WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
5 results
Search Results
Article Citation - WoS: 6Citation - Scopus: 7Engineering Free-Standing Electrospun Pllcl Fibers on Microfluidic Platform for Cell Alignment(Springer Science and Business Media Deutschland GmbH, 2024) Yildirim-Semerci,Ö.; Arslan-Yildiz,A.Here, a PLLCL-on-chip platform was developed by direct electrospinning of poly (L-lactide-co-ε-caprolactone) (PLLCL) on polymethyl methacrylate (PMMA) microfluidic chips. Designed microchip provides the electrospinning of free-standing aligned PLLCL fibers which eliminates limitations of conventional electrospinning. Besides, aligned fiber structure favors cell alignment through contactless manipulation. Average fiber diameter, and fiber alignment was evaluated by SEM analyses, then, leakage profile of microchip was investigated. 3D cell culture studies were conducted using HeLa and NIH-3T3 cells, and nearly 85% cell viability was observed in PLLCL-on-chip for 15 days, while cell viability of 2D control started to decrease after 7 days based on Live dead and Alamar Blue analyses. These findings emphasize biocompatibility of PLLCL-on-chip platform for 3D cell culture and its ability to mimic extracellular matrix (ECM). Immunostaining results prove that PLLCL-on-chip platform favors the secretion of ECM proteins compared to control groups, and cytoskeletons of cells were in aligned orientation in PLLCL-on-chip, while they were in random orientation in control groups. Overall, these results demonstrate that the developed platform is suitable for the formation of various 3D cell culture models and a potential candidate for cell alignment studies. © The Author(s) 2024.Review Citation - WoS: 23Citation - Scopus: 24Microfluidic-Based Technologies for Diagnosis, Prevention, and Treatment of Covid-19: Recent Advances and Future Directions(Springer, 2023) Tarım, Ergün Alperay; Anıl İnevi, Müge; Özkan, İlayda; Keçili, Seren; Bilgi, Eyüp; Başlar, Muhammet Semih; Özçivici, Engin; Öksel Karakuş, Ceyda; Tekin, Hüseyin CumhurThe COVID-19 pandemic has posed significant challenges to existing healthcare systems around the world. The urgent need for the development of diagnostic and therapeutic strategies for COVID-19 has boomed the demand for new technologies that can improve current healthcare approaches, moving towards more advanced, digitalized, personalized, and patient-oriented systems. Microfluidic-based technologies involve the miniaturization of large-scale devices and laboratory-based procedures, enabling complex chemical and biological operations that are conventionally performed at the macro-scale to be carried out on the microscale or less. The advantages microfluidic systems offer such as rapid, low-cost, accurate, and on-site solutions make these tools extremely useful and effective in the fight against COVID-19. In particular, microfluidic-assisted systems are of great interest in different COVID-19-related domains, varying from direct and indirect detection of COVID-19 infections to drug and vaccine discovery and their targeted delivery. Here, we review recent advances in the use of microfluidic platforms to diagnose, treat or prevent COVID-19. We start by summarizing recent microfluidic-based diagnostic solutions applicable to COVID-19. We then highlight the key roles microfluidics play in developing COVID-19 vaccines and testing how vaccine candidates perform, with a focus on RNA-delivery technologies and nano-carriers. Next, microfluidic-based efforts devoted to assessing the efficacy of potential COVID-19 drugs, either repurposed or new, and their targeted delivery to infected sites are summarized. We conclude by providing future perspectives and research directions that are critical to effectively prevent or respond to future pandemics.Article Citation - WoS: 9Citation - Scopus: 9Fabrication and Development of a Microfluidic Paper-Based Immunosorbent Assay Platform (μpisa) for Colorimetric Detection of Hepatitis C(Royal Society of Chemistry, 2023) Özefe, Fatih; Arslan Yıldız, AhuPaper-based microfluidics is an emerging analysis tool used in various applications, especially in point-of-care (PoC) diagnostic applications, due to its advantages over other types of microfluidic devices in terms of simplicity in both production and operation, cost-effectiveness, rapid response time, low sample consumption, biocompatibility, and ease of disposal. Recently, various techniques have been developed and utilized for the fabrication of paper-based microfluidics, such as photolithography, micro-embossing, wax and PDMS