Civil Engineering / İnşaat Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/13

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 3
    Citation - Scopus: 5
    Helenistik Kulelerde Yanal Yüke İlişkin Düzlem İçi ve Düzlem Dışı Duvar Davranışının Duvar Profilleri ve Açıklık Düzenlerine Bağlı Olarak İncelenmesi
    (Gazi Üniversitesi, 2020) Gençer, Funda; Turan, Mine; Aktaş, Engin
    Dry masonry wall profiles constructed without using bonding material between blocks are encountered in different building types dated to Greek, Hellenistic and Roman periods. Depending on development of earthquake experiences, dry masonry wall profiles vary in terms of wall thickness, number of layers, relationship of layers and size, form, organization and relationship of blocks. In this study, the construction details increasing the structural strength in watch towers constructed in Hellenistic Period are aimed to be determined. This study is limited with investigation of effect of wall profiles and opening organizations on in-plane and out-of-plane wall behaviors under lateral loading. Primarily, wall profiles and opening types of dry masonry towers in ancient Caria, Pamphylia and Cilicia regions, that have not lost authenticity and integrity or had information about their authentic form, were documented. By using gathered data, hypothetic towers with different wall profiles and opening types are designed. To determine in-plane and out-of-plane wall behavior of hypothetic towers, simulation of quasi-static tilt analysis based on equilibrium were carried out, and form changes at walls and collapse angles of towers were identified. Wall profile and opening properties effecting on structural strength under lateral loading were determinedd.
  • Article
    Citation - WoS: 1
    Citation - Scopus: 2
    Consolidation of a Bath Ruin in an Archaeological Site
    (Taylor and Francis Ltd., 2022) Durmuşlar, Feyza; Turan, Mine; Yücetürk, Kutay; Aktaş, Engin
    The study has focused on consolidation of a historical bath ruin in an archaeological site. Cevher Pasa Bath, which is located in Tabae archaeological site in Denizli, Turkey and dated to the 15th century, presents structural problems. The aim of the study is to propose a framework for planning consolidation of the ruins of Cevher Pasa Bath so that conservation work regarding similar masonry ruins in archaeological sites can be guided. Thus, methods of architectural restoration and civil engineering are combined in an interdisciplinary scope. Provision of temporary shoring as an emergency intervention, consolidation and presentation of the ruin within the scope of an interdisciplinary restoration project, and monitoring of the asset within the frame of a monument management plan are suggested, respectively. Structural analysis considering stress and overturning moment checks are performed. Consolidation work includes only supporting of arch remains. Some walls of the ruin are weaker than other parts. These parts need further detailed analysis, and if necessary, further consolidation and strengthening are to be carried out. The monument management plan points out the necessity of collaboration of local and central administrations, and also non-governmental organisations.
  • Article
    Citation - WoS: 3
    Citation - Scopus: 3
    Structural Vulnerability of Ancient Dry Masonry Towers Under Lateral Loading
    (Elsevier, 2020) Gençer, Funda; Hamamcıoğlu Turan, Mine; Turan, Mine; Aktaş, Engin; Aktaş, Engin
    Understanding how the original characteristics contribute to the structural behaviour of antique structures should be the initial stage of planning for conservation work. This study aims to identify the structural behaviour of dry masonry towers under lateral loadings, so that the decision-making process when determining their restoration can be adequately supported. Dry masonry towers in ancient Caria, Pamphylia, and Cilicia Regions are examined. Each of these three areas have very different seismic characteristics. A hypothetical testing process was designed by combining different characteristics from each of the towers. As a result, the characteristics affecting the structural resistance were determined as; the staggering ratio, the stone depth, the ratio between block length and height, the proportional relationship between height and length, the area, number and position of openings, and the distribution of header stones. These characteristics all interact together to determine the failure mechanism; so, understanding this interaction is critical when considering conservation. © 2020 Elsevier Ltd
  • Article
    Construction Techniques of Hayat Houses: Two Case Studies in the Vicinity of Izmir
    (American Society of Civil Engineers (ASCE), 2019) Turan, Mine; Aktaş, Engin; Mamaklı, Fatma Sezgi; Kaplan, Zişan
    This study aims to contribute to the analytic studies on constructional aspects of the hayat house typology with an eye on its historical evolution for conservation purposes. The method used included a review of the surviving examples of the typology in Izmir and its vicinity and the selection of two intact examples whose structural components are legible: one from the earliest period and the other from the latest period. The examples selected are Kerimaga Konagi in Birgi, odemis, Izmir and a house in Kirkagac, Soma, Manisa. The early example (probably eighteenth century, constructed over the remains of an older house) sustains the traditional box system in its wooden upper story that integrates with the roof. The provision of level differences on the upper floor, the traditional relationship of the sitting level-window design, and masonry base are its authentic features. The late example (probably early twentieth century) presents signs of modernization, such as the establishment of a systematic wooden roof and wall frames in relation to each other, lack of diagonals in the perpendicular wall frame, avoidance of projections, and relatively elongated windows placed at higher positions.
  • Article
    Citation - WoS: 6
    Citation - Scopus: 4
    Conservation-Aimed Evaluation of a Historical Aqueduct in Izmir
    (American Society of Civil Engineers (ASCE), 2019) Mamaklı, Fatma Sezgi; Turan, Mine; Aktaş, Engin; Vardaroğlu, Mustafa
    The seventeenth century was the era in which Izmir became an international commercial center in the eastern Mediterranean. The vizier of the era, Koprulu Fazil Ahmet Pasa, noticed the scarcity of potable water in relation with the increasing population at the center of this harbor city and ordered the construction of an aqueduct on Melez Valley. The Veziraga Aqueduct was constructed in 1674. This article aims to identify historical, architectural, and structural characteristics of the Veziraga Aqueduct so that its heritage values and conservations problems can be understood. The geographical and historical characteristics of the Veziraga Aqueduct are described by taking the effects of site and the sociocultural situation of city into consideration. The architectural characteristics of the aqueduct are prepared by using the site survey data to reveal the current condition and find out the original state. Seismic behavior of the aqueduct is investigated by using two approaches: analytical equivalent static analysis and finite-element analysis. The historical, architectural, and structural characteristics of the Veziraga Aqueduct prove its historical, documentary, and aesthetic values.