WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7150

Browse

Search Results

Now showing 1 - 10 of 874
  • Article
    Citation - WoS: 1
    Modules Whose Maximal Submodules Have Τ-Supplements
    (Luhansk Taras Shevchenko Natl Univ, 2010) Buyukasik, Engin
    Let R be a ring and tau be a preradical for the category of left R-modules. In this paper, we study on modules whose maximal submodules have tau-supplements. We give some characterizations of these modules interms their certain submodules, so called tau-localsubmodules. For some certain preradicals tau, i.e. tau=delta and idempotent tau, we prove that every maximal submodule of M has a tau-supplement if and only if every cofinite submodule of M has a tau-supplement. For a radical tau onR-Mod, we prove that, forevery R-module every submodule is a tau-supplement if and only if R/tau(R) is semisimple and tau is hereditary
  • Article
    Citation - WoS: 7
    Design Education for Adaptive Reuse
    (Archnet-ijar, 2010) Eyuce, Ozen; Eyuce, Ahmet
    Builtform is subject to various types of obsolences in the course of time. Among these functional obsolesences, taking place as an outcome of ever changing modes of production and consumption, are of crucial importance so far as their fate of existing urban fabric is concerned. Defunct buildings become derelict and often subject to demolition which amounts to the eradication of the collective memory. In this connection the process of adaptive reuse can be defined as the task of adjusting functionally obsolete buildings for new program requirements through building conversion. Adaptive reuse projects entail not only alterations within the boundaries of an existing building envolope but also radical changes/transformations in the space configuration so as to accomodate the new set of functional requirements. Therefore, the development of an architectural design scheme in the light of potentials offered and the constraints imposed by an existing architectural entity is essential. Although adaptive reuse projects require case specific approaches depending on the peculiarities of the original structure three main areas of concern can be discerned during the elaboration of the design scheme. These areas of concerns are the space configuration, tectonic aspects of the context within which the project will be realized. The paper addresses itself to the elucidation of these concern areas and the interrelations with the final scheme.
  • Conference Object
    Imatinib-Induced Apoptosis; a Possible Link To Topoisomerase Enzyme Inhibition
    (Ferrata Storti Foundation, 2010) Baran, Y.; Zencir, Z.; Cakir, Z.; Ozturk, E.; Topcu, Z.
  • Article
    Citation - WoS: 7
    Projektiranje Nasipa Zeljezničkih Pruga Primjenom Neuronskih Mreža
    (Croatian Soc Civil Engineers-hsgi, 2013) Tayfur, Gokmen; Egeli, Isfendiyar
    The main requirement in the design of high-speed railway embankments are low values of total differential settlements. The use of cement stabilized layers in embankments, as compared to non-stabilized layers that are now most often in use, is analysed in the paper. Different cement proportions and different water/cement ratios for stabilized layers are considered. It was established that the use of cement stabilized layers in embankments can greatly reduce thickness of individual layers, while also reducing settlement. The research was conducted using the feed forward neural network.
  • Article
    Citation - WoS: 2
    Impact of Thermal Mass Oriented Measures Over CO2 Emissions of a Thermally Insulated Low-Rise Apartment Building in Izmir, Turkey
    (Selcuk Univ, 2014) Gercek, Mumine; Arsan, Zeynep Durmus
    Climate change has drawn the attention of many researchers and practitioners to focus on the methods to address the challenges in achieving low-carbon buildings and cities and in future developments. Nevertheless, few studies have explored the impacts of thermal mass applications for the lowest carbon emissions of building operational energy consumption. A comparative study of CO2 emissions due to different wall and floor compositions is presented in accordance with their lifespans for a hot-humid climate site. Aim of this study is to examine the relation between the energy oriented operations and carbon emissions of the building. Firstly, an existing low-rise building in Izmir is selected, then modelled in the dynamic simulation model software DesignBuilder v4 by synchronizing drawings with basic operational principles of the program. Furthermore, various influence factors of building envelope thermal characteristics are selected as follows: type, location, thickness and thermal specifications of materials used by keeping thermal conductivity value constant. At the end, the research presents remarkable influence of thermal mass oriented measures on reducing energy demands and carbon footprints.
  • Article
    Citation - WoS: 3
    Citation - Scopus: 3
    A Novel Hybrid Thin Jacketing Method for Seismic Retrofitting of Substandard Reinforced Concrete Columns
    (Elsevier Ltd, 2025) Narlitepe, Furkan; Kian, Nima; Demir, Ugur; Demir, Cem; Ilki, Alper
    This paper introduces a novel hybrid thin jacketing method for seismic strengthening of substandard reinforced concrete (RC) columns for which structural repair mortar along with carbon fiber reinforced polymer (CFRP) and longitudinal steel bars are utilized. The method involves three application phases comprising a) removing the cover concrete, b) re-forming the cover concrete with structural repair mortar just after installing extra longitudinal steel bars c) transverse wrapping of CFRP sheets. The effect of using different types of structural repair mortar and its application process are other test parameters taken into account in this study. To evaluate the efficacy of the proposed method, a comprehensive experimental program was conducted, consisting of six largescale RC column specimens with square and rectangular cross-sections. For all of the specimens tested under a simultaneous constant axial load and reversed cyclic lateral loading, three main properties representing existing substandard RC columns such as a) insufficient transverse reinforcement, b) high axial load ratio (0.75) and, c) relatively high shear force corresponding to moment capacity to shear capacity ratios between 0.60 and 0.80, were considered. The responses of specimens were specified in terms of the lateral load-displacement curves, stiffness variation, ductility ratios, damage progression, and energy dissipation. The experimental results demonstrated that in case the retrofitting method is properly applied, the strengthened columns exhibit satisfactory performance in terms of strength and ductility with a remarkable improvement with respect to the substandard columns. Furthermore, a numerical study was conducted to validate the experimental results by using the OpenSees framework.
