Civil Engineering / İnşaat Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/13
Browse
9 results
Search Results
Article Citation - WoS: 4Citation - Scopus: 15Effects of Seismic Activity on Groundwater Level and Geothermal Systems in İzmir, Western Anatolia, Turkey: the Case Study From October 30, 2020 Samos Earthquake(TÜBİTAK - Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, 2021) Uzelli, Taygun; Bilgiç, Esra; Öztürk, Bahadır; Baba, Alper; Sözbilir, Hasan; Tatar, OrhanThe October 30, 2020 Samos earthquake (Mw 6.6) affected the Aegean Sea and environs, caused destruction and loss of life in the city of İzmir located 70 km away from the earthquake epicenter. Before this earthquake, water resources were monitored in the areas of Bayraklı, Gülbahçe, and Seferihisar. For this purpose, 10 groundwater monitoring wells were drilled in the Bayraklı area, where groundwater level, temperature, and electrical conductivity changes were monitored at 1-h intervals in 5 wells. Besides physical parameters such as groundwater levels, temperatures and electrical conductivities, hydrogeochemical cations, and anions measured in the study area. Change in the groundwater levels was observed before, during, and after the Samos earthquake. A trend of rising groundwater level was observed two days before the mainshock, to a height of 10 cm, and the level was maintained till the end of the earthquake. The water levels returned to its original height after about 7 to 10 days of the earthquake. Moreover, electrical conductivity (EC) values were changed because of the interaction with the surrounding rocks and well walls, mixing with different waters during the earthquake shaking. The essential anomalies were observed in the geothermal fields of Gülbahçe and Seferihisar. Due to this earthquake, new geothermal springs emerged along the NE-SW trending Gülbahçe and Tuzla faults, located about 50 to 20 km from the Samos earthquake epicenter, respectively. The new geothermal waters are in Na-Cl composition and similar to other geothermal springs in the region. While the recorded water temperatures in the new geothermal springs vary from 40 to 45 °C in Seferihisar, it was measured between 35 and 40 °C in Gülbahçe. Due to these anomalies, it is found essential to monitor the effect of the earthquake on the physical and chemical characteristics of the groundwater and its usefulness in earthquake predictions.Article Citation - WoS: 32Citation - Scopus: 35Distribution of Geothermal Arsenic in Relation To Geothermal Play Types: a Global Review and Case Study From the Anatolian Plate (turkey)(Elsevier, 2021) Baba, Alper; Uzelli, Taygun; Sözbilir, HasanArsenic has a natural cycle as it travels underground. It can mix with geothermal fluid in different ways under the control of magmatic and tectonic processes. Geogenic arsenic is present in many geothermal fields in the world at concentrations above the limits set for human health. The arsenic content of geothermal fluids is also related to the concept of geothermal play type, which forms geothermal systems, because the natural processes that form the geothermal system also control the arsenic cycle. In this study, an attempt is made to explain the relationship between the geothermal play type concept and geothermal arsenic circulation. For this purpose, geothermal field examples are given from around the world and Turkey. The result shows that arsenic concentrations can reach significant levels along with plate tectonic boundaries in the world. When arsenic concentrations were evaluated, the effect of major faults on the Anatolian Plate was clearly seen. Also, in the Anatolian plate where volcanosedimentary units are common, geothermal fluids caused more effective alteration along with structural control and increased arsenic concentrations in geothermal systems. This interaction between structural elements, geothermal fluid, and the arsenic cycle shows that the concept of play type in geothermal systems should also be taken into consideration. It was determined that the places with high arsenic values are located within the convective-non-magmatic extensional geothermal play types such as Western Anatolian Extensional System and the North Anatolian Fault. The concept of play type in geothermal systems includes all systematic and external factors that make up these processes. For this reason, it is very important to evaluate the play type classification together with the arsenic cycle.Conference Object Structural Controls on Gülbahçe Geothermal