WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
4 results
Search Results
Article Citation - WoS: 6Citation - Scopus: 7Magnetotelluric Investigations Over Geothermal Provinces of India: an Overview(TÜBİTAK - Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, 2023) Prabhala, Bhaskhara Venkata Subba Rao; Pachigolla, Venkata Vijaya Kumar; Chandrasekharam, Dornadula; Deshmukh, Vasu; Singh, Ajay KishoreMagnetotelluric (MT) and audio-magnetotelluric (AMT) studies are sensitive to the geothermal fluids filling the faults and/ or fracture zones of the geothermal system. In India, MT/AMT studies have been carried out in NW Himalayas, central, eastern, and western India. In other areas, detailed MT/AMT studies need to be expedited. This review paper presents the art of geothermal exploration in India by using MT/AMT techniques and identifies potential zones that can be exploited for power generation and direct application. Reservoir characteristics, carbon emissions reduction methods, and levelised cost factor are also discussed. © TÜBİTAK.Article Citation - WoS: 1Citation - Scopus: 1Thermodynamic Re-Assessment of a Geothermal Binary Power Plant Operated in a Moderate-Temperature Geothermal Field(Inderscience, 2023) Özcan, Zeynep; Gökçen Akkurt, GüldenAn existing organic rankine cycle power plant which uses isobutane as working fluid is re-evaluated for different working fluids. The plant is first modelled by EES software; then the model is simulated for different working fluids obtaining heat transferred through the heat exchanger, net work output, energy and exergy efficiencies, and mass flowrate of the working fluid. Two parametric studies are conducted to evaluate the thermodynamic performance of the plant under a range of turbine inlet temperature (130°C–155°C) and geothermal resource temperature (152°C–161°C) for each working fluid. The study reveals that the highest cycle energy and exergy efficiencies are observed for R-152a at any geothermal resource temperature. R-152a resulted with 13.1% and 58.2% cycle energy and exergy efficiency, respectively at operation condition, whilst the lowest efficiency and net work output is calculated under n-butane presence.Article Citation - WoS: 23Multiple Regression Analysis of Performance Parameters of a Binary Cycle Geothermal Power Plant(Elsevier Ltd., 2015) Karadas, Murat; Çelik, H. Murat; Serpen, Umran; Toksoy, MacitRegression analysis of a 7.35 MWe existing binary geothermal power plant is conducted using actual plant data to assess the plant performance. The thermo physical properties of geothermal fluid and ambient conditions, which are brine (geothermal water) temperature and flow rate, steam and NCGs (non-condensable gases) flow rates and ambient air temperature, directly affect power generation from a geothermal power plant. Generally, amount of power generated is calculated by deterministic formulations of thermodynamics. However, the data would be probabilistic because inputs may be measured by uncalibrated devices or some parameters may be neglected during the calculation. In these cases, the performance of power plant may be estimated by using regression analysis and then changing of plant performance may be monitored overtime. All measured parameters on DORA-1 Geothermal Power Plant from 2006 to 2012 and 49,411 hourly time series data are used in this study. A review of the available literature indicates this paper is the first study to focus on the prediction of power generation of a geothermal power plant by using multiple linear regression analysis. In this study, annual multiple linear regression models are developed to estimate the performance of a geothermal power plant. These models are tested by using classical assumptions of linear regressions and positive serial autocorrelation is found in all models. Autocorrelations are eliminated by using Orcutt-Cochran method. Although the performance model trends, from 2006 to 2008, are found to be close, the performance status of the plant is generally variable from year to year. According to annual regression models, since 2009, the plant performance started to decline with 270 kW(e) electricity generation capacity. The total degradation of the plant performance reached 760 kW(e) capacity by 2012. (C) 2014 Elsevier Ltd. All rights reserved.Article Citation - WoS: 12Citation - Scopus: 19Effect of Non-Condensable Gases on Geothermal Power Plant Performance. Case Study: Kızıldere Geothermal Power Plant-Turkey(Inderscience Enterprises Ltd., 2008) Gökçen Akkurt, Gülden; Yıldırım, NurdanNon-Condensable Gases (NCGs) are natural components of geothermal fluids, and they are a source of considerable capital and operating costs for power plants. The NCG content of geothermal steam varies over the world from almost zero to as much as 25% (wt). In this work, the influence of NCGs on the thermodynamic performance of geothermal power plants is analysed for various NCG content and turbine inlet temperatures. The results obtained can be useful on the feasibility study of single flash geothermal power plants. Depending on the NCG content of the field, the performance of the power plant can be determined roughly. © 2008, Inderscience Publishers.