  • Article
    Influence of Fluorine on Structural and Electrical Properties of VO2 Thin Films Deposited by Magnetron Sputtering
    (Elsevier Ltd, 2025) Akyurek, Bora; Cantas, Ayten; Demirhan, Yasemin; Ozyuzer, Lutfi; Aygun, Gulnur
    This study investigates whether fluorine-based thermal gel used during electrical measurements of vanadium oxide (VO2) films influences the structural, morphological, or compositional integrity of the films. High-quality VO2 films with a resistance ratio change of about 10(4) for metal-insulator transition were deposited by magnetron sputtering. During electrical characterization, VO2 film was heated from room temperature to similar to 370 K with a fluorine-based thermal gel usage to achieve better heat contact between the film and substrate holder. Structural and chemical properties were assessed through XRD, Raman, XPS, SEM, and energy dispersive spectroscopy imaging. XRD revealed diffraction peaks consistent with monoclinic VO2 confirming that the crystal lattice remains the same although fluorine based thermal gel was used. Raman spectra exhibited vibrational modes indicating that the phonon structure of VO2 was preserved despite fluorine gel usage. XPS results showed only a minor F 1s signal (2.8%) limited only to the film surface. SEM and EDS analyses further confirmed that surface morphology and elemental composition remained belonging to VO2 film. These findings demonstrate that the usage of fluorine-based thermal gel results in only a minimal surface interaction, thereby preserving intrinsic material properties of VO2 and supporting a potential usage for future device fabrication applications.
  • Article
    Citation - Scopus: 1
    Assessing the Density of Wood in Heritage Buildings’ Elements Through Expedited Semi-Destructive Techniques
    (Multidisciplinary Digital Publishing Institute (MDPI), 2025) Henriques, Dulce F.; Sen, Ali Umut; Gomes, Maria da Gloria
    Featured Application The research presented and justified in this text aims to provide agents involved in the conservation and refurbishment of old timber elements in buildings with a correlation table for interpreting the readings obtained with penetration resistance testing equipment.Abstract Historically, wood has been among the main materials used in heritage buildings. However, the species and mechanical properties of these elements are often unknown. This uncertainty complicates safety assessment calculations, aggravated by the natural variability of the wood properties. The aim of this work is to assess the density of wooden elements in service using semi-destructive techniques that retain the integrity of structural elements. This research had two phases. First, penetration resistance tests were carried out on laboratory scale on Pinus sylvestris L. wood samples taken from 18th, 19th, and 20th century heritage buildings in Lisbon, Portugal. Later, a field study was carried out on wooden elements from the same buildings, involving needle penetration, core drilling, and moisture content determination tests. The laboratory test results showed a strong correlation between the needle penetration depth and wood density, with an R2 value of 0.76. The results of the field study indicated that the density estimated by the needle penetration test correlated effectively with the measured density of extracted cores after moisture correction, with an R2 of 0.99. In conclusion, the experimental results confirm that penetration resistance and moisture tests are reliable and practical for estimating wood density under in-service conditions.
  • Article
    Tc-99m Erythromycin Lactobionate Inhalation Scintigraphy in Parenchymal Lung Diseases
    (Elsevier Science inc, 1999) Durak, H; Aktogu, S; Degirmenci, B; Sayit, E; Ertay, T; Dereli, S
    We have investigated Technetium 99m erythromycin lactobionate (Tc 99m EL) clearance from the lungs after inhalation, in the presence of an alveolitis. Eighteen patients (6 sarcoidosis, 7 idiopathic fibrosis, and 5 miliary tuberculosis) were imaged after the patients inhaled 1,110 MBq of Tc 99m EL. Clearance half time for the first 45 min, for 24 h, and retention at 24 h correlated with percentage of lymphocytes in bronchoalveolar lavage fluid (BAL) (r =.729, r =.883, and r =.826, respectively). There was a positive correlation between peripheral penetration (PP) and forced expiratory volume in 1 s (FEV1) (r =.806) and forced vital capacity (FVC) (r =.781). Retention was more marked in sarcoidosis compared with tuberculosis (0.025 < p less than or equal to 0.05). Radioaerosol lung imaging may reflect the pulmonary function impairment in parenchymal lung diseases. Retention of Tc 99m EL may be related to number of BAL cells or presence of a lymphocytic alveolitis. Long residency time of Tc 99m EL in the lungs implies that erythromycin can also be administered by inhalation for therapeutic purposes. NUCL MED BIOL 26;6:695-698, 1999. (C) 1999 Elsevier Science Inc. All rights reserved.
  • Conference Object
    Modeling of Glycolysis
    (Elsevier Science Bv, 2016) Batur, Aysem; Hamamci, Haluk; Buyukkileci (Sahin), Ceylan; Buyukkileci, Ali Oguz