Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 1 of 1
  • Conference Object
    Citation - WoS: 3
    Citation - Scopus: 3
    Performance Assessment of a Near Room Temperature Magnetic Cooling System
    (Elsevier Ltd., 2017) Ekren, Orhan; Yılancı, Ahmet; Ezan, Mehmet Akif; Kara, Salih Murat; Bıyık, Emrah
    In this study, performance of a near room temperature magnetic cooling system was investigated experimentally in terms of temperature span. The current setup has a permanent magnet pairs (0.7 Tesla), a magnetocaloric material (Gadolinium) and a heat transfer fluid (water, ethylene glycol and 10% ethanol-water mixing) furthermore solar energy was used as a power source of liner motion of the magnetic system. The obtained results showed that ethanol-water was the best heat transfer fluid and also that optimum magnetization-demagnetization period for the system was found 10 s. © 2017 The Authors.