Civil Engineering / İnşaat Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/13

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 1
    Citation - Scopus: 1
    Groundwater Recharge Estiaton in the Alaşehir Sub-Basin Using Hydro-Geochemical Data; Alaşehir Case Study
    (Springer, 2021) Tonkul, Serhat; Baba, Alper; Şimşek, Celalettin; Demirkesen, Ali Can
    The issue of groundwater recharge has gained importance in countries where there is not enough water supply to the aquifer. However, groundwater recharge is a difficult parameter to determine. This difficulty stems from factors such as the location of the area to be studied, time, cost, and hydrological data. Numerical, isotope, and chemical approaches are used in groundwater recharge investigations. Numerical and chemical approaches are more costly and time-consuming than chemical approaches. This study aims to ascertain alluvial aquifer recharge in Alaehir (Manisa) sub-basin using chemical approaches (Chloride Mass Balance Method) and its applicability. For this purpose, research wells were drilled at 25 different points in the alluvial aquifer, water sampling was done in wet and dry periods, and rainwater water samples were collected. Groundwater recharge was calculated by using chemical approaches from the chloride concentrations of the water samples collected. An annual average of 74.84 mm of recharge was found in the Alaehir sub-basin. This value corresponds to 16.38% of annual rainfall. At the same time, it was examined the groundwater and geothermal mixing mechanism to demonstrate the applicability of the Chloride Mass Balance Method. It was concluded that geothermal fluid in Alaehir sub-basin mixed with groundwater at a rate of 17%.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 6
    Testing the Performance of Various Polymeric Antiscalants for Mitigation of Sb-Rich Precipitates Mimicking Stibnite-Based Geothermal Deposits
    (Hindawi Publishing Corporation, 2020) Çiftçi, Celal; Karaburun, Emre; Tonkul, Serhat; Baba, Alper; Demir, Mustafa Muammer; Yeşilnacar, Mehmet İrfan
    Scaling is frequently observed in geothermal fields and reduces the energy harvesting of power plants. Recently, Sb-rich deposits have developed in many fields around the world. Various polymeric macromolecules have been used as antiscalants to mitigate the formation of scale. Testing potential commercial antiscalants in field conditions is a tedious and costly process. The artificial synthesis of geothermal deposits in the lab is a more practical and economical way to test the performance of antiscalants. This study obtained a Sb-rich deposit by refluxing SbCl3 and Na2S center dot 3H(2)O in 18 h. The product was found to be a mixture of Sb2O3 and Sb2S3. We examined the performance of antiscalants such as poly(ethylene glycol), poly(vinyl pyrrolidone), Gelatin, and poly(vinyl alcohol) of various molecular weights at 5 to 100 ppm. The formation of Sb2S3 is suppressed in the presence of the polymeric antiscalants. The dosage was found to be critical for the solubilization of Sb-rich deposits. Gelatin of 5 ppm showed the highest performance under the conditions employed in this study. While low dosages improve the concentration of [Sb3+], high dosages are required to increase the solubility of [S2-]. Moreover, the amount of deposit is reduced by 12.4% compared to the reference (in the absence of any polymeric molecules). Thus, comparatively, Gelatin shows the most promising performance among the molecules employed.