Civil Engineering / İnşaat Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/13

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - WoS: 3
    Citation - Scopus: 4
    Cyclic Behavior of Steel I-Beams Modified by a Welded Haunch and Reinforced With Gfrp
    (Techno Press, 2009) Eğilmez, Oğuz Özgür; Alkan, Deniz; Özdemir, Timur
    Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. Reducing the flange-web slendemess ratios (FSR/WSR) of beams is the most effective way in mitigating local member buckling as stipulated in the latest seismic design specifications. However, existing steel moment frame buildings with beams that lack the adequate slendemess ratios set forth for new buildings are vulnerable to local member buckling and thereby system-wise instability prior to reaching the required plastic rotation capacities specified for new buildings. This paper presents results from a research study investigating the cyclic behavior of steel I-beams modified by a welded haunch at the bottom flange and reinforced with glass fiber reinforced polymers at the plastic hinge region. Cantilever I-sections with a triangular haunch at the bottom flange and flange slendemess ratios higher then those stipulated in current design specifications were analyzed under reversed cyclic loading. Beam sections with different depth/width and flange/web slendemess ratios (FSR/WSR) were considered. The effect of GFRP thickness, width, and length on stabilizing plastic local buckling was investigated. The FEA results revealed that the contribution of GFRP strips to mitigation of local buckling increases with increasing depth/width ratio and decreasing FSR and WSR. Provided that the interfacial shear strength of the steel/GFRP bond surface is at least 15 MPa, GFRP reinforcement can enable deep beams with FSR of 8-9 and WSR below - to maintain plastic rotations in the order of 0.02 radians without experiencing any local buckling.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 14
    Seismic Performance of Wide-Beam Infill-Joist Block Rc Frames in Turkey
    (American Society of Civil Engineers (ASCE), 2015) Dönmez, Cemalettin
    Observations after the 2011 Van-Erciş earthquake show that some of the recently constructed reinforced-concrete buildings were either heavily damaged or had collapsed. As a building subtype, wide-beam, infill-joist block reinforced-concrete frames got attention because of their mode of failure. There were several such buildings that failed in strong-column, weak-beam mode. Considering the demand created by the earthquake, structures were not expected to reach their full capacity. The purpose of this study is to review the history and current practice of infill-joist frames in Turkey and to conduct a performance evaluation of infill-joist frames designed per the current earthquake code (2007). Regulations for this building subtype are critically reviewed, and the designer's response to code regulations is discussed. Results indicate that the force-based design approach used in the current code is not always adequate to satisfy the displacement demands. In addition, it is observed that layout, proportioning, and detailing requirements of beam-end regions and beam-column connections do not always warrant ductile behavior as targeted.
  • Conference Object
    Citation - WoS: 9
    Cyclic Testing of Steel I-Beams Reinforced With Gfrp
    (Curran Associates, 2011) Eğilmez, Oğuz Özgür; Yormaz, Doruk
    Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. This threat is especially valid for existing steel moment frame buildings with beams that lack adequate flange/web slenderness ratios. As the use of fiber reinforced polymers (FRP) have increased in strengthening and repair of steel members in recent years, using FRPs in stabilizing local instabilities have also attracted attention. Previous computational studies have shown that longitudinally oriented glass FRP (GFRP) strips may serve to moderately brace beam flanges against the occurrence of local buckling during plastic hinging. An experimental study was conducted at Izmir Institute of Technology investigating the effects of GFRP reinforcement on local buckling behavior of existing steel I-beams with flange slenderness ratios (FSR) exceeding the slenderness limits set forth in current seismic design specifications and modified by a bottom flange triangular welded haunch. Four European HE400AA steel beams with a depth/width ratio of 1.26 and FSR of 11.4 were cyclically loaded up to 4% rotation in a cantilever beam test set-up. Both bare beams and beams with GFRP sheets were tested in order to investigate the contribution of GFRP sheets in mitigating local flange buckling. Different configurations of GFRP sheets were considered. The tests have shown that GFRP reinforcement can moderately mitigate inelastic flange local buckling.