Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7148
Browse
Search Results
Now showing 1 - 2 of 2
Article Assessment of the Repeatability of Column Experiments Results on the Example of a Conservative Tracer(Sciendo, 2025) Pietrzak, Damian; Kania, Jaroslaw; Kmiecik, Ewa; Baba, AlperMost studies on the behavior of pollutants in the groundwater environment are carried out in laboratories, and the results are then implemented at local and regional levels using model simulations or analytical solutions. Column experiments are used to determine the transport characteristics of inorganic and organic chemicals in the soil and water environment. Although column experiments have been conducted regularly for many years, there is currently no established standard protocol for setting up and conducting them to ensure consistent results. The repeatability of column experiments was evaluated for soils, which differ primarily in the silt and clay content, using a conservative tracer susceptible only to advection and dispersion processes to reduce the number of variables affecting the results of the study which arise in a case of using reactive contaminants. The column experiments performed according to the adopted methodology are characterized by high repeatability of the obtained test results for the transport parameters, regardless of the type of injection or the chosen column length (only a small-scale effect is visible). Based on the results, it can be noticed that for the same soil the values of the pore-water velocity for different types of injections and column lengths are very similar. The percentage difference between the values of pore-water velocity obtained for both tested soils does not exceed 5% and for individual pairs of parallel column experiments it does not exceed 3%.Article Citation - WoS: 1Citation - Scopus: 1Optimized Lithium(I) Recovery From Geothermal Brine of Germencik, Türkiye, Utilizing an Aminomethyl Phosphonic Acid Chelating Resin(Taylor and Francis Ltd., 2025) Recepoğlu, Y.K.This study investigates the performance of Lewatit TP 260 ion exchange resin for the efficient recovery of lithium (Li(I)) from geothermal water sourced from the Germencik Geothermal Power Plant in Türkiye. A series of batch sorption experiments were performed to evaluate the influence of key parameters, including resin dosage, solution pH, temperature, initial Li(I) concentration, and contact time, on the Li(I) recovery process. The optimal conditions were determined to be a resin dose of 0.5 g per 25 mL of geothermal water, pH in the range of 6–8, and a temperature of 25°C. Under these conditions, the resin achieved a maximum Li(I) recovery rate of 71% from the geothermal water. Sorption isotherms were further analyzed using the Langmuir, Freundlich, and Dubinin-Radushkevich (D-R) models. Among these, the Langmuir model provided the best fit (R² = 0.9841), suggesting a maximum sorption capacity (qm) of 4.31 mg/g. Continuous recovery experiments conducted in column mode confirmed the practical applicability of Lewatit TP 260, achieving a total sorption capacity of 0.41 mg Li(I)/mL resin. The findings exhibit the potential of this resin as a viable sorbent for sustainable Li(I) extraction from geothermal brines, supporting the development of green energy technologies and contributing to the circular economy. © 2024 Taylor & Francis Group, LLC.