printing, etc. In this study, we offer a fabrication methodology for a microfluidic paper-based immunosorbent assay (μPISA) platform and the detection of Hepatitis C Virus (HCV) was carried out to validate this platform. A laser ablation technique was utilized to form hydrophobic barriers easily and rapidly, which was the major advantage of the developed fabrication methodology. The characterization of the μPISA platform was performed in terms of micro-channel properties using bright-field (BF) microscopy, and surface properties using scanning electron microscopy (SEM). At the same time, sample volume and liquid handling capacity were analyzed quantitatively. Ablation speed (S) and laser power (P) were optimized, and it was shown that one combination (10P60S) provided minimal deviation in micro-channel dimensions and prevented deterioration of hydrophobic barriers. Also, the minimum hydrophobic barrier width, which prevents cross-barrier bleeding, was determined to be 255.92 ± 10.01 μm. Furthermore, colorimetric HCV NS3 detection was implemented to optimize and validate the μPISA platform. Here, HCV NS3 in both PBS and human blood plasma was successfully detected by the naked eye at concentrations as low as 1 ng mL−1 and 10 ng mL−1, respectively. Moreover, the limit of detection (LoD) values for HCV NS3 were acquired as 0.796 ng mL−1 in PBS and 2.203 ng mL−1 in human blood plasma with a turnaround time of 90 min. In comparison with conventional ELISA, highly sensitive and rapid HCV NS3 detection was accomplished colorimetrically on the developed μPISA platform.Article Citation - WoS: 8Citation - Scopus: 11Cost-Effective and Rapid Prototyping of Pmma Microfluidic Device Via Polymer-Assisted Bonding(Springer, 2021) Sözmen, Alper Baran; Arslan Yıldız, AhuMicrofluidic systems are relatively new technology field with a constant need of novel and practical manufacturing materials and methods. One of the main shortcomings of current methods is the inability to provide rapid bonding, with high bonding strength, and sound microchannel integrity. Herein we propose a novel method of assembly that overcomes the mentioned limitations. Polymer-assisted bonding is a novel, rapid, simple, and inexpensive method where a polymer is solubilized in a solvent and the constituted solution is used as a bonding agent. In this study, we combined this method with utilization of several phase-changing materials (PCMs) as channel-protective agents. Glauber's salt appeared to be more suitable as a channel-protective agent compared to rest of the salts that have been used in this study. Based on the bonding strength, quality analyses, leakage tests, and SEM imaging, the superior assisting bonding solvent was determined to be dichloromethane with a PMMA concentration of 2.5% (W/V). It showed a bonding strength of 23.794 MPa and a nearly non-visible bonding layer formation of 2.83 mu m in width which is proved by SEM imaging. The said combination of PCM, solvent, and polymer concentration also showed success in leakage tests and an application of micro-droplet generator fabrication. The application was carried out to test the applicability of developed prototyping methodology, which resulted in conclusive outcomes as the droplet generator simulation run in COMSOL Multiphysics version 5.1 software. In conclusion, the developed fabrication method promises simple, rapid, and strong bonding with sharp and clear micro-channel engraving.Article Citation - WoS: 14Citation - Scopus: 15A Portable Microfluidic Platform for Rapid Determination of Microbial Load and Somatic Cell Count in Milk(Springer, 2019) Düven, Gamze; Çetin, Barbaros; Kurtuldu, Hüseyin; Gündüz, Gülten Tiryaki; Tavman, Şebnem; Kışla, DuyguMicrofluidics systems that have been emerged in the last 20years and used for processing the fluid in a microchannel structure at microliter levels are alternative to the conventional methods. The objective of the study is to develop a microfluidic platform for determination of the microbial load and the number of somatic cells in milk. For this purpose, a polydimethylsiloxane (PDMS) chip with a channel size of 300mx60m was produced. Cells/bacteria labeled with fluorescent stain in milk were counted with the proposed microfluidic platform and the results were compared with the reference cell concentration/the bacterial counts by conventional method. It was found that our platform could count somatic and bacterial cells with an accuracy above 80% in 20min run for each analysis. The portable overall platform has an overall dimension of 25x25x25 cm and weighs approximately 9kg.
