WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
19 results
Search Results
Article Citation - WoS: 22Citation - Scopus: 24Design, Evaluation, and Optimization of an Integrated Proton Exchange Membrane and Double Flash Geothermal Based Organic Rankine Cycle Multi-Generation System Fed by a Biomass-Fueled Gasifier(Elsevier, 2024) Taheri, Muhammad Hadi; Seker, Utku; Akkurt, Gulden Gokcen; Mohammadpourfard, MousaThis study introduces an innovative approach by formulating and evaluating a synergistic biomass-geothermal structure, emphasizing optimized inter-component connections. The research stands out for its thorough analysis of parameter impacts on the system and variables, addressing an unexplored aspect in integrated energy systems. The multi-generation systems are the integration of a combined gasification gas turbine cycle, double flash geothermal cycle, and proton exchange membrane cycle for the generating power and hydrogen. The overall system and its subsystems are studied to explore how the performance of thermodynamics and the total cost rate are influenced by operating parameters. The best operational conditions for both subsystems and the overall system have been determined by analyzing the impact of operating parameters on the thermodynamic behavior and environmental impact through parametric studies. The findings indicate while Sabalan's current efficiency is 16.26 %, the system energy efficiency reached 24.89 % when coupled with other renewable source. To enhance the system's efficiency, a genetics algorithm was utilized to simultaneously optimize the total cost of exergy destruction and investment cost. The outcome of the multi-objective optimization revealed that the exergy efficiency of optimal point for the system is 29.8 % and a total investment cost is 6 (M$/year).Article Citation - WoS: 12Citation - Scopus: 13Integration of Psychological Parameters Into a Thermal Sensation Prediction Model for Intelligent Control of the Hvac Systems(Elsevier, 2023) Turhan, Cihan; Özbey, Mehmet Furkan; Lotfi, Bahram; Gökçen Akkurt, GüldenConventional thermal comfort models take physiological parameters into account on thermal comfort models. On the other hand, psychological behaviors are also proven as a vital parameter which affects the thermal sensation. In the literature, limited studies which combine both physiological and psychological parameters on the thermal sensation models are exist. To this aim, this study develops a novel Thermal Sensation Prediction Model (TSPM) in order to control the HVAC system by considering both parameters. A data-driven TSPM, which includes Fuzzy Logic (FL) model, is developed and coded using Phyton language by the authors. Two physiological parameters (Mean Radiant Temperature and External Temperature) and one psychological parameter (Emotional Intensity Score (EIS) including Vigour, Depression, Tension with total of 32 subscales) are selected as inputs of the model. Besides the physiological parameters which are decided intentionally considering a manual ventilated building property, the most influencing three sub- psychological parameters on thermal sensation are also selected in the study. While the physiological parameters are measured via environmental data loggers, the psychological parameters are collected simultaneously by the Profile of Mood States questionnaire. A total of 1159 students are participated to the questionnaire at a university study hall between 15th of August 2021 and 15th of September 2022. The results showed that the novel model predicted Thermal Sensation Vote (TSV) with an accuracy of 0.92 of R2. The output of this study may help to develop an integrated Heating Ventilating and Air Conditioning (HVAC) system with Artificial Intelligence – enabled Emulators that also includes psychological parameters. © 2023 Elsevier B.V.Article Citation - WoS: 30Citation - Scopus: 30A Novel Data-Driven Model for the Effect of Mood State on Thermal Sensation(MDPI, 2023) Turhan, Cihan; Özbey, Mehmet Furkan; Ceter, Aydın Ege; Gökçen Akkurt, GüldenThermal comfort has an important role in human life, considering that people spend most of their lives in indoor environments. However, the necessity of ensuring the thermal comfort of these people presents an important problem, calculating the thermal comfort accurately. The assessment of thermal comfort has always been problematic, from past to present, and the studies conducted in this field have indicated that there is a gap between thermal comfort and thermal sensation. Although recent studies have shown an effort to take human psychology into account more extensively, these studies just focused on the physiological responses of the human body under psychological disturbances. On the other hand, the mood state of people is one of the most significant parameters of human psychology. Thus, this paper investigated the effect of occupants' mood states on thermal sensation; furthermore, it introduced a novel Mood State Correction Factor (MSCF) to the existing thermal comfort model. To this aim, experiments were conducted at a mixed-mode building in a university between 15 August 2021 and 15 August 2022. Actual Mean Vote (AMV) and Profile of Mood States (POMS) were used to examine the effect of mood state on thermal sensation. The outcomes of this study showed that in the mood states of very pessimistic and very optimistic, the occupants felt warmer than the calculated one and the MSCFs are calculated as -0.125 and -0.114 for the very pessimistic and very optimistic mood states, respectively. It is worth our time to note that the experiments in this study were conducted during the COVID-19 Global Pandemic and the results of this study could differ in different cultural backgrounds.Article Citation - WoS: 15Citation - Scopus: 18An Integrated