. Our results suggested that the native plant DNA was successfully removed, and soft tubular biomaterials were successfully manufactured via the chemical decellularization of the parsley stems. The decellularized parsley stems showed suitable mechanical and biological properties to be used as a TEVG material, and they provided a suitable environment for the culture of human endothelial cells to attach and create a pseudo endothelium prior to implantation. This study is the first one to demonstrate the potential of the parsley stems to be used as a potential TEVG biomaterial. © 2024 The Royal Society of Chemistry.
  • Article
    Citation - WoS: 12
    Citation - Scopus: 20
    Experimental Investigations on the Ballistic Impact Performances of Cold Rolled Sheet Metals
    (Elsevier Ltd., 2011) Durmuş, Ali; Güden, Mustafa; Gülçimen, Betül; Ülkü, Sedat; Musa, Eldar
    This study focuses on the ballistic performances of 1 and 2 mm-thick and 2 × 1 mm-thick cold rolled sheet metal plates against 9 mm standard NATO projectile. The velocity of the projectile before and after perforation, the diameter of the front face deformation, the depth of the crater and the diameter of the hole were measured. The fracture surfaces of the plates near the ballistic limit were also microscopically analyzed. The highest ballistic limit was found in 2 mm-thick plate (332 m s−1) and the lowest in 1 mm-thick plate (97 m s−1). While, the ballistic limit of 2 × 1 mm-thick plate decreased to 306 m s−1. Typical failure mechanism of the projectile was the flattening and mushrooming at relatively low velocities and the separation from the jacket at relatively high velocities. In accord with the ballistic limits, 2 mm-thick target plate exhibited the highest hardness value. Microscopic investigations showed the significant reductions in the grain size of the targets after the test.