System and Its Hydrogeochemical Properties (western Turkey)(Muğla Sıtkı Koçman Üniversitesi, 2014) Uzelli, Taygun; Mungan, Gamze Gül; Baba, Alper; Sözbilir, HasanGülbahçe Geothermal Field (GGF) is located in eastern parts of the Karaburun Peninsula and is about 45 km away from the city of Izmir, Turkey. The stratigraphy around the GGF is represented by a Miocene volcano-sedimentary succession, including several sedimentary and volcanic units. These units overlie the basement rocks of the Karaburun Platform Carbonates and Bornova Flysch Zone which consists of carbonate blocks embedded in sandstone and mudstone alternations. GGF is located on the Gülbahçe Fault Zone, and are composed of series of NW-SE to NE-SW trending faults, extending from Sığacık Bay to Gülbahçe Bay. While most of the geothermal systems in western Turkey are controlled by normal faults, geothermal systems at the Gülbahçe are controlled by NE/NW-trending strike-slip faults and NE/NW-trending oblique-slip normal faults. An association of these active faults accommodating deep circulation of hydrothermal fluids of sea water origin is the primary control mechanisms of geothermal systems of Gülbahçe.Conference Object Evidence for Sea Water Intrusion in Karstic Aquifer of Karaburun Peninsula, Nw Turkey(International Water Association, 2017) Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Murathan, Alim; Sözbilir, HasanKarstic aquifers are considered to be significant sources of groundwater and are mostly under threat due to sea water intrusion in many parts of the world. Seawater intrusion is also a common problem on karstic aquifers of Karaburun Peninsula in north of Mediterranean Region. The hydrogeology of Karaburun Peninsula is fairly complex and is mostly characterized by highly permeable karstic formations with significant water storage in an otherwise water scarce area. The karstic aquifers of the region were recently found to be under severe salt water intrusion, which significantly altered the position of fresh water/sea water interface as a result of excessive pumping and fault zones controlling the karstic network.Conference Object Investigation of sea water intrusion in the Ildırı Region (Çeşme-Turkey) coastal aquifer(Nevşehir Hacı Bektaş Veli Üniversitesi, 2017) Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Murathan, Alim; Sözbilir, HasanCoastal aquifers are considered to be significant sources of groundwater and are mostly under threat due to sea water intrusion as a result of anthropogenic (i.e., over exploitation, reduced recharge due to climate change, etc.) and natural sources (i.e., tectonic features and fault line orientations) in many parts of the world. Seawater intrusion is also a common problem on coastal aquifers of Turkey.Conference Object Investigation of Sea Water Intrusion in Coastal Aquifers: a Case Study From Karaburun Peninsula, Turkey(The International Association for Hydro-Environment Engineering and Research (IAHR), 2015) Baba, Alper; Şimşek, Celalettin; Gündüz, Orhan; Elçi, Alper; Murathan, Alim; Sözbilir, HasanGroundwater is an important natural resource; as of today, more than 2 billion people depend on groundwater. Determination of the quantity of available water resources is crucial due to continuously increasing water demand and unequal spatial distribution of water in the world. Coastal areas are typically considered to be areas of limited supply and large demand and groundwater is mostly the resource that is used for water supply purposes for coastal communities. Thus, there exist numerous studies in literature that focus on the determination of the groundwater characteristics in coastal regions with particular emphasis on the geological, hydrogeological and hydrochemical properties of coastal groundwater. Coastal aquifers are considered to be significant water resources and are mostly under threat due to salt water intrusion. The reason for salt water intrusion is mostly anthropogenic such as over exploitation but occasionally natural causes like tectonic boundaries or fault lines could be influential. When coupled with low recharge rates that are common in semi-arid regions such as the Mediterranean, effective and sustainable supply of water with sufficient quality and quantity becomes a real challenge for coastal communities.Article Citation - WoS: 20Citation - Scopus: 22Modeling of Seawater Intrusion in a Coastal Aquifer of Karaburun Peninsula, Western Turkey(Springer Verlag, 2017) Mansour, Ahmed