Decision-Making Framework for Mitigating the Impact of Urban Heat Islands on Energy Consumption and Thermal Comfort of Residential Buildings(MDPI, 2023) Turhan, Cihan; Atalay, Ali Serdar; Gökçen Akkurt, GüldenUrban heat island (UHI) is a zone that is significantly warmer than its surrounding rural zones as a result of human activities and rapid and dense urbanization. Excessive air temperature due to the UHI phenomenon affects the energy performance of buildings and human health and contributes to global warming. Knowing that most of the building energy is consumed by residential buildings, therefore, developing a framework to mitigate the impact of the UHI on residential building energy performance is vital. This study develops an integrated framework that combines hybrid micro-climate and building energy performance simulations and multi-criteria decision-making techniques. As a case study, an urban area is analyzed under the Urban GreenUP project funded by the European Union's Horizon 2020 Programme. Four different strategies to mitigate the UHI effect, including the current situation, changing the low-albedo materials with high-albedo ones, nature-based solutions, and changing building facade materials, are investigated with a micro-climatic simulation tool. Then, the output of the strategies, which is potential air temperature, is used in a dynamic building energy simulation software to obtain energy consumption and thermal comfort data of the residential buildings in the case area. Finally, a multi-criteria decision-making model, using real-life criteria, such as total energy consumption, thermal comfort, capital cost, lifetime and installation flexibility, is used to make a decision for decreasing the UHI effect on residential energy performance of buildings. The results showed that applying NBSs, such as green roofs and changing existing trees with high leaf area density ones, have the highest ranking among all mitigation strategies. The output of this study may help urban planners, architects, and engineers in the decision-making processes during the design phase of urban planning.Article Citation - WoS: 1Citation - Scopus: 1Energy and Exergy Analysis of a Geothermal Energy Sourced Hot-Air Drying System(Inderscience Enterprises, 2023) Helvacı, Hüseyin Utku; Keleş, Nazlı; Gökçen Akkurt, GüldenA geothermal energy-sourced drying system was tested for the thin-layer drying process of tomato slices at air temperatures of 40 degrees C, 50 degrees C and 60? and velocities of 0.5 m/s and 1.5 m/s to investigate system performance in terms of the first and second laws of thermodynamics. The energy and the exergy efficiency of the system were found to be 6.6% and 22.31%. The energy utilisation and energy utilisation ratio were calculated in the range of 1.271 kW-5.102 kW and 9.644%-39.56%, respectively. The exergy destruction, exergy efficiency and improvement potential of the drying chamber varied between 0.0198 kW-0.2621 kW, 59.74%-81.95% and 0.00486 kW-0.07396 kW, respectively.Article Citation - WoS: 7Citation - Scopus: 7Comprehensive Thermoeconomic Study of a New Solar Thermosyphon-Assisted Multigeneration System(Elsevier, 2023) Anamaq, Rasoul Najafi; Khani, Leyla; Mohammadpourfard, Mousa; Heris, Saeed Zeinali; Gökçen Akkurt, GüldenNowadays, due to the global energy crisis, limited reservoirs of fossil fuels, and their negative environmental effects, the use of renewable energy sources and multigeneration systems have become good alternatives for conventional thermodynamic systems. One of these resources, whose technology has developed rapidly in recent years, is the use of solar energy for the simultaneous generation of various products. Therefore, in this research, a multigeneration system with several subsystems is introduced. The proposed system includes a solar energy collector to receive thermal energy, two thermal energy storage tanks, an organic Rankine cycle, and a Kalina cycle to generate electricity, a multi-effect distillation unit to produce fresh water, an electrolyzer to produce hydrogen, as well as heat recovery for hot water and hot air generation. In this multigeneration system, the cooling unit is designed with the help of a thermosyphon. The performance of the proposed system is studied from energy, exergy, environmental, and exergoeconomic viewpoints using Aspen HYSYS and EES software. The obtained results show that due to the addition of the thermosyphon unit to the refrigeration system, the exergy efficiency increases from 55.62% to 70.26%. As a result of this combination, the performance of the whole system is improved and the amount of costs are reduced. In addition, the parabolic collector system has the highest exergy destruction ratio, 39%, among the subsystems. Furthermore, the results of the exergoeconomic analysis indicate that the PEM water heater with 33.3% and the ejector with 22.7% own the highest cost destruction rates.Article Citation - WoS: 49Citation - Scopus: 51Energy, Exergy, Exergoeconomic, and Exergoenvironmental (4e) Analysis of a New Bio-Waste Driven Multigeneration System for Power, Heating, Hydrogen, and Freshwater Production: Modeling and a Case Study in Izmir(Elsevier, 2023) Tabriz, Zahra Hajimohammadi; Mohammadpourfard, Mousa; Gökçen Akkurt, Gülden; Heris, Saeed ZeinaliToday, the world is facing numerous challenges such as the increasing demand for energy, fossil fuels reduction, the growth of atmospheric pollutants, and the water crisis. In the present research, a new multigeneration system based on urban sewage bio-waste has been designed and evaluated for power, hydrogen, freshwater, and heating production. This system, which consists of biomass conversion subsystem, hydrogen production unit, Brayton cycle, atmospheric water harvesting unit, steam Rankine cycle, and organic Rankine