Master Degree / Yüksek Lisans Tezleri

Permanent URI for this collectionhttps://hdl.handle.net/11147/3008

Browse

Search Results

Now showing 1 - 2 of 2
  • Master Thesis
    Optimization of Energy Consumption and Thermal Comfort in Historic Buildings: Case Study of İzmir National Library Building, Türkiye
    (01. Izmir Institute of Technology, 2023) Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of Architecture
    The 'library,' as a building type, is the visiting space of researchers and storage space of wisdom of past and present thinkers. Historic libraries host unique pieces of cultural heritage such as books, manuscripts, documents, maps, artifacts, paintings, sculptures, and frescos from the previous generations. The thesis aims to reduce energy consumption and improve occupants' comfort while paying attention to degradation risks of paper-based collections in the historic İzmir National Library Building, Türkiye. Thus, it examines building retrofit actions with different impact criteria and conducts the optimization tool to define the most optimal ones. First, three degradation risk assessment procedures were determined for the paper-based collections of the İzmir National Library Building. Within the scope of the thesis, the library building was monitored between 01.10.2016 - 01.10.2017. According to the results of the monitoring process, mechanical, chemical and biological degradation risk analyzes were carried out. The digital simulation model of İzmir National Library was prepared in DesignBuilder v. 7.0.0.102 software and calibrated monthly for a year via hourly air temperature data. Three retrofit optimization scenarios, i.e. neutral, low and high risk impact criteria, were defined by grouping different design variables such as glazing type, exterior door material, pitched roof floor construction, exterior wall construction, heating set point and cooling set point of HVAC system. The objective of optimization was reducing energy consumption and discomfort hours at the same time. The simulation results showed that all three retrofit actions reduced energy consumption and discomfort hours. Scenario 3 was the most successful among other scenarios, providing energy savings by 26.6% and reducing discomfort hours by 80.3%, according to the base case. Besides, there was no significant change in the degradation risk analyzes according to the base case.
  • Master Thesis
    Optimization of Hvac Control Strategies by Building Management Systems Case Study: Özdilek Shopping Center
    (Izmir Institute of Technology, 2003) Canbay, Çağlar Selçuk; Gökçen Akkurt, Gülden; Gökçen Akkurt, Gülden; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    HVAC systems in buildings must be complemented with a good control scheme to maintain comfort under any load conditions. Efficient HVAC control is often the most costeffective option to improve the energy efficiency of a building. However, HVAC processes are nonlinear, and characteristics change on a seasonal basis so the effect of changing the control strategy is usually difficult to predict.Aim of this thesis is to reduce energy consumptions by defining new HVAC control strategies and tuning control loops in Ozdilek Shopping Center "OSC". To investigate the potential for energy savings and to redefine control scenarios, an energy audit was carried out in "OSC". According to these studies new strategies are implemented by the help of existing building management system "BMS" without making any investment.Performance indices were calculated and compared with the accepted standards. Then normalized performance indices are calculated to reach out a better understanding of the buildings' efficiency.