Y. S.; Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Murathan, Alim; Sözbilir, HasanSeawater intrusion is a major problem to freshwater resources especially in coastal areas where fresh groundwater is surrounded and could be easily influenced by seawater. This study presents the development of a conceptual and numerical model for the coastal aquifer of Karareis region (Karaburun Peninsula) in the western part of Turkey. The study also presents the interpretation and the analysis of the time series data of groundwater levels recorded by data loggers. The SEAWAT model is used in this study to solve the density-dependent flow field and seawater intrusion in the coastal aquifer that is under excessive pumping particularly during summer months. The model was calibrated using the average values of a 1-year dataset and further verified by the average values of another year. Five potential scenarios were analyzed to understand the effects of pumping and climate change on groundwater levels and the extent of seawater intrusion in the next 10 years. The result of the analysis demonstrated high levels of electrical conductivity and chloride along the coastal part of the study area. As a result of the numerical model, seawater intrusion is simulated to move about 420 m toward the land in the next 10 years under “increased pumping” scenario, while a slight change in water level and TDS concentrations was observed in “climate change” scenario. Results also revealed that a reduction in the pumping rate from Karareis wells will be necessary to protect fresh groundwater from contamination by seawater.Article Citation - WoS: 26Citation - Scopus: 25Conceptual Model of the Gülbahçe Geothermal System, Western Anatolia, Turkey: Based on Structural and Hydrogeochemical Data(Elsevier Ltd., 2017) Uzelli, Taygun; Baba, Alper; Mungan, Gamze Gül; Dirik, Ramazan Kadir; Sözbilir, HasanThe Gülbahçe Geothermal Field is located on the eastern margin of the Karaburun Peninsula, about 45 km from the city of İzmir, western Anatolia, Turkey. The stratigraphy of the study area is represented by a Miocene volcano-sedimentary succession, including several sedimentary and volcanic units. These units overlie the basement rocks of the Karaburun Platform and Bornova Flysch Zone which consist of sandstones, shales and carbonate blocks. These rock units are cut and deformed by a series of NW-SE- to NE-SW-trending faults, extending from Sığacık Bay to Gülbahçe Bay. Structural studies suggest that while most of the geothermal systems in western Anatolia are controlled by normal faults, the geothermal system at Gülbahçe is controlled by a strike-slip dominated shear zone, previously named the İzmir-Balıkesir Transfer Zone. Along the fault zone, associations of active fault segments accommodate deep circulation of hydrothermally modified sea water, and thus the resulting negative flower structure is the primary control mechanism for the geothermal system. Hydrogeochemical properties of the field show that surface temperature of fluid ranges from 30 to 34 °C. Geothermal fluids in Gülbahçe have high salinity (EC > 34 mS/cm) and low enthalpy. Piper and Schoeller diagrams indicate that geothermal fluid is in the NaCl facies. Chemical geothermometers suggest that the reservoir temperature is around 53–136 °C. The isotopic data (oxygen-18, deuterium and tritium) suggest that geothermal fluids are formed by local recharge and deep circulation of sea water.Conference Object Citation - Scopus: 4High Arsenic Levels in Groundwater Resources of Gediz Graben, Western Turkey(CRC Press, 2016) Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Sözbilir, Hasan; Murathan, AlimGediz Graben situated in western Turkey is an area containing extensional structures with active tectonics and geothermal systems that serves as a suitable environment for the presence of high levels of arsenic (As) in groundwater. The results of a comprehensive monitoring program in the basin revealed that the maximum As concentration detected during the monitoring program was 3086 ppb and the average value was calculated to be 23.63 ppb. In addition, As levels in 28% of the water samples were above the 10 ppb limit value making them unsuitable for drinking water supply. These high As concentrations in the basin was mostly associated with long detention times of water in altered rocks located along detachment faults, strong water–rock interaction processes in the alteration zones and anthropogenic influences made within the geothermal fluid reservoir. © 2016 Taylor & Francis Group, London.
