WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
5 results
Search Results
Article Citation - WoS: 5Citation - Scopus: 5Use of Amberlite Xad-7hp for the Separation of Mn(ii) and Mn(vii) in Waters(Pleiades Publishing, 2017) Erdem Yayayürük, Aslı; Eroğlu, Ahmet Emin; Eroğlu, Ahmet Emin; 04.01. Department of Chemistry; 04. Faculty of Science; 01. Izmir Institute of TechnologyA simple method is proposed for the determination and speciation of Mn(II) and Mn(VII) in waters utilizing a macroporous resin, Amberlite XAD-7HP. The batch method was employed and flame atomic absorption spectrometry was used in all determinations. Amberlite XAD-7HP resin was shown to retain Mn(VII) between pH 4 and 12. If the solution contains only one of the species, either Mn(II) or Mn(VII), the resin behaves selectively depending on the pH of the solution. The elution from the sorbent was realized using K2C2O4 in HNO3. The efficiency of the method was checked via spike recovery experiments. The proposed method was successfully applied to industrial wastewater samples and quantitative recoveries (≥96.0%) confirmed the accuracy of the method.Article Citation - WoS: 2Citation - Scopus: 2Sample Collection Into Sterile Vacuum Tubes To Preserve Arsenic Speciation in Natural Water Samples(American Society of Civil Engineers (ASCE), 2013) Baba, Alper; Gürleyük, Hakan; Gündüz, Orhan; Elçi, Alper; Baba, Alper; Şimşek, Celalettin; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyThe accurate speciation analysis of arsenic is a serious concern for water quality monitoring programs. Because the preservation of sample integrity until analysis is one of the most important aspects of speciation, this study aims to compare the performance of four different sample preservation methods under diverse conditions of sample quality. Natural samples with different characteristics were collected into the following containers to study their effectiveness: (1) standard high-density polyethylene bottle with no preservative; (2) empty, sterile Vacuette tube with no preservative; (3) sterile tripotassium ethylenediaminetetraacetic acid (K3EDTA) Vacuette tube with K3EDTA additive; and (4) empty, sterile Vacuette tube with added hydrochloric acid (HCl). Known concentrations of arsenite [As(III)] were also added to each container to monitor the oxidation of As(III) to arsenate [As(V)]. The results revealed recovery ratios exceeding 95% in all containers with sterile vacuum conditions. In particular, the K3EDTA Vacuette tube yielded a recovery very close to 100% of the spiked As(III), which is known to rapidly oxidize to As(V). Overall, collecting the sample into a container under sterile vacuum conditions and using a universally accepted preserving agent such as EDTA or HCl significantly improved the preservation of the original species distribution in the water matrix studied, compared to sampling without the use of preservation methods. After validation by future research, these sterile vacuum tubes can possibly be utilized for collecting and storing samples for the routine speciation analysis of other elements such as selenium, chromium, and antimony.Article Citation - WoS: 36Citation - Scopus: 42Speciated Arsenic Concentrations, Exposure, and Associated Health Risks for Rice and Bulgur(Elsevier Ltd., 2014) Sofuoğlu, Sait Cemil; Güzelkaya, Hilal; Sofuoğlu, Aysun; Kavcar, Pınar; Sofuoğlu, Sait Cemil; Sofuoğlu, Aysun; 03.02. Department of Chemical Engineering; 03.07. Department of Environmental Engineering; 03. Faculty of Engineering; 01. Izmir Institute of TechnologyArsenic species were determined in rice and bulgur samples that were collected from 50 participants who also supplied exposure related information through a questionnaire survey. Speciation analysis was conducted using an HPLC-ICP-MS system. Ingestion exposure to arsenic and associated health risks were assessed by combining the concentration and questionnaire data both for individual participants and the subject population. Inorganic arsenic dominated both in rice and bulgur but concentrations were about an order of magnitude higher in rice (160. ±. 