Civil Engineering / İnşaat Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/13
Browse
2 results
Search Results
Conference Object Citation - WoS: 1Development of a Proper Mix-Design for Impact Loading of Deflection Hardening Hybrid Fiber Reinforced Concrete(Springer Verlag, 2018) Alami, Muhammad Musa; Erdem, Tahir Kemal; Yardımcı, Mert Yücel; Aydın, SerdarThis study aims to develop a low-cost Hybrid Fiber Reinforced Concrete (HyFRC) that exhibits deflection hardening behavior under bending and has high energy absorption capacity under impact loading by determining proper combination of steel and polyvinyl alcohol (PVA) fibers. More than forty mixtures were prepared including two mixtures of conventional concrete, six mixtures of Engineered Cementitious Composites (ECC), and thirty-six mixtures of HyFRC. The design parameters were chosen as fly ash to cement ratio (1.2, 1.7 and 2.2), steel fiber type and amount (0.5%, 0.75%, and 1.25% by volume), PVA fiber amount (0.25% and 0.50% by volume), and maximum aggregate size (Dmax) of 8 mm and 16 mm. Several tests were carried out on fresh and hardened specimens such as bending, compression, and low-velocity flexural impact loading. Based on the results, it is found that the mixture with 0.75% steel fiber and 0.25% PVA showed the best performance for the aim of the study.Book Part Citation - Scopus: 1Hybrid Control of a 3-D Structure by Using Semi-Active Dampers(Springer Verlag, 2014) Turan, GürsoyA base isolated three storey 3-D building is semi-actively controlled not to exceed the maximum allowable base displacement. Large displacements are likely to cause failure in the isolation system, and hence, failure in the superstructure is expected. If a base isolated structure is positioned next to a very long fault line, such as the North Anatolian Fault, the structure will mostly undergo far field type excitations. Near field effects will be seen less occasionally, but design considerations should be made to account for both types of excitations. In case of nearby seismic action, the isolated building should be smart enough to modify its isolation impedance to resist against large ground displacement and velocities. For this study, an isolated three storey building model together with four dampers, which are all placed at the base level, is considered. The dampers have controllable orifices (damping coefficients) and the magnitudes of these damping coefficients are assigned by using a linear quadratic regulator (LQR). During an earthquake excitation, the storey displacements and velocities are used as feedback in the calculation of the optimal control force that is producible by viscous dampers, at each time step. This force, however, is applied only at times when critical displacements and/or velocities occur. The performance of the set of controllers is presented via time simulations of the system for three recorded earthquakes. In addition, these records are time shifted five folds to see the effect of near field action. The results indicate that the control effectively reduces the maximum displacements of the isolation system, while maintaining a reasonable isolation to the superstructure.
