Civil Engineering / İnşaat Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/13
Browse
5 results
Search Results
Article Citation - WoS: 4Citation - Scopus: 15Effects of Seismic Activity on Groundwater Level and Geothermal Systems in İzmir, Western Anatolia, Turkey: the Case Study From October 30, 2020 Samos Earthquake(TÜBİTAK - Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, 2021) Uzelli, Taygun; Bilgiç, Esra; Öztürk, Bahadır; Baba, Alper; Sözbilir, Hasan; Tatar, OrhanThe October 30, 2020 Samos earthquake (Mw 6.6) affected the Aegean Sea and environs, caused destruction and loss of life in the city of İzmir located 70 km away from the earthquake epicenter. Before this earthquake, water resources were monitored in the areas of Bayraklı, Gülbahçe, and Seferihisar. For this purpose, 10 groundwater monitoring wells were drilled in the Bayraklı area, where groundwater level, temperature, and electrical conductivity changes were monitored at 1-h intervals in 5 wells. Besides physical parameters such as groundwater levels, temperatures and electrical conductivities, hydrogeochemical cations, and anions measured in the study area. Change in the groundwater levels was observed before, during, and after the Samos earthquake. A trend of rising groundwater level was observed two days before the mainshock, to a height of 10 cm, and the level was maintained till the end of the earthquake. The water levels returned to its original height after about 7 to 10 days of the earthquake. Moreover, electrical conductivity (EC) values were changed because of the interaction with the surrounding rocks and well walls, mixing with different waters during the earthquake shaking. The essential anomalies were observed in the geothermal fields of Gülbahçe and Seferihisar. Due to this earthquake, new geothermal springs emerged along the NE-SW trending Gülbahçe and Tuzla faults, located about 50 to 20 km from the Samos earthquake epicenter, respectively. The new geothermal waters are in Na-Cl composition and similar to other geothermal springs in the region. While the recorded water temperatures in the new geothermal springs vary from 40 to 45 °C in Seferihisar, it was measured between 35 and 40 °C in Gülbahçe. Due to these anomalies, it is found essential to monitor the effect of the earthquake on the physical and chemical characteristics of the groundwater and its usefulness in earthquake predictions.Article Citation - WoS: 32Citation - Scopus: 35Distribution of Geothermal Arsenic in Relation To Geothermal Play Types: a Global Review and Case Study From the Anatolian Plate (turkey)(Elsevier, 2021) Baba, Alper; Uzelli, Taygun; Sözbilir, HasanArsenic has a natural cycle as it travels underground. It can mix with geothermal fluid in different ways under the control of magmatic and tectonic processes. Geogenic arsenic is present in many geothermal fields in the world at concentrations above the limits set for human health. The arsenic content of geothermal fluids is also related to the concept of geothermal play type, which forms geothermal systems, because the natural processes that form the geothermal system also control the arsenic cycle. In this study, an attempt is made to explain the relationship between the geothermal play type concept and geothermal arsenic circulation. For this purpose, geothermal field examples are given from around the world and Turkey. The result shows that arsenic concentrations can reach significant levels along with plate tectonic boundaries in the world. When arsenic concentrations were evaluated, the effect of major faults on the Anatolian Plate was clearly seen. Also, in the Anatolian plate where volcanosedimentary units are common, geothermal fluids caused more effective alteration along with structural control and increased arsenic concentrations in geothermal systems. This interaction between structural elements, geothermal fluid, and the arsenic cycle shows that the concept of play type in geothermal systems should also be taken into consideration. It was determined that the places with high arsenic values are located within the convective-non-magmatic extensional geothermal play types such as Western Anatolian Extensional System and the North Anatolian Fault. The concept of play type in geothermal systems includes all systematic and external factors that make up these processes. For this reason, it is very important to evaluate the play type classification together with the arsenic cycle.Article Citation - WoS: 20Citation - Scopus: 22Modeling of Seawater Intrusion in a Coastal Aquifer of Karaburun Peninsula, Western Turkey(Springer