38. ng/g) than in bulgur. Because participants also consumed more rice than bulgur, exposures were significantly higher for rice resulting in carcinogenic risks above acceptable level for 53% and 93% of the participants when the in-effect and the proposed potencies were used, respectively, compared to 0% and 5% for bulgur. An inorganic arsenic standard for rice would be useful to lower the risks while public awareness about the relation between excessive rice consumption and health risks is built, and bulgur consumption is promoted.Article Citation - WoS: 50Synthesis of Aminopropyl Triethoxysilane-Functionalized Silica and Its Application in Speciation Studies of Vanadium(iv) and Vanadium(v)(Elsevier Ltd., 2011) Erdem, Aslı; Shahwan, Talal; Çağır, Ali; Eroğlu, Ahmet Emin; Shahwan, Talal; 04.01. Department of Chemistry; 04. Faculty of Science; 01. Izmir Institute of TechnologyA solid phase extraction sorbent, aminopropyl triethoxysilane-functionalized silica was prepared and used for vanadium speciation prior to inductively coupled plasma mass spectrometric determination. The necessary sorption parameters such as sorption pH, reaction temperature, sorbent amount and sample volume were optimized. The sorption for V(V) and V(IV) under the optimized conditions was 98% (±1) and was lower than 10%, respectively. The sorption process was investigated both from a kinetic perspective and also in terms of Freundlich, Dubinin-Radushkevich and Langmuir isotherm models to characterize the uptake of vanadate ion by the functionalized silica. Desorption from the sorbent was realized with 0.5 mol L−1 thiourea prepared in 0.2 mol L−1 HCl. Among the possible interfering species tested, Te(IV), Se(IV), Se(VI) and Fe(III) showed interference effects with V(V) signal. The validity of the method was first checked via spike recovery experiments with four different types of water; namely ultra pure, bottled drinking, tap, and sea water for different concentrations of V(V). The percent recovery values changed between 87 and 108 for all water types. The accuracy of the proposed methodology was also checked by analyzing a standard reference material (NIST, SRM 1643e) and a good agreement was found between the determined and the certified value. The proposed methodology has also been shown to be applicable for the separate sorption of V(V) in the absence/presence of V(IV) and for the sorption of both V(IV) and V(V) in waters. The amount of V(IV) can then be determined from the difference.Article Citation - WoS: 46Synthesis, Characterization and Application of a Novel Mercapto- and Amine-Bifunctionalized Silica for Speciation/Sorption of Inorganic Arsenic Prior To Inductively Coupled Plasma Mass Spectrometric Determination(Elsevier Ltd., 2011) Shahwan, Talal; Çağır, Ali; Shahwan, Talal; Eroğlu, Ahmet Emin; Çağır, Ali; 04.01. Department of Chemistry; 04. Faculty of Science; 01. Izmir Institute of TechnologyA bifunctional sorbent, (NH2 + SH)silica, containing both amine and mercapto functionalities was prepared by modification of silica gel with 3-(triethoxysilyl)propylamine and (3-mercaptopropyl)trimethoxysilane. In addition to the bifunctional sorbent, silica gel was modified individually with the functional mercapto- and amino-silanes, and the mono-functional sorbents, namely (SH)silica and (NH2)silica, were also mechanically mixed ((NH2)silica + (SH)silica) for the sake of comparison of sorption performances. It has been demonstrated that (SH)silica shows quantitative sorption only to As(III) at two pH values, 1.0 and 9.0, while (NH2)silica displays selectivity only towards As(V) at pH 3.0. On the other hand, the bifunctional (NH2 + SH)silica possesses the efficient features of the two mono-functionalized sorbents; for example, it retains As(III) at a wider pH range, from 1.0 to at least 9.0 with the exception at pH 2.0, and it also shows quantitative sorption to As(V) at pH 3.0. This property gives the bifunctional (NH2 + SH)silica a better flexibility in terms of sorption performance as a function of solution pH. The mechanically mixed (NH2)silica + (SH)silica exhibits a similar but less efficient sorption behavior compared to the bifunctional sorbent. Desorption of both As(III) and As(V) species can be realized using 0.5 M NaOH. The validity of the proposed method was checked through the analysis of a standard reference material and a good correlation was obtained between the certified (26.67 μg L−1) and determined (27.53 ± 0.37 μg L−1) values. Spike recovery tests realized with ultrapure water (93.0 ± 2.3%) and drinking water (86.9 ± 1.2%) also confirmed the applicability of the method.