cycles, has been evaluated from a thermodynamic point of view, and the energy, exergy, exergoeconomic, and exergoenvironmental analyses have been carried out on it. In the current study, the atmospheric water harvesting unit, as an attractive and environmentally friendly technology, is integrated with this Biomass-based multigeneration. A case study has been conducted on this system using the information collected from cigli wastewater treatment plant located In Izmir province, Turkey, and the results indicate that such a system, in addition to receiving sewage sludge from the treatment plant unit as a polluting waste, can produce added value products. The modeling results show that in the base conditions and with a feed rate of 7.52 kg/s, the total power generated by this system is 17750 kW, the hydrogen production rate is 3180 kg/h, the freshwater production rate is more than 18 l/h, and the energy and exergy efficiencies are 35.48% and 40.18%, respectively. According to the exergoeconomic and exergoenvironmental evaluations, the unit cost of total products and the unit emission of carbon dioxide are calculated as 13.05 $/GJ and 0.2327 t/MWh, respectively. Also, the results of parametric studies show that increasing the rate of Biomass improves the overall energy efficiency and production rates and also reduces the unit emission of carbon dioxide, but on the other hand, it causes a decrease in exergy efficiency and an increase in the unit cost of total products.Article Citation - WoS: 23Citation - Scopus: 27The Influence of Meteorological Parameters on Pm10: a Statistical Analysis of an Urban and Rural Environment in İzmir/Turkiye(MDPI, 2023) Birim, Necmiye Gulin; Turhan, Cihan; Atalay, Ali Serdar; Gökçen Akkurt, GüldenAir pollution is a substantial menace, especially in industrialized urban zones, which affects the balance of the environment, life of vital organisms and human health. Besides the main causes of air pollution such as dense urbanization, poor quality fuels and vehicle emissions, physical environment characteristics play an important role on air quality. Therefore, it is vital to understand the relationship between the characteristics of the natural environment and air quality. This study examines the correlations between the PM10 pollutant data and meteorological parameters such as temperature (T-air), relative humidity (RH), and wind speed (WS) and direction (WD) under the European Union's Horizon 2020 project. Two different zones (Vilayetler Evi as an urban zone and Sasali Natural Life Park as a rural zone) of Izmir Province in Turkiye are used as a case study and the PM10 data is evaluated between 1 January 2017 and 31 December 2021. A one-tailed t-test is used in order to statistically determine the relationships between the PM10 pollutant data and meteorological parameters. As a further study, practical significance of the parameters is investigated via the effect size method and the results show that the RH is found to be the most influencing parameter on the PM10 for both zones, while T-air is found to be statistically non-significant.Article Citation - WoS: 1Citation - Scopus: 1Thermodynamic Re-Assessment of a Geothermal Binary Power Plant Operated in a Moderate-Temperature Geothermal Field(Inderscience, 2023) Özcan, Zeynep; Gökçen Akkurt, GüldenAn existing organic rankine cycle power plant which uses isobutane as working fluid is re-evaluated for different working fluids. The plant is first modelled by EES software; then the model is simulated for different working fluids obtaining heat transferred through the heat exchanger, net work output, energy and exergy efficiencies, and mass flowrate of the working fluid. Two parametric studies are conducted to evaluate the thermodynamic performance of the plant under a range of turbine inlet temperature (130°C–155°C) and geothermal resource temperature (152°C–161°C) for each working fluid. The study reveals that the highest cycle energy and exergy efficiencies are observed for R-152a at any geothermal resource temperature. R-152a resulted with 13.1% and 58.2% cycle energy and exergy efficiency, respectively at operation condition, whilst the lowest efficiency and net work output is calculated under n-butane presence.Article Citation - WoS: 26Citation - Scopus: 25Biomass Driven Polygeneration Systems: a Review of Recent Progress and Future Prospects(Elsevier, 2023) Tabriz, Zahra Hajimohammadi; Khani, Leyla; Mohammadpourfard, Mousa; Gökçen Akkurt, GüldenBiomass is the most widely used renewable energy source which is highly appreciated due to its high availability and non-intermittent nature. Considering problems such as reduction of fossil fuels, global warming, and emission of greenhouse gases, lack of attention to the existing situation may cause irreversible damage to the future of the planet. In addition to using renewable energy sources, improving the efficiency of systems will also be helpful. Polygeneration systems play an important role in increasing efficiency and reducing pollution. So, the use of biomass in polygeneration systems seems to be a great approach for sustainable development. Recent studies on biomass-based polygeneration systems have focused on how to use biomass and integrate diverse subsystems to achieve the best performance from energy and exergy viewpoints. The present paper reviews biomass-based systems, and the parameters affecting the performance of these systems. The literature review shows that the high exergy destruction rate in the gasifiers is the most frequent problem among recent articles. In addition, despite the advantages of anaerobic digestion process, the number of studies conducted on the use of this method for biomass conversion is small. In the end, results, limitations, and future outlooks of these systems are discussed.