Verlag, 2017) Mansour, Ahmed Y. S.; Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Murathan, Alim; Sözbilir, HasanSeawater intrusion is a major problem to freshwater resources especially in coastal areas where fresh groundwater is surrounded and could be easily influenced by seawater. This study presents the development of a conceptual and numerical model for the coastal aquifer of Karareis region (Karaburun Peninsula) in the western part of Turkey. The study also presents the interpretation and the analysis of the time series data of groundwater levels recorded by data loggers. The SEAWAT model is used in this study to solve the density-dependent flow field and seawater intrusion in the coastal aquifer that is under excessive pumping particularly during summer months. The model was calibrated using the average values of a 1-year dataset and further verified by the average values of another year. Five potential scenarios were analyzed to understand the effects of pumping and climate change on groundwater levels and the extent of seawater intrusion in the next 10 years. The result of the analysis demonstrated high levels of electrical conductivity and chloride along the coastal part of the study area. As a result of the numerical model, seawater intrusion is simulated to move about 420 m toward the land in the next 10 years under “increased pumping” scenario, while a slight change in water level and TDS concentrations was observed in “climate change” scenario. Results also revealed that a reduction in the pumping rate from Karareis wells will be necessary to protect fresh groundwater from contamination by seawater.Article Citation - WoS: 26Citation - Scopus: 25Conceptual Model of the Gülbahçe Geothermal System, Western Anatolia, Turkey: Based on Structural and Hydrogeochemical Data(Elsevier Ltd., 2017) Uzelli, Taygun; Baba, Alper; Mungan, Gamze Gül; Dirik, Ramazan Kadir; Sözbilir, HasanThe Gülbahçe Geothermal Field is located on the eastern margin of the Karaburun Peninsula, about 45 km from the city of İzmir, western Anatolia, Turkey. The stratigraphy of the study area is represented by a Miocene volcano-sedimentary succession, including several sedimentary and volcanic units. These units overlie the basement rocks of the Karaburun Platform and Bornova Flysch Zone which consist of sandstones, shales and carbonate blocks. These rock units are cut and deformed by a series of NW-SE- to NE-SW-trending faults, extending from Sığacık Bay to Gülbahçe Bay. Structural studies suggest that while most of the geothermal systems in western Anatolia are controlled by normal faults, the geothermal system at Gülbahçe is controlled by a strike-slip dominated shear zone, previously named the İzmir-Balıkesir Transfer Zone. Along the fault zone, associations of active fault segments accommodate deep circulation of hydrothermally modified sea water, and thus the resulting negative flower structure is the primary control mechanism for the geothermal system. Hydrogeochemical properties of the field show that surface temperature of fluid ranges from 30 to 34 °C. Geothermal fluids in Gülbahçe have high salinity (EC > 34 mS/cm) and low enthalpy. Piper and Schoeller diagrams indicate that geothermal fluid is in the NaCl facies. Chemical geothermometers suggest that the reservoir temperature is around 53–136 °C. The isotopic data (oxygen-18, deuterium and tritium) suggest that geothermal fluids are formed by local recharge and deep circulation of sea water.Conference Object Citation - Scopus: 4High Arsenic Levels in Groundwater Resources of Gediz Graben, Western Turkey(CRC Press, 2016) Baba, Alper; Gündüz, Orhan; Şimşek, Celalettin; Elçi, Alper; Sözbilir, Hasan; Murathan, AlimGediz Graben situated in western Turkey is an area containing extensional structures with active tectonics and geothermal systems that serves as a suitable environment for the presence of high levels of arsenic (As) in groundwater. The results of a comprehensive monitoring program in the basin revealed that the maximum As concentration detected during the monitoring program was 3086 ppb and the average value was calculated to be 23.63 ppb. In addition, As levels in 28% of the water samples were above the 10 ppb limit value making them unsuitable for drinking water supply. These high As concentrations in the basin was mostly associated with long detention times of water in altered rocks located along detachment faults, strong water–rock interaction processes in the alteration zones and anthropogenic influences made within the geothermal fluid reservoir. © 2016 Taylor & Francis Group